8A-270 ELECTRICAL-BODY AND CHASSIS
RTW38DSH000401
6VE1 rpm
Indication Permissible Range
750 690-770
1,000 900-1,060
2,000 1,820-2,070
3,000 2,820-3,120
4,000 3,820-4,180
5,000 4,820-5,180
6,000 5,820-6,180
7,000 6,820-7,180
RTW38DSH000501
4JH1-TC rpm
Indication Permissible Range
750 690-810
2,000 1,875-2,125
3,000 2,850-3,150
4,000 3,820-4,180
5,000 4,820-5,180
ELECTRICAL-BODY AND CHASSIS 8A-277
140R300007
Thermo Unit Inspection
INSPECTION
Use a circuit tester to measure the thermo unit resistance.
Replace the unit when the result of inspection is found
abnormal.
Temperature
Check
condition 60C
(140F) 115C
(239F)
Resistance
value ()
168 3.5 +2.5
30.9 –2.0
041R300002
Fuel Tank Unit Inspection
Measure the fuel tank unit resistance between the connector
terminals 1
F-2 and 3 F-2 while shifting the float from “E”
to “F” point.
Fuel Tank Resistance
Level Float position
mm Standard resistance
F (B) 217.5 +2.2
17 –0.8
1/2 (A) 105.1 (C24SE,
4JA1-L, 6VE1)
112.8 (4JA1-TC,
4JH1-TC)
45 4.5
E (C) 16.2 120 2.0