Page 433 of 3371
ATC-28
AIR CONDITIONER CONTROL
Revision: August 20072004 QX56
Rear Air Control
REAR TEMPERATURE/MODE DIAL (REAR)
Increases or decreases the rear zone temperature and adjusts the mode simultaneously. FLOOR is full hot
setting, FLOOR/PANEL is warm setting, and PANEL is full cold setting. Operates only with rear fan switch
(front) is in the (R) position.
REAR FAN CONTROL SWITCH (REAR)
When the rear fan switch (front) is in the (R) position, it allows the rear fan switch (rear) to control the blower
motor speed. In any other position (1-4), the rear fan switch (front) controls the rear blower motor speed
regardless of the rear fan switch (rear) position.
LJIA0024E
Page 434 of 3371
AIR CONDITIONER CONTROL
ATC-29
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: August 20072004 QX56
Discharge Air FlowEJS002C0
FRONT
REAR
WJIA0540E
WJIA0528E
WJIA0541E
WJIA0893E
Page 435 of 3371
ATC-30
AIR CONDITIONER CONTROL
Revision: August 20072004 QX56
System Description (Front)EJS002C1
CONTROLS AND THEIR FUNCTIONS
WJIA1680E
WJIA0757E
Page 436 of 3371
AIR CONDITIONER CONTROL
ATC-31
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: August 20072004 QX56
System Description (Rear)EJS002C2
CONTROLS AND THEIR FUNCTIONS
WJIA0623E
WJIA0758E
Page 437 of 3371
ATC-32
AIR CONDITIONER CONTROL
Revision: August 20072004 QX56
CAN Communication System DescriptionEJS002C3
Refer to LAN-5, "CAN COMMUNICATION" .
Page 439 of 3371

ATC-34
TROUBLE DIAGNOSIS
Revision: August 20072004 QX56
DATA MONITOR
Operation Procedure
1. Touch “AIR CONDITIONER” on “SELECT TEST ITEM” screen.
2. Touch “DATA MONITOR” on “SELECT DIAG MODE” screen.
3. Touch either “ALL SIGNALS” or “SELECTION FROM MENU” on
“DATA MONITOR” screen.
4. Touch “START”.
5. When “SELECTION FROM MENU” is selected, touch items to
be monitored. When “ALL SIGNALS” is selected, all the items
will be monitored.
6. Touch “RECORD” while monitoring, then the status of the moni-
tored item can be recorded. To stop recording, touch “STOP”.
Display Item List
WJIA0468E
BCIA0031E
All signals Monitors all the items.
Selection from menu Selects and monitors the individual item selected.
WJIA0469E
Monitor item name “operation or
unit”Contents
IGN ON SW “ON/OFF” Displays “IGN Position (ON)/OFF, ACC Position (OFF)” status as judged from ignition switch signal.
COMP ON SIG “ON/OFF” Displays “COMP (ON)/COMP (OFF)” status as judged from air conditioner switch signal.
FAN ON SIG “ON/OFF” Displays “FAN (ON)/FAN (OFF)” status as judged from blower motor switch signal.
Page 440 of 3371

TROUBLE DIAGNOSIS
ATC-35
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: August 20072004 QX56
How to Perform Trouble Diagnosis for Quick and Accurate RepairEJS002C5
WORK FLOW
SYMPTOM TABLE
*1ATC-56, "Operational Check (Front)"
or AT C - 5 9 , "
Operational Check
(Rear)" .
SHA9 00 E
Symptom Reference Page
A/C system does not come on. Go to Trouble Diagnosis Procedure for A/C System.AT C - 6 0 , "
Power
Supply and
Ground Circuit for
Front Air Control"
A/C system display is malfunctioning. Go to "Navigation System".AV-61, "NAVIGA-
TION SYSTEM"
A/C system cannot be controlled. Go to Self-diagnosis Function.AT C - 5 3 , "
A/C Sys-
tem Self-diagno-
sis Function"
Air outlet does not change.
Go to Trouble Diagnosis Procedure for Mode Door Motor.AT C - 6 3 , "Mode
Door Motor Cir-
cuit"Mode door motor is malfunctioning.
Discharge air temperature does not change.
Go to Trouble Diagnosis Procedure for Air Mix Door Motor.ATC-67, "
Air Mix
Door Motor Cir-
cuit"Air mix door motor is malfunctioning.
Intake door does not change.
Go to Trouble Diagnosis Procedure for Intake Door Motor.ATC-76, "
Intake
Door Motor Cir-
cuit"Intake door motor is malfunctioning.
Defroster door motor is malfunctioning. Go to Trouble Diagnosis Procedure for Defroster Door Motor.AT C - 7 9 ,
"Defroster Door
Motor Circuit"
Front blower motor operation is malfunction-
ing.Go to Trouble Diagnosis Procedure for Front Blower Motor.AT C - 8 3 , "Front
Blower Motor Cir-
cuit"
Rear blower motor operation is malfunction-
ing.Go to Trouble Diagnosis Procedure for Rear Blower Motor.AT C - 9 0 , "Rear
Blower Motor Cir-
cuit"
Rear discharge air temperature and/or air
outlet does not change.Go to Trouble Diagnosis Procedure for Rear Air Control circuit.ATC-101, "Rear
Air Control Circuit"
Magnet clutch does not engage. Go to Trouble Diagnosis Procedure for Magnet Clutch.ATC-104, "Mag-
net Clutch Circuit"
Insufficient cooling Go to Trouble Diagnosis Procedure for Insufficient Cooling.AT C - 11 0 , "Insuffi-
cient Cooling"
Insufficient heating Go to Trouble Diagnosis Procedure for Insufficient Heating.AT C - 11 7 , "Insuffi-
cient Heating"
Noise Go to Trouble Diagnosis Procedure for Noise.ATC-118, "Noise"
Page 456 of 3371

TROUBLE DIAGNOSIS
ATC-51
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: August 20072004 QX56
Front Air Control Terminals and Reference ValueEJS002C9
Measure voltage between each terminal and ground by following
Terminals and Reference Value for Front Air Control.
PIN CONNECTOR TERMINAL LAYOUT
TERMINALS AND REFERENCE VALUE FOR FRONT AIR CONTROL
WJIA0759E
WJIA0402E
Te r m i -
nal No.Wire
colorItemIgnition
switchConditionVoltage (V)
(Approx.)
1 B Ground - - 0V
2YPower supply for each door motor
PBRON - 0 - 5V
3 W/G Air mix door motor (Driver) CW ON Clockwise rotation Battery voltage
4 G Air mix door motor (Driver) CCW ON Counterclockwise rotation Battery voltage
5 BR/W Mode door motor CW ON Clockwise rotation Battery voltage
6 P/L Mode door motor CCW ON Counterclockwise rotation Battery voltage
7 O Intake door motor CCW ON Counterclockwise rotation Battery voltage
8 G/B Intake door motor CW ON Clockwise rotation Battery voltage
9 L/B Intake sensor ON - 0 - 5V
10 L/R Fan ON signal ONFan switch OFF 5V
Fan switch ON 0V
11 Y/B Rear defroster request ON - Battery voltage
12 W/R Compressor ON signal ONA/C switch OFF 5V
A/C switch ON 0V
13 G/R Variable blower control ON - 0 - 5V
14 Y/G Power supply for IGN ON - Battery voltage
15 P Ground for each door motor PBR ON - 0 - 5V
16 GR Mode door motor PBR feedback ON - 0 - 5V
17 P Ambient sensor ON - 0 - 5V
18 SBAir mix door motor (Driver) PBR
feedbackON - 0 - 5V
19 LG Defroster door motor CW ON Clockwise rotation Battery voltage
20 P/B Defroster door motor CCW ON Counterclockwise rotation Battery voltage