BL-48
REMOTE KEYLESS ENTRY SYSTEM
Revision: August 20072004 QX56
Remote keyless entry system turns on interior lamp and ignition keyhole illumination (for 30 seconds) with
input of UNLOCK signal from keyfob.
For detailed description, refer to LT- 1 3 1 , "
ROOM LAMP TIMER OPERATION" .
Panic Alarm Operation
When key switch is OFF (ignition key is not inserted in key cylinder), remote keyless entry system turns on and
off horn and headlamp intermittently with input of PANIC ALARM signal from keyfob.
The alarm automatically turns off after 25 seconds or when BCM receives any signal from keyfob.
Keyless Power Window Down (Open) Operation
When keyfob unlock switch is turned ON with ignition switch OFF, and the switch is detected to be on continu-
ously for 3 seconds, the driver's door and passenger's door power windows are simultaneously opened.
Power window is operated to open and the operation continues as long as the keyfob unlock switch is
pressed.
CAN Communication System DescriptionEIS002RQ
Refer to LAN-5, "CAN COMMUNICATION" .
REMOTE KEYLESS ENTRY SYSTEM
BL-53
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
Terminals and Reference Value for BCMEIS002RT
Te r m i n a l Wire
ColorItem ConditionVoltage (V)
(Approx.)
11 O Ignition switch (ACC or ON) Ignition switch (ACC or ON position) Battery voltage
12 R/L Front door switch RH Door open (ON) → Door close (OFF) Battery voltage → 0
13 GR Rear door switch RH Door open (ON) → Door close (OFF) Battery voltage → 0
18 PRemote keyless entry
receiver ground—0
19 V/WRemote keyless entry
receiver (Power supply)Ignition switch OFF
20 G/WRemote keyless entry
receiver signal (Signal)Stand-by (keyfob buttons released)
When remote keyless entry receiver
receives signal from keyfob (keyfob
buttons pressed)
37 B/RKey switch and key lock sole-
noid (insert)Key inserted in IGN key cylinder (ON)
→ Key removed from IGN key cylinder
(OFF)Battery voltage → 0
38 W/LIgnition switch (ON or
START)Ignition switch (ON or START posi-
tion)Battery voltage
39 W CAN-H — —
40 R CAN-L — —
42 GR Glass hatch ajar switchGlass hatch open (ON) → Glass hatch
close (OFF) 0 → Battery voltage
43 R/BBack door latch (door ajar
switch)Door open (ON) → Door close (OFF) 0 → Battery voltage
47 SB Front door switch LH Door open (ON) → Door close (OFF) 0 → Battery voltage
48 R/Y Rear door switch LH Door open (ON) → Door close (OFF) 0 → Battery voltage
56 R/GBattery saver
(Interior lamp)Battery saver does operated → Does
not operated (ON → OFF)Battery voltage → 0
57 Y/R Battery power supply — Battery voltage
59 GFront door lock assembly LH
(actuator) (unlock)Door lock & unlock switch
(Neutral → Unlock)0 → Battery voltage
60 G/B Turn signal LHWhen doors are locked or unlocked
using keyfob (OFF → ON)
*10 → Battery voltage
61 G/Y Turn signal RHWhen doors are locked or unlocked
using keyfob (OFF → ON)
*10 → Battery voltage
LIIA1893E
LIIA1894E
LIIA1895E
REMOTE KEYLESS ENTRY SYSTEM
BL-55
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
CONSULT-II Function (BCM)EIS002RV
CONSULT-II can display each diagnostic item using the diagnostic test modes shown following.
CONSULT-II Inspection ProcedureEIS002RW
CONSULT-II can display each diagnostic item using the following diagnostic test modes: work support, data
monitor, active test, and CAN diagnostic support monitor through data reception and command transmission
via the BCM communication line.
“MULTI REMOTE ENT”
CAUTION:
If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be
detected in self-diagnosis depending on control unit which carries out CAN communication.
1. Turn ignition switch OFF.
2. Connect CONSULT-II and CONSULT-II CONVERTER to the
data link connector.
3. Turn ignition switch ON.
4. Touch “START (NISSAN BASED VHCL)".
BCM
diagnostic test itemDiagnostic mode Description
Inspection by partWORK SUPPORTSupports inspections and adjustments. Commands are transmitted to the
BCM for setting the status suitable for required operation, input/output sig-
nals are received from the BCM and received date is displayed.
DATA MONITOR Displays BCM input/output data in real time.
ACTIVE TESTOperation of electrical loads can be checked by sending drive signal to
them.
SELF-DIAG RESULTS Displays BCM self-diagnosis results.
CAN DIAG SUPPORT MNTRThe result of transmit/receive diagnosis of CAN communication can be
read.
ECU PART NUMBER BCM part number can be read.
CONFIGURATION Performs BCM configuration read/write functions.
BBIA0369E
BCIA0029E
REMOTE KEYLESS ENTRY SYSTEM
BL-57
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
Active Test
Work Support
CDL UNLOCK SW Indicates [ON/OFF] condition of unlock signal from lock/unlock switch.
CDL LOCK SW Indicates [ON/OFF] condition of lock signal from lock/unlock switch.
DOOR SW-RL Indicates [ON/OFF] condition of rear door switch LH.
DOOR SW-RR Indicates [ON/OFF] condition of rear door switch RH.
RKE LCK-UNLCK Indicates [ON/OFF] condition of lock/unlock signal at the same time from keyfob.
RKE KEEP UNLK Indicates [ON/OFF] condition of unlock signal from keyfob.
TRNK OPN MNTR Indicates [ON/OFF] condition of glass open switch.Monitored Item Description
Test Item Description
FLASHER This test is able to check right and left hazard reminder operation. The right hazard lamp turns on
when “RH” on CONSULT-II screen is touched and the left hazard lamp turns on when "LH" on CON-
SULT-II screen is touched.
POWER WINDOW DOWN This test is able to check power window down operation. The windows are lowered when “ON” on
CONSULT-II screen is touched.
HORN This test is able to check panic alarm and horn reminder operations. The alarm activate for 0.5 sec-
onds after “ON” on CONSULT-II screen is touched.
DOOR LOCK This test is able to check door lock operation. The doors lock and unlock based on the item on CON-
SULT-II screen touched.
TRUNK/BACK DOOR This test is able to check back door actuator operation. The back door is opened when “OPEN” on
CONSULT-II screen is touched.
PSB/PBD OPEN TESTThis test is able to check power back door operation. The power back door is fully opened when
“OPEN” on the CONSULT-II screen is touched if the door operation enable conditions are met.
Test Item Description
REMO CONT ID REGIST Keyfob ID code can be registered.
REMO CONT ID ERASUR Keyfob ID code can be erased.
REMO CONT ID CONFIR It can be checked whether keyfob ID code is registered or not in this mode.
HORN CHIRP SET Horn chirp function mode can be changed in this mode. The function mode will be changed when
"CHANG SETT" on CONSULT-II screen is touched.
HAZARD LAMP SET Hazard lamp function mode can be changed in this mode. The function mode will be changed when
"CHANG SETT" on CONSULT-II screen is touched.
MULTI ANSWER BACK SETHazard and horn reminder mode can be changed in this mode. The reminder mode will be changed
when “CHANG SETT” on CONSULT-II screen is touched.
AUTO LOCK SETAuto locking function mode can be changed in this mode. The function mode will be changed when
"CHANG SETT" on CONSULT-II screen is touched.
PANIC ALRM SETPanic alarm operation mode can be changed in this mode. The operation mode will be changed
when "CHANG SETT" on CONSULT-II screen is touched.
TRUNK OPEN SETBack door opener operation mode can be changed in this mode. The operation mode will be
changed when "CHANG SETT" on CONSULT-II screen is touched.
PW DOWN SETKeyless power window down (open) operation mode can be changed in this mode. The operation
mode will be changed when "CHANG SETT" on CONSULT-II screen is touched.
REMOTE KEYLESS ENTRY SYSTEM
BL-59
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
Trouble Diagnosis ProcedureEIS002RY
1. Check the symptom and customer's requests.
2. Understand outline of system. Refer to BL-45, "
System Description" .
3. Confirm system operation.
Check that the power door lock system operates normally. Refer to BL-16, "POWER DOOR LOCK
SYSTEM" .
Check that the automatic back door system operates normally. Refer to BL-101, "AUTOMATIC BACK
DOOR SYSTEM" .
4. Perform pre-diagnosis inspection. Refer to BL-59, "
BCM Power Supply and Ground Circuit Check" .
5. Refer to trouble diagnosis chart by symptom, repair or replace any malfunctioning parts. Refer to BL-60,
"Trouble Diagnoses" .
6. Inspection End.
BCM Power Supply and Ground Circuit CheckEIS003EF
1. CHECK FUSES AND FUSIBLE LINK
Check the following BCM fuses and fusible link.
NOTE:
Refer to BL-44, "
Component Parts and Harness Connector Location" .
OK or NG
OK >> GO TO 2.
NG >> If fuse is blown, be sure to eliminate cause of problem before installing new fuse, refer to PG-4,
"POWER SUPPLY ROUTING CIRCUIT" .
2. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM.
3. Check voltage between BCM connectors M18, M20 terminals
11, 38, 57, 70 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
Component Parts Terminal No. (SIGNAL) Ampere No. Location
BCM57 (BAT power supply) 15A 22 Fuse block (J/B)
70 (BAT power supply) 50AfFuse and fusible link box
11 (ACC power supply) 10A 4 Fuse block (J/B)
38 (IGN power supply) 10A 59 Fuse and relay box
ConnectorTerminals
(Wire color)
Signal nameIgnition
switchVo l ta g e
(+) (–)
M2070 (W/B)
GroundBattery power
supplyOFFBattery
voltage
57 (Y/R)Battery power
supplyOFFBattery
voltage
M1811 ( O )ACC power
supplyACCBattery
voltage
38 (W/L)IGN power
supplyONBattery
voltage
WIIA0600E
BL-62
REMOTE KEYLESS ENTRY SYSTEM
Revision: August 20072004 QX56
Key Switch (Insert) CheckEIS002S1
1. CHECK KEY SWITCH INPUT SIGNAL
With CONSULT-II
Check key switch "KEY ON SW" in DATA MONITOR mode with CONSULT–II. Refer to BL-27, "
DATA MONI-
TOR" .
When key is inserted to ignition key cylinder:
When key is removed from ignition key cylinder:
Without CONSULT-II
Check voltage between BCM connector M18 terminal 37 and
ground.
OK or NG
OK >> Key switch (insert) circuit is OK.
NG >> GO TO 2.
2. CHECK KEY SWITCH (INSERT)
1. Turn ignition switch OFF.
2. Disconnect key switch and key lock solenoid.
3. Check continuity between key switch terminals 3, 4.
OK or NG
OK >> Repair or replace harness.
NG >> Replace key switch.KEY ON SW : ON
KEY ON SW : OFF
LIIA0169E
ConnectorTerminal
(Wire color)
Condition Voltage (V)
( + ) ( – )
M18 37 (B/R) GroundKey is inserted. Battery voltage
Key is removed. 0
LIIA0567E
Terminals Condition Continuity
3 – 4Key is inserted. Yes
Key is removed. No
LIIA1044E
BL-66
REMOTE KEYLESS ENTRY SYSTEM
Revision: August 20072004 QX56
2. CHECK KEYFOB FUNCTION
With CONSULT-II
Check keyfob function in “DATA MONITOR” mode with CONSULT-II.
When pushing each button of keyfob, the corresponding monitor item should
be turned as follows.
Without CONSULT-II
Check keyfob function using Remote Keyless Entry Tester J-43241.
OK or NG
OK >> WITH CONSULT-II: Keyfob, remote keyless entry receiver and wiring harness between BCM and
remote keyless entry receiver are OK. Replace BCM. Refer to BCS-19, "
Removal and Installation
of BCM" .
OK >> WITHOUT CONSULT-II: Keyfob is OK. Further inspection is necessary. Refer to BL-60, "
Trouble
Diagnoses" .
NG >> WITH CONSULT-II: Further inspection is necessary. Refer to BL-60, "
Trouble Diagnoses" .
NG >> WITHOUT CONSULT-II: Replace keyfob. Refer to BL-71, "
ID Code Entry Procedure" .
Remote Keyless Entry Receiver System CheckEIS005X1
1. REMOTE KEYLESS ENTRY RECEIVER SIGNAL
Check signal voltage waveform between BCM connector M18 termi-
nal 20 and ground using an oscilloscope.
OK or NG
OK >> Remote keyless entry receiver signal power supply, ground and signal circuits are OK. Replace
BCM. Refer to BCS-19, "
Removal and Installation of BCM" .
NG >> GO TO 2.Condition Monitor item
Pushing LOCK KEYLESS LOCK : ON
Pushing UNLOCK KEYLESS UNLOCK : ON
Keep pushing UNLOCKRKE KEEP UNLK
turns to ON 3 seconds
after UNLOCK button
is pushed.
Pushing PANIC KEYLESS PANIC : ON
Pushing LOCK and UNLOCK
at the same timeRKE LCK-UNLCK : ON
Pushing Power Back Door KEYLESS PBD : ON
LIIA1487E
Condition:
Keyfob buttons released : Refer to BL-53, "
Te r m i -
nals and Reference Value
for BCM" .
Keyfob buttons pressed : Refer to BL-53, "
Te r m i -
nals and Reference Value
for BCM" .LIIA1275E
BL-70
REMOTE KEYLESS ENTRY SYSTEM
Revision: August 20072004 QX56
Check Hazard FunctionEIS002S7
1. CHECK HAZARD WARNING LAMP
Does hazard indicator flash with hazard switch?
Ye s o r N o
Yes >> Hazard warning lamp circuit is OK.
No >> Check hazard indicator. Refer to LT- 8 0 , "
TURN SIGNAL AND HAZARD WARNING LAMPS" .
Check Horn FunctionEIS002S8
First, perform the "SELF-DIAG RESULTS" in "BCM" with CONSULT-II, then perform the trouble diagnosis of
malfunction system indicated in "SELF-DIAG RESULTS" of "BCM".
1. CHECK HORN FUNCTION
Does horn sound with horn switch?
Ye s o r N o
Yes >> Horn circuit is OK.
No >> Check horn circuit. Refer to WW-56, "
HORN" .
Check Headlamp FunctionEIS002S9
First, perform the "SELF-DIAG RESULTS" in "BCM" with CONSULT-II, then perform the trouble diagnosis of
malfunction system indicated in "SELF-DIAG RESULTS" of "BCM".
1. CHECK HEADLAMP OPERATION
Does headlamp come on when turning lighting switch ON?
Ye s o r N o
Yes >> Headlamp operation circuit is OK.
No >> Check headlamp circuit. Refer to LT- 6 , "
HEADLAMP (FOR USA)" .
Check Map Lamp Illumination FunctionEIS002SA
1. CHECK MAP LAMP ILLUMINATION FUNCTION
When map lamp switch is in DOOR position, open the front door LH or RH.
OK or NG
OK >> Map lamp illumination circuit is OK.
NG >> Check map lamp illumination circuit. Refer to LT- 1 5 2 , "
ILLUMINATION" . Map lamp and ignition keyhole illumination should illuminate.