Page 512 of 3371

TROUBLE DIAGNOSIS
ATC-107
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: August 20072004 QX56
6. CHECK CIRCUIT CONTINUITY BETWEEN BCM AND FRONT AIR CONTROL
1. Turn ignition switch OFF.
2. Disconnect BCM connector M18 and front air control connector
M49.
3. Check continuity between BCM harness connector M18 terminal
27 (W/R) and front air control harness connector M49 terminal
12 (W/R).
OK or NG
OK >> GO TO 7.
NG >> Repair harness or connector.
7. CHECK VOLTAGE FOR FRONT AIR CONTROL (COMPRESSOR ON SIGNAL)
1. Reconnect BCM connector and front air control connector.
2. Turn ignition switch ON.
3. Check voltage between front air control harness connector M49
terminal 12 (W/R) and ground.
OK or NG
OK >> GO TO 8.
NG-1 >> If the voltage is approx. 5V when A/C switch is ON, replace front air control. Refer to ATC-135,
"FRONT AIR CONTROL" .
NG-2 >> If the voltage is approx. 0V when A/C switch is OFF, replace BCM. Refer to BCS-19, "
Removal
and Installation of BCM" . 27 - 12 Continuity should exist.
WJIA0809E
Te r m i n a l s
ConditionVoltag e
(Approx.) (+)
(-) Front air
control con-
nectorTe r m i n a l N o .
(Wire color)
M49 12 (W/R) GroundA/C switch: ON 0V
A/C switch: OFF 5V
WJIA0449E
Page 513 of 3371

ATC-108
TROUBLE DIAGNOSIS
Revision: August 20072004 QX56
8. CHECK REFRIGERANT PRESSURE SENSOR
WITH CONSULT-II
1. Start engine.
2. Check voltage of refrigerant pressure sensor. Refer to AT C - 3 3 , "
CONSULT-II Function (BCM)" .
WITHOUT CONSULT-II
1. Start engine.
2. Check voltage between ECM harness connector F54 terminal
70 (B/W) and ground.
OK or NG
OK >>WITH CONSULT-II
GO TO 9.
WITHOUT CONSULT-II
GO TO 10.
NG >> Refer to EC-607, "
REFRIGERANT PRESSURE SENSOR" .
9. CHECK BCM INPUT (FAN ON) SIGNAL
Check FAN ON/OFF signal while changing the front switch position.
Refer to ATC-33, "
CONSULT-II Function (BCM)" .
OK or NG
OK >> GO TO 12.
NG >> GO TO 10.
10. CHECK CIRCUIT CONTINUITY BETWEEN BCM AND FRONT AIR CONTROL
1. Turn ignition switch OFF.
2. Disconnect BCM connector M18 and front air control connector
M49.
3. Check continuity between BCM harness connector M18 terminal
28 (L/R) and front air control harness connector M49 terminal 10
(L/R).
OK or NG
OK >> GO TO 11.
NG >> Repair harness or connector.
Te r m i n a l s
Condition Voltage (+)
(-)
ECM con-
nectorTe r m i n a l N o .
(Wire color)
F54 70 (B/W) Ground A/C switch: ON Approx. 0.36 - 3.88V
LJIA0124E
FRONT FAN SWITCH ON : FAN ON SIG ON
FRONT FAN SWITCH OFF : FAN ON SIG OFF
WJIA0469E
28 - 10 Continuity should exist.
WJIA0450E
Page 514 of 3371
TROUBLE DIAGNOSIS
ATC-109
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: August 20072004 QX56
11 . CHECK VOLTAGE FOR FRONT AIR CONTROL (FAN ON SIGNAL)
1. Reconnect BCM connector and front air control connector.
2. Turn ignition switch ON.
3. Check voltage between front air control harness connector M49
terminal 10 (L/R) and ground.
OK or NG
OK >> Check CAN communication. Refer to ATC-32, "CAN Communication System Description" .
NG-1 >> If the voltage is approx. 5V when blower motor is ON, replace front air control. Refer to ATC-135,
"FRONT AIR CONTROL" .
NG-2 >> If the voltage is approx. 0V when blower motor is OFF, replace BCM. Refer to BCS-19, "
Removal
and Installation of BCM" .
Te r m i n a l s
ConditionVo ltag e
(Approx.) (+)
(-)
Front air con-
trol connectorTe r m i n a l N o .
(Wire color)
M49 10 (L/R) GroundA/C switch: ON
Blower motor
operates0V
A/C switch: OFF 5V
WJIA0451E
Page 518 of 3371

TROUBLE DIAGNOSIS
ATC-113
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: August 20072004 QX56
PERFORMANCE CHART
Test Condition
Testing must be performed as follows:
Te s t R e a d i n g
Recirculating-to-discharge Air Temperature Table
Ambient Air Temperature-to-operating Pressure Table
Vehicle location Indoors or in the shade (in a well-ventilated place)
Doors Closed
Door window Open
Hood Open
TEMP. Max. COLD
Mode switch
(Ventilation) set
Recirculation (REC) switch
(Recirculation) set
Fan (blower) speedMax. speed set
Engine speed Idle speed
Operate the air conditioning system for 10 minutes before taking measurements.
Inside air (Recirculating air) at blower assembly inlet
Discharge air temperature at center ventilator
°C (°F) Relative humidity
%Air temperature
°C (°F)
50 - 6020 (68) 5.3 - 6.5 (42 - 44)
25 (77) 9.7 - 11.5 (49 - 53)
30 (86) 13.8 - 16.3 (57 - 61)
35 (95) 18.0 - 21.2 (64 - 70)
40 (104) 22.2 - 25.7 (72 - 78)
60 - 7020 (68) 6.5 - 7.7 (44 - 46)
25 (77) 11.5 - 13.3 (53 - 56)
30 (86) 16.3 - 18.8 (61 - 66)
35 (95) 21.2 - 24.0 (70 - 75)
40 (104) 25.7 - 29.2 (78 - 85)
Ambient air
High-pressure (Discharge side)
kPa (kg/cm
2 , psi)Low-pressure (Suction side)
kPa (kg/cm2 , psi) Relative humidity
%Air temperature
°C (°F)
50 - 7020 (68)680 - 840
(6.94 - 8.57, 98.6 - 121.8)160 - 198
(1.63 - 2.02, 23.2 - 28.7)
25 (77)800 - 985
(8.16 - 10.05, 116.0 - 142.8)198 - 245
(2.02 - 2.50, 28.7 - 35.5)
30 (86)940 - 1,150
(9.59 - 11.73, 136.3 - 166.8)225 - 278
(2.30 - 2.84, 32.6 - 40.3)
35 (95)1,160 - 1,410
(11.83 - 14.38, 168.2 - 204.5)273 - 335
(2.78 - 3.42, 39.6 - 48.6)
40 (104)1,325 - 1,620
(13.52 - 16.52, 192.1 - 234.9)325 - 398
(3.32 - 4.06, 47.1 - 57.7)
Page 521 of 3371

ATC-116
TROUBLE DIAGNOSIS
Revision: August 20072004 QX56
Low-pressure Side Sometimes Becomes Negative
Low-pressure Side Becomes Negative
Gauge indication Refrigerant cycle Probable cause Corrective action
Low-pressure side sometimes
becomes negative.
Air conditioning system
does not function and does
not cyclically cool the com-
partment air.
The system constantly func-
tions for a certain period of
time after compressor is
stopped and restarted.Refrigerant does not dis-
charge cyclically.
↓
Moisture is frozen at expan-
sion valve outlet and inlet.
↓
Water is mixed with refriger-
ant.
Drain water from refrigerant
or replace refrigerant.
Replace liquid tank.
AC354A
Gauge indication Refrigerant cycle Probable cause Corrective action
Low-pressure side becomes nega-
tive.
Liquid tank or front/rear side of
expansion valve′s pipe is
frosted or dewed.High-pressure side is closed
and refrigerant does not flow.
↓
Expansion valve or liquid tank
is frosted.Leave the system at rest until
no frost is present. Start it
again to check whether or not
the malfunction is caused by
water or foreign particles.
If water is the cause, initially
cooling is okay. Then the
water freezes causing a
blockage. Drain water from
refrigerant or replace refrig-
erant.
If due to foreign particles,
remove expansion valve
and remove the particles
with dry and compressed air
(not shop air).
If either of the above meth-
ods cannot correct the mal-
function, replace expansion
valve.
Replace liquid tank.
Check lubricant for contami-
nation.
AC362A
Page 527 of 3371

ATC-122
TROUBLE DIAGNOSIS
Revision: August 20072004 QX56
DIAGNOSTIC PROCEDURE FOR WATER VALVE
1. CHECK WATER VALVE RELAY POWER INPUT CIRCUITS
1. Turn ignition switch OFF.
2. Disconnect water valve relay connector M7.
3. Turn ignition switch ON.
4. Check voltage between water valve relay harness connector ter-
minals and ground.
OK or NG
OK >> GO TO 2.
NG >> Repair harness or connector.
2. CHECK WATER VALVE CONTROL
1. Turn ignition switch ON.
2. Select MAX A/C with mode switch.
3. Check continuity between water valve relay harness connector
M7 terminal 1 (W/G) and ground, as MAX A/C is switched OFF
and ON.
OK or NG
OK >> GO TO 4.
NG >> GO TO 3.
3. CHECK WATER VALVE CONTROL OUTPUT CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect front air control connector M50.
3. Check continuity between water valve relay harness connector
M7 terminal 1 (W/G) and front air control harness connector
M50 terminal 29 (W/G).
4. Check continuity between water valve relay harness connector
M7 terminal 1 (W/G) and ground.
OK or NG
OK >> Replace front air control. Refer to ATC-135, "FRONT AIR CONTROL" .
NG >> Repair harness or connector.
Terminals Ignition switch position
(+)
(-) OFF ON Water valve
relay con-
nectorTe r m i n a l N o .
(Wire color)
M72 (Y/G)
GroundBattery voltage Battery voltage
3 (G/Y) 0V Battery voltage
WJIA0900E
Terminals
Condition Continuity (+)
(-) Water valve
relay con-
nectorTe r m i n a l N o .
(Wire color)
M7 1 (W/G) GroundMAX A/C: ON Yes
MAX A/C: OFF No
WJIA0901E
1 - 29 : Continuity should exist.
1 - Ground : Continuity should not exist.
WJIA0902E
Page 530 of 3371

TROUBLE DIAGNOSIS
ATC-125
C
D
E
F
G
H
I
K
L
MA
B
AT C
Revision: August 20072004 QX56
Ambient Sensor CircuitEJS002CS
COMPONENT DESCRIPTION
Ambient Sensor
The ambient sensor is attached on the radiator core support (left
side). It detects ambient temperature and converts it into a value
which is then input into the front air control.
AMBIENT TEMPERATURE INPUT PROCESS
The front air control includes a processing circuit for the ambient sensor input. However, when the tempera-
ture detected by the ambient sensor increases quickly, the processing circuit retards the front air control func-
tion. It only allows the front air control to recognize an ambient temperature increase of 0.33°C (0.6°F) per 100
seconds.
This prevents constant adjustments due to momentary conditions, such as stopping after high speed driving.
Although the actual ambient temperature has not changed, the temperature detected by the ambient sensor
will increase. This is because the heat from the engine compartment can radiate to the front grille area, loca-
tion of the ambient sensor.
DIAGNOSTIC PROCEDURE FOR AMBIENT SENSOR
SYMPTOM: Ambient sensor circuit is open or shorted. (40 or 41 is
indicated as a result of conducting the front air control self-diagnosis)
1. CHECK VOLTAGE BETWEEN AMBIENT SENSOR AND GROUND
1. Disconnect ambient sensor connector E1.
2. Turn ignition switch ON.
3. Check voltage between ambient sensor harness connector E1
terminal 1 (P) and ground.
OK or NG
OK >> GO TO 2.
NG >> GO TO 4.
WJIA0819E
WJIA0456E
1 - Ground : Approx. 5V
WJIA0966E
Page 547 of 3371

ATC-142
IN-CABIN MICROFILTER
Revision: August 20072004 QX56
IN-CABIN MICROFILTERPFP:27277
Removal and InstallationEJS002D3
FUNCTION
The air inside the passenger compartment is filtered by the in-cabin
microfilters when the heater or A/C controls are set on either the
recirculation or fresh mode. The two in-cabin microfilters are located
in the front heater and cooling unit assembly. The rear heater and
cooling unit assembly only draws in air from the passenger compart-
ment to recirculate into the passenger compartment, so the rear
heater and cooling unit assembly is not equipped with in-cabin
microfilters.
REPLACEMENT TIMING
Replacement of the two in-cabin microfilters is recommended on a regular interval depending on the driving
conditions. Refer to MA-6, "
PERIODIC MAINTENANCE" . It may also be necessary to replace the two in-
cabin microfilters as part of a component replacement if the in-cabin microfilters are damaged.
REPLACEMENT PROCEDURE
1. Remove the two lower glove box hinge pins to remove the glove
box from the instrument panel and let it hang from the cord.
2. Remove the screw and remove the in-cabin microfilter cover.
3. Remove the in-cabin microfilters from the front heater and cool-
ing unit assembly housing.
4. Insert the first new in-cabin microfilter into the front heater and
cooling unit assembly housing and slide it over to the right.
Insert the second new in-cabin microfilter into the front heater
and cooling unit assembly housing.
NOTE:
The in-cabin microfilters are marked with air flow arrows. The
end of the microfilter with the arrow should face the rear of the
vehicle. The arrows should point downward.
LJIA0012E
WLIA0027E
LJIA0134E
LJIA0148E