FRONT FOG LAMP
LT-83
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2004 November 2004 FX35/FX45
Refer to LT-79, "Wiring Diagram — F/FOG —" .
OK or NG
OK >> GO TO 2.
NG >> If fuse is blown, be sure to eliminate cause of malfunction before installing new fuse. Refer to PG-
3, "POWER SUPPLY ROUTING CIRCUIT" .
2. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM connector.
3. Check voltage between BCM harness connector and ground.
OK or NG
OK >> GO TO 3.
NG >> Check harness for open or short between BCM and
fuse.
3. CHECK GROUND CIRCUIT
Check continuity between BCM harness connector and ground.
OK or NG
OK >> INSPECTION END
NG >> Check ground circuit harness.
CONSULT-II FunctionsAKS007CQ
Refer to LT- 1 8 , "CONSULT-II Functions (BCM)" in HEAD LAMP.
Refer to LT- 2 1 , "
CONSULT-II Functions (IPDM E/R)" in HEAD LAMP.
IPDM E/R Battery71
78
88 Unit Power source Fuse and fusible link No.
Terminals Ignition switch position
(+)
(-) OFF ACC ON
ConnectorTerminal
(Wire color)
M311 (LG/R)
Ground0VBattery
voltageBattery
voltage
38 (W/L) 0V 0VBattery
voltage
M442 (L/R)Battery
voltageBattery
voltageBattery
voltage
55 (G)Battery
voltageBattery
voltageBattery
voltage
PKIA5204E
Terminals
Continuity
Connector Terminal (Wire color)
M449 (B)
Ground Yes
52 (B)
PKIA5191E
TURN SIGNAL AND HAZARD WARNING LAMPS
LT-89
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2004 November 2004 FX35/FX45
TURN SIGNAL AND HAZARD WARNING LAMPSPFP:26120
Component Parts and Harness Connector LocationAKS007O6
System DescriptionAKS007CW
OUTLINE
Power is supplied at all times
through 50A fusible link (letter M, located in fuse and fusible link block)
to BCM (body control module) terminal 55
through 15A fuse [No. 22, located in fuse block (J/B)]
to BCM (body control module) terminal 42
through 10A fuse [No. 20, located in fuse block (J/B)]
to rear combination lamp control unit terminal 1
through 10A fuse [No. 19, located in fuse block (J/B)]
to combination meter terminal 8.
TURN SIGNAL OPERATION
When the ignition switch is in the ON or START position, power is supplied
through 15A fuse [No. 1, located in fuse block (J/B)]
to BCM (body control module) terminal 38
through 10A fuse [No. 14, located in fuse block (J/B)]
to combination meter terminal 7.
When the ignition switch is in the ACC or ON position, power is supplied
through 10A fuse [No. 6, located in fuse block (J/B)]
to BCM (body control module) terminal 11.
Ground is supplied
to BCM (body control module) terminals 49 and 52
through grounds M35, M45 and M85
PKIA6523E
LT-90
TURN SIGNAL AND HAZARD WARNING LAMPS
Revision: 2004 November 2004 FX35/FX45
to rear combination lamp control unit terminal 7
through grounds E21, E50 and E51
to combination meter terminals 5, 6 and 15
through grounds M35, M45 and M85.
LH Turn
When the turn signal switch is moved to the left position, BCM output turn signal from BCM terminal 45, inter-
preting it as turn signal is ON.
Connected from BCM terminal 45 to front combination lamp LH terminal 4.
Turn signal lamp turns on
through front combination lamp LH terminal 8
to grounds E21, E50 and E51.
Connected form BCM terminal 45 to rear combination lamp control unit terminal 4.
Rear turn signal (LED) turns on
through rear combination lamp control unit terminal 11
to rear combination lamp LH terminal 3
through rear combination lamp LH terminal 4
to rear combination lamp control unit terminal 10.
BCM sends signal to unified meter and A/C amp. through CAN communication lines, and turns on turn signal
indicator lamp with combination meter.
When rear turn signal lamp (LED) does not turn on, Rear combination lamp control unit sends signal to unified
meter and A/C amp. Unified meter and A/C amp. turn LED burnout status signal to BCM through CAN commu-
nication lines for speeding up turn signal blinking.
RH Turn
When the turn signal switch is moved to the right position, BCM output turn signal from BCM terminal 46, inter-
preting it as turn signal is ON.
Connected from BCM terminal 46 to front combination lamp RH terminal 4.
Turn signal lamp turns on
through front combination lamp RH terminal 8
to grounds E21, E50 and E51.
Connected form BCM terminal 46 to rear combination lamp control unit terminal 5.
Rear turn signal (LED) turns on
through rear combination lamp control unit terminal 9
to rear combination lamp RH terminal 3
through rear combination lamp RH terminal 4
to rear combination lamp control unit terminal 8.
BCM sends signal to unified meter and A/C amp. through CAN communication lines, and turns on turn signal
indicator lamp with combination meter.
When rear turn signal lamp (LED) does not turn on, Rear combination lamp control unit sends signal to unified
meter and A/C amp. Unified meter and A/C amp. turn LED burnout status signal to BCM through CAN commu-
nication lines for speeding up turn signal blinking.
HAZARD LAMP OPERATION
Power is supplied at all times
through 50A fusible link [letter M, located in fuse and fusible link block]
to BCM terminal 55
through 10A fuse [No. 19, located in fuse block (J/B)]
to combination meter terminal 8
through 10A fuse [No. 20, located in fuse block (J/B)]
to rear combination lamp control unit terminal 1.
Ground is supplied
through BCM terminals 49 and 52
to grounds M35, M45 and M85
TURN SIGNAL AND HAZARD WARNING LAMPS
LT-91
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2004 November 2004 FX35/FX45
through rear combination lamp control unit terminal 7
to grounds E21, E50 and E51
through combination meter terminals 5, 6 and 15
to grounds M35, M45 and M85.
When the hazard switch is depressed, ground is supplied
through BCM terminal 29
to hazard switch terminal 2
through hazard switch terminal 1
to grounds M35, M45 and M85.
When the hazard switch is depressed, BCM output turn signal from BCM terminals 45 and 46, interpreting it as
turn signal is ON.
Connected from BCM terminal 45 and 46 to front combination lamp terminal 4.
Turn signal lamp turns on
through front combination lamp terminal 8
to grounds E21, E50 and E51.
Connected form BCM terminals 45 and 46 to rear combination lamp control unit terminals 4 and 5.
Rear turn signal (LED) turns on
through rear combination lamp control unit terminal 11
to rear combination lamp LH terminal 3
through rear combination lamp LH terminal 4
to rear combination lamp control unit terminal 10
through rear combination lamp control unit terminal 9
to rear combination lamp RH terminal 3
through rear combination lamp RH terminal 4
to rear combination lamp control unit terminal 8.
BCM sends signal to unified meter and A/C amp. through CAN communication lines, and turns on turn signal
indicator lamp with combination meter.
When rear turn signal lamp (LED) does not turn on, rear combination lamp control unit sends signal to unified
meter and A/C amp. Unified meter and A/C amp. turn LED burnout status signal to BCM through CAN commu-
nication lines for speeding up turn signal blinking.
REMOTE CONTROL ENTRY SYSTEM OPERATION
Power is supplied at all times
through 50A fusible link [letter M, located in fuse and fusible link block]
to BCM terminal 55
through 10A fuse [No. 19, located in fuse block (J/B)]
to combination meter terminal 8
through 10A fuse [No. 20, located in fuse block (J/B)]
to rear combination lamp control unit terminal 1.
Ground is supplied
to BCM terminals 49 and 52
through grounds M35, M45 and M85
to rear combination lamp control unit terminal 7
through grounds E21, E50 and E51
to combination meter terminals 5, 6 and 15
through grounds M35, M45 and M85.
When the remote control entry system is triggered by input from the keyfob, BCM output turn signal from BCM
terminals 45 and 46, interpreting it as turn signal is ON.
Connected from BCM terminals 45 and 46 to front combination lamp terminal 4,
turn signal lamp turns on
through front combination lamp terminal 8
to grounds E21, E50 and E51.
TURN SIGNAL AND HAZARD WARNING LAMPS
LT-99
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2004 November 2004 FX35/FX45
Preliminary CheckAKS007D3
CHECK POWER SUPPLY AND GROUND CIRCUIT
1. CHECK FUSES
Check fuses for blown-out.
Refer to LT-94, "Wiring Diagram — TURN —" .
OK or NG
OK >> GO TO 2.
NG >> If fuse is blown, be sure to eliminate cause of malfunction before installing new fuse. Refer to PG-
3, "POWER SUPPLY ROUTING CIRCUIT" .
2. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM connector.
3. Check voltage between BCM harness connector and ground.
OK or NG
OK >> GO TO 3.
NG >> Check harness for open or short between BCM and
fuse.
3. CHECK GROUND CIRCUIT
Check continuity between BCM harness connector and ground.
OK or NG
OK >> INSPECTION END
NG >> Check ground circuit harness.
Unit Power source Fuse and fusible link No.
BCMBatteryM
22
Ignition switch ON or START position 1
Ignition switch ACC or ON position 6
Rear combination lamp control unit Battery 20
Terminals Ignition switch position
(+)
(-) OFF ACC ON
ConnectorTerminal
(Wire color)
M311 (LG/R)
Ground0VBattery
voltageBattery
voltage
38 (W/L) 0V 0VBattery
voltage
M442 (L/R)Battery
voltageBattery
voltageBattery
voltage
55 (G)Battery
voltageBattery
voltageBattery
voltage
PKIA5204E
Terminals
Continuity
Connector Terminal (Wire color)
M449 (B)
Ground Yes
52 (B)
PKIA5191E
STOP LAMP
LT-121
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2004 November 2004 FX35/FX45
Stop Lamp Does Not OperateAKS007IJ
1. CHECK TAIL LANP AND TURN SIGNAL LAMP
Make sure tail lamps and turn signal lamps are illuminated.
OK or NG
OK >> GO TO 2.
NG >> GO TO 6.
2. CHECK FUSE
Check fuse No. 20 is blow out.
OK or NG
OK >> GO TO 3.
NG >> If fuse is blow out, be sure to eliminate cause of malfunction before installing new fuse.
3. CHECK INPUT SIGNAL
Check voltage between rear combination lamp control unit harness
connector B65 terminal 3 (P) and ground.
OK or NG
OK >> Replace rear combination lamp control unit.
NG >> GO TO 4.
4. CHECK STOP LAMP SWITCH POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect stop lamp switch connector.
3. Check voltage between stop lamp switch harness connector
E210 terminal 1 (GY) and ground.
OK or NG
OK >> GO TO 5.
NG >> Repair harness or connector.
5. CHECK STOP LAMP SWITCH CIRCUIT
1. Disconnect rear combination lamp control unit connector.
2. Check continuity between stop lamp switch harness connector
E210 terminal 2 (P) and rear combination lamp control unit har-
ness connector B65 terminal 3 (P).
OK or NG
OK >> Replace stop lamp switch.
NG >> Repair harness or connector.
Terminals
(-) Condition Voltage
ConnectorTerminal
(Wire color)
B65 3 (P) GroundStop lamp switch is ON.
(Depressed)Battery voltage
Stop lamp switch is OFF.
(Released)Approx. 0
PKIA5233E
1 (GY) – Ground : Battery voltage should exist.
PKIA5234E
2 (P) – 3 (P) : Continuity should exist.
PKIA5235E
PARKING, LICENSE PLATE AND TAIL LAMPS
LT-127
C
D
E
F
G
H
I
J
L
MA
B
LT
Revision: 2004 November 2004 FX35/FX45
PARKING, LICENSE PLATE AND TAIL LAMPSPFP:26550
Component Parts and Harness Connector LocationAKS007O7
System DescriptionAKS007DT
Control of the parking, license plate, and tail lamp operation is dependent upon the position of the lighting
switch (combination switch). When the lighting switch is placed in the 1ST position, the BCM (body control
module) receives input signal requesting the parking, license plate, side marker and tail lamps to illuminate.
This input signal is communicated to the IPDM E/R (intelligent power distribution module engine room) across
the CAN communication lines. The CPU (central processing unit) of the IPDM E/R (intelligent power distribu-
tion module engine room) controls the tail lamp relay coil. This relay, when energized, directs power to the
parking, license plate, side marker and tail lamps, which then illuminate.
The current that flows by Rear combination lamp unit is controlled, and a tail lamp (LED) is made to turn on.
Power is supplied at all times
through 10A fuse [No. 71, located in IPDM E/R (intelligent power distribution module engine room)]
to tail lamp relay [located in IPDM E/R (intelligent power distribution module engine room)] and
to CPU (central processing unit) [located in IPDM E/R (intelligent power distribution module engine
room)].
through 15A fuse [No. 78, located in IPDM E/R (intelligent power distribution module engine room)]
to CPU (central processing unit) [located in IPDM E/R (intelligent power distribution module engine
room)].
Power is also supplied at all times
through 50A fusible link (letter M, located in the fuse and fusible link block)
to BCM (body control module) terminal 55
through 15A fuse [No. 22, located in fuse block (J/B)]
to BCM (body control module) terminal 42
through 10A fuse [No. 20, located in fuse block (J/B)]
to rear combination lamp control unit terminal 1.
With the ignition switch in the ON or START position, power is supplied
PKIA5272E
LT-128
PARKING, LICENSE PLATE AND TAIL LAMPS
Revision: 2004 November 2004 FX35/FX45
through 15A fuse [No. 1, located in fuse block (J/B)]
to BCM (body control module) terminal 38
through ignition relay [located in IPDM E/R (intelligent power distribution module engine room)]
to CPU (central processing unit) [located in IPDM E/R (intelligent power distribution module engine
room)].
With the ignition switch in the ACC or ON position, power is supplied
through 10A fuse [No. 6, located in fuse block (J/B)]
to BCM (body control module) terminal 11.
Ground is supplied
to BCM (body control module) terminals 49 and 52
through grounds M35, M45 and M85
to IPDM E/R (intelligent power distribution module engine room) terminals 38 and 60
through grounds E21, E50 and E51
to rear combination lamp control unit terminal 7
through grounds E21, E50 and E51.
OPERATION BY LIGHTING SWITCH
With the lighting switch in the 1ST or 2ND position (or if the auto light system is activated), the BCM receives
input signal requesting the parking, license plate, side marker and tail lamps to illuminate. This input signal is
communicated to the IPDM E/R across the CAN communication lines. The CPU in the IPDM E/R controls the
tail lamp relay coil, which when energized, directs power
through IPDM E/R terminal 22
to front side marker lamp LH terminal 1
to clearance lamp LH terminal 2
to license plate lamp LH terminal 1
to rear combination lamp LH terminal 1
to rear combination lamp control unit terminal 2
to front side marker lamp RH terminal 1
to clearance lamp RH terminal 2
to license plate lamp RH terminal 1
to rear combination lamp RH terminal 1.
Ground is supplied at all times
to front side marker lamp LH terminal 2
through grounds E21, E50 and E51
to clearance lamp LH terminal 3
through grounds E21, E50 and E51
to license plate lamp LH terminal 2
through grounds B15 and B45
to rear combination lamp LH terminal 2
through grounds B15 and B45
to front side marker lamp RH terminal 2
through grounds E21, E50 and E51
to clearance lamp RH terminal 3
through grounds E21, E50 and E51
to license plate lamp RH terminal 2
through grounds B15 and B45
to rear combination lamp RH terminal 2
through grounds B203 and B210
to rear combination lamp control unit terminal 7
through grounds E21, E50 and E51.