5A1 – 64IZF 4 HP 16 AUTOMATIC TRANSAXLE
DAEWOO V–121 BL4
DTCDefault Action Indication Description
P1673CAN Receive ECM Mes-
sage FailureMIL ONS The TCM will record operating conditions at he time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
S Adopt Emergency/ Substitute mode and constant 4th
gear by hydraulic control.
S After ignition OFF/ON : 3rd gear by hydraulic control.
Possible P, R and N also possible.
P1839EDS3 Output Shorted To
GroundMIL ONS The TCM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
S Adopt Emergency/Substitute mode and constant 4th
gear by hydraulic control.
S After ignition OFF/ON: 3rd gear by hydraulic control.
Possible P, R and N also possible.
S Power supply cut OFF to the EDS valve.
P1840S EDS3 Output Shorted
To PowerMIL ONS The TCM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
S Adopt Emergency/Substitute mode and constant 4th
gear by hydraulic control.
S After ignition OFF/ON: 3rd gear by hydraulic control.
Possible P, R and N also possible.
S Power supply cut OFF to the EDS valve.
P1841EDS3 Output OpenMIL ONS The TCM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
S Adopt Emergency/Substitute mode and constant 4th
gear by hydraulic control.
S After ignition OFF/ON: 3rd gear by hydraulic control.
Possible P, R and N also possible.
S Power supply cut OFF to the EDS valve.
P1850Solenoid 1 Output Shorted
To GroundMIL ONS The TCM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
S Adopt Emergency/ Substitute mode and constant 4th
gear by hydraulic control.
S After ignition OFF/ON : 3rd gear by hydraulic control.
Possible P, R and N also possible.
P1851Solenoid 1 Output Shorted
To PowerMIL ONS The TCM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
P1852Solenoid 1 Output OpenMIL ONS The TCM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
S Adopt Emergency/ Substitute mode and constant 4th
gear by hydraulic control.
S After ignition OFF/ON : 3rd gear by hydraulic control.
Possible P, R and N also possible.
ZF 4 HP 16 AUTOMATIC TRANSAXLE 5A1 – 65
DAEWOO V–121 BL4
DTCDefault Action Indication Description
P1853Solenoid 2 Output Shorted
To GroundMIL ONS The TCM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
S Adopt Emergency/ Substitute mode and constant 4th
gear by hydraulic control.
S After ignition OFF/ON : 3rd gear by hydraulic control.
Possible P, R and N also possible.
P1854Solenoid 2 Output Shorted
To PowerMIL ONS The TCM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
S Adopt Emergency/ Substitute mode and constant 4th
gear by hydraulic control.
S After ignition OFF/ON : 3rd gear by hydraulic control.
Possible P, R and N also possible.
P1855Solenoid 2 Output OpenMIL ONS The TCM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
S Adopt Emergency/ Substitute mode and constant 4th
gear by hydraulic control.
S After ignition OFF/ON : 3rd gear by hydraulic control.
Possible P, R and N also possible.
P1861S EDS4 Output Shorted
To GroundMIL ONS The TCM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
S Adopt Emergency/Substitute mode and constant 4th
gear by hydraulic control.
S After ignition OFF/ON: 3rd gear by hydraulic control.
Possible P, R and N also possible.
S Power supply cut OFF to the EDS valve.
P1862S EDS4 Output Shorted
To PowerMIL ONS The TCM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
S Adopt Emergency/Substitute mode and constant 4th
gear by hydraulic control.
S After ignition OFF/ON: 3rd gear by hydraulic control.
Possible P, R and N also possible.
S Power supply cut OFF to the EDS valve.
P1863EDS4 Output OpenMIL ONS The TCM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
S Adopt Emergency/Substitute mode and constant 4th
gear by hydraulic control.
S After ignition OFF/ON: 3rd gear by hydraulic control.
Possible P, R and N also possible.
S Power supply cut OFF to the EDS valve.
P1864EDS5 Output Shorted To
GroundMIL ONS The TCM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
S Adopt Emergency/Substitute mode and constant 4th
gear by hydraulic control.
S After ignition OFF/ON: 3rd gear by hydraulic control.
Possible P, R and N also possible.
S Power supply cut OFF to the EDS valve.
5A1 – 66IZF 4 HP 16 AUTOMATIC TRANSAXLE
DAEWOO V–121 BL4
DTCDefault Action Indication Description
P1865EDS5 Output Shorted To
PowerMIL ONS The TCM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
S Adopt Emergency/Substitute mode and constant 4th
gear by hydraulic control.
S After ignition OFF/ON: 3rd gear by hydraulic control.
Possible P, R and N also possible.
S Power supply cut OFF to the EDS valve.
P1866EDS5 Output OpenMIL ONS The TCM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
S Adopt Emergency/Substitute mode and constant 4th
gear by hydraulic control.
S After ignition OFF/ON: 3rd gear by hydraulic control.
Possible P, R and N also possible.
S Power supply cut OFF to the EDS valve.
P1867EDS6 Output Shorted To
GroundMIL ONS The TCM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
S Adopt Emergency/Substitute mode and constant 4th
gear by hydraulic control.
S After ignition OFF/ON: 3rd gear by hydraulic control.
Possible P, R and N also possible.
S Power supply cut OFF to the EDS valve.
P1868S EDS6 Output Shorted
To PowerMIL ONS The TCM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
S Adopt Emergency/Substitute mode and constant 4th
gear by hydraulic control.
S After ignition OFF/ON: 3rd gear by hydraulic control.
Possible P, R and N also possible.
S Power supply cut OFF to the EDS valve.
P1869EDS6 Output OpenMIL ONS The TCM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
S Adopt Emergency/Substitute mode and constant 4th
gear by hydraulic control.
S After ignition OFF/ON: 3rd gear by hydraulic control.
Possible P, R and N also possible.
S Power supply cut OFF to the EDS valve.
P1871S EDS Valve Power Sup-
ply Circuit Shorted To
PowerMIL ONS The TCM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
S Adopt Emergency/Substitute mode and constant 4th
gear by hydraulic control.
S After ignition OFF/ON: 3rd gear by hydraulic control.
Possible P, R and N also possible.
S Power supply cut OFF to the EDS valve.
ZF 4 HP 16 AUTOMATIC TRANSAXLE 5A1 – 67
DAEWOO V–121 BL4
DTCDefault Action Indication Description
P1874S Solenoid Valve Power
Supply Circuit Shorted
To PowerMIL ONS The TCM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
S Adopt Emergency/ Substitute mode and constant 4th
gear by hydraulic control.
S After ignition OFF/ON : 3rd gear by hydraulic control.
Possible P, R and N also possible.
P18812–1 Shift MalfunctionMIL ONS The TCM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
S Adopt Emergency/ Substitute mode and constant 3rd
gear.
S Open lock up clutch.
P1883S 3–2 Shift MalfunctionMIL ONS The TCM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
S Adopt Emergency/ Substitute mode and constant 3rd
gear.
S Open lock up clutch.
P18844–3 Shift MalfunctionMIL ONS The TCM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
S Adopt Emergency/ Substitute mode and constant 4th
gear.
S Open lock up clutch.
P1885S 3–1 Shift MalfunctionMIL ONS The TCM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
S Adopt Emergency/ Substitute mode and constant 3rd
gear.
S Open lock up clutch.
P1886S 4–2 Shift MalfunctionMIL ONS The TCM will record operating conditions at the time
the diagnostic fails. This information will be stored in
the Failure Records buffer.
S Adopt Emergency/ Substitute mode and constant 4th
gear.
S Open lock up clutch.
5A1 – 68IZF 4 HP 16 AUTOMATIC TRANSAXLE
DAEWOO V–121 BL4
DIAGNOSTIC TROUBLE CODE(DTC) P0562
SYSTEM VOLTAGE LOW
Circuit Description
The transaxle control module(TCM) is an electronic de-
vice which monitors inputs to control various transaxle
functions including shift quality and transaxle sensors,
switches, and components to process for use within its’
control program. Based on this input information, the TCM
controls various transaxle output functions and devices.
Conditions For Setting The DTC
S System voltage is less than 8.5 volts.
S Transaxle input voltage is too low.
S Engine speed is greater than 500 rpm.
S Immediately after the above condition occurs.
Action Taken When The DTC Sets
S The Malfunction Indicator Lamp(MIL) will illuminate.
S The TCM will record operating conditions at the
time the diagnostic fails. This information will be
stored in the Failure Records buffer.S Adopt Emergency/ Substitute mode and constant
4th gear by hydraulic control.
S After ignition OFF/ON : 3rd gear by hydraulic con-
trol. Possible P, R and N also possible.
S Power supply cut off to the EDS valve.
Conditions For Clearing The DTC
S The MIL will turn OFF when the malfunction has
not occurred after three–ignition cycle.
S A history DTC will clear after 40 consecutive warm
up cycles without a fault.
S Using a scan tool can clear history DTCs.
Diagnostic Aids
S Inspect the poor wiring harness connection for TCM
connectors and transaxle wiring connectors.
S Inspect the improperly formed or damaged termi-
nals.
ZF 4 HP 16 AUTOMATIC TRANSAXLE 5A1 – 71
DAEWOO V–121 BL4
DIAGNOSTIC TROUBLE CODE(DTC) P0563
SYSTEM VOLTAGE HIGH
Circuit Description
The transaxle control module(TCM) is an electronic de-
vice which monitors inputs to control various transaxle
functions including shift quality and transaxle sensors,
switches, and components to process for use within its’
control program. Based on this input information, the TCM
controls various transaxle output functions and devices.
Conditions For Setting The DTC
S System voltage is greater than 16 volts.
S Transaxle input voltage is too high.
S Immediately after the above condition occurs.
Action Taken When The DTC Sets
S The Malfunction Indicator Lamp(MIL) will illuminate.S The TCM will record operating conditions at the
time the diagnostic fails. This information will be
stored in the Failure Records buffer.
S Adopt Emergency/ Substitute mode and constant
4th gear by hydraulic control.
S After ignition OFF/ON : 3rd gear by hydraulic con-
trol. Possible P, R and N also possible.
S Power supply cut off to the EDS valve.
Conditions For Clearing The MIL/DTC
S The MIL will turn OFF when the malfunction has
not occurred after three–ignition cycle.
S A history DTC will clear after 40 consecutive warm
up cycles without a fault.
S Using a scan tool can clear history DTCs.
5A1 – 74IZF 4 HP 16 AUTOMATIC TRANSAXLE
DAEWOO V–121 BL4
DIAGNOSTIC TROUBLE CODE(DTC) P0601
INTERNAL CONTROL MODULE MEMORY CHECKSUM
ERROR
Circuit Description
A normal function of the Transmission Control Module
(TCM) programming is to perform an internal check that
verifies the integrity of the RAM memory allocations.
The DTC P0601 sets when the Random Access
Memory(RAM) is not operating correctly when checked on
initialization. An area of RAM is failed a read/ write test.
Conditions For Setting The DTC
S The EEPROM checksum test is separated in two
independent parts, the code checksum test and the
calibration checksum test. For each area the check-
sum is calculated and compared with the corre-
sponding checksum valve. If the valves are differ-
ent, the fault will be set.
S System voltage is too high or too low.
S Transaxle input voltage is too high or too low.
S Immediately after the above condition occurs.
Action Taken When The DTC SetsS The Malfunction Indicator Lamp(MIL) will illuminate.
S The TCM will record operating conditions at the
time the diagnostic fails. This information will be
stored in the Failure Records buffer.
S Adopt Emergency/ Substitute mode and constant
4th gear by hydraulic control.
S After ignition OFF/ON : 3rd gear by hydraulic con-
trol. Possible P, R and N also possible.
S Power supply cut off to the EDS valve.
Conditions For Clearing The MIL/DTC
S The MIL will turn OFF when the malfunction has
not occurred after three–ignition cycle.
S A history DTC will clear after 40 consecutive warm
up cycles without a fault.
S Using a scan tool can clear history DTCs.
Diagnostic Aids
S When DTC P0601 sets, the possible cause of fault
could be TCM.
5A1 – 76IZF 4 HP 16 AUTOMATIC TRANSAXLE
DAEWOO V–121 BL4
DIAGNOSTIC TROUBLE CODE(DTC) P0603
INTERNAL CONTROL MODULE KEEP ALIVE
MEMORY(KAM) ERROR
Circuit Description
A normal function of the Transmission Control Module
(TCM) programming is to perform an internal check that
verifies the integrity of the KAM memory allocations.
The DTC P0603 sets when the keep alive memory (KAM)
is not operating correctly when checked on initialization.
An area of KAM is failed a read/ write test.
Conditions For Setting The DTC
S The checksum of the current regulator data will be
tested. If the checksum is not OK, then the error bit
will be set.
S If writing to FLASH during power latch phase failed.
S Each of the flash blocks has its own status which is
located at the beginning of the each flash block and
the status of the FLASH blocks do not fit together.
S System voltage is too high or too low.
S Transaxle input voltage is too high or too low.
S Immediately after the above condition occurs.Action Taken When The DTC Sets
S The Malfunction Indicator Lamp(MIL) will illuminate.
S The TCM will record operating conditions at the
time the diagnostic fails. This information will be
stored in the Failure Records buffer.
S Adopt Emergency/ Substitute mode and constant
4th gear by hydraulic control.
S After ignition OFF/ON : 3rd gear by hydraulic con-
trol. Possible P, R and N also possible.
S Power supply cut off to the EDS valve.
Conditions For Clearing The MIL/DTC
S The MIL will turn OFF when the malfunction has
not occurred after three–ignition cycle.
S A history DTC will clear after 40 consecutive warm
up cycles without a fault.
S Using a scan tool can clear history DTCs.
Diagnostic Aids
S When DTC P0603 sets, the possible cause of fault
could be TCM.