SSANGYONG MUSSO 2003  Service Manual M162 ENGINE COOLING  1D1-9
Removal & Installation Procedure 
1. Drain the coolant. 
2. Disconnect the coolant pump wire connector. 
3. Loosen the hose clip and dsconnect all hoses from thecoolant pump

Page 461 of 1574

SSANGYONG MUSSO 2003  Service Manual 1D1-10  M162 ENGINE COOLING THERMOSTAT
Removal & Installation Procedure 
1. Drain the coolant from the radiator. 
2. Loosen the hose mounting clamp (6) and remove the heaterhose (7).
3. Unscrew the th

Page 462 of 1574

SSANGYONG MUSSO 2003  Service Manual M162 ENGINE COOLING  1D1-11
OIL COOLER PIPE LINE Preceding Work : Removal of upper intake manifold
Tightening  Torque 9 - 11 Nm
1 Upper Intake Manifold 
2 Bolt (M6 X 35, 1 piece)
.....................

Page 466 of 1574

SSANGYONG MUSSO 2003  Service Manual M162 ENGINE COOLING  1D1-15
RADIATOR Preceding Work : Removal of cooling fan shroud
1 Radiator Inlet Coolant Hose 
2 Radiator Outlet Coolant Hose 
3 Make Up Coolant Hose 
4 Automatic Transmission Oil

Page 467 of 1574

SSANGYONG MUSSO 2003  Service Manual 1D1-16  M162 ENGINE COOLING Removal & Installation Procedure1. Drain coolant from the radiator. 
2. Remove the coolant thermo connector from the radiator. 
3. Remove the each coolant hoses.
Tightening

Page 468 of 1574

SSANGYONG MUSSO 2003  Service Manual Circulation Type RadiationCapabilitySECTION 1D2
M161  ENGINE  COOLING
Specifications . . . . . . . . . . . . . . . . . . . . . . .  1D2-1
General  Specifications . . . . . . . . . . . . . . . . .  1D2

Page 469 of 1574

SSANGYONG MUSSO 2003  Service Manual 1D2-2  M161 ENGINE COOLINGFASTENER TIGHTENING SPECIFICATIONS
N

 m
30
22.5 - 27.5
9 - 11 
9 - 11
9 - 11
40.5 - 49.5
3 - 73 - 7
Application
Coolant Drain PlugEngine Hanger Bracket and Coolant Outl

Page 471 of 1574

SSANGYONG MUSSO 2003  Service Manual 1D2-4  M161 ENGINE COOLINGDIAGNOSIS
3. Connect the special tool to the reservoir filler cap and apply 1.4 bar of pressure.
SYSTEM LEAKAGE TEST 
Tools Required 
124 589 15 21 00  Tester 
Test Procedure