Page 505 of 1574
M162 ENGINE ELECTRICAL 1E1-5
3 Fixing Bolt
4 Starting Motor
4. Unscrew the mounting bolts (3) of starting motor.
Installation Notice
5. Remove the starting motor.
6. Installation should follow the removal procedure in the reverse order.
Tightening Torque 35 - 48 Nm
STARTING MOTOR Removal & Installation Procedure
1. Disconnect the ground cable.
2. Unscrew the nut and disconnect the battery cable(1).
Installation Notice
1 Battery Cable
2 Engine Electric Wire
3. Unscrew the nut and disconnect the engine electric wire
(2). Installation Notice
Tightening Torque 12 - 15 Nm
Tightening Torque 6 - 7 Nm
Page 506 of 1574
1E1-6 M162 ENGINE ELECTRICAL
BATTERY
1 Cable Terminal (-)
2 Cable Terminal Cap (-)
3 Cable Terminal Cap (+)
4 Nut
5 Fuseblink Box
6 Terminal (+)7 Battery holddown Bracket
8 Battery Clamp Bolt
9 Battery
10 Sub Tray 11 Battery Tray
Removal & Installation Procedure Notice
Disconnect the battery negative cable first.
Insert the clamp bolt (8) into the battery tray hole (11)
from inside when installing.
Page 510 of 1574

1E1-10 M162 ENGINE ELECTRICAL Functions
1. Firing order : 1-5-3-6-2-4
2. The ignition cables are located on the cylinder head cover.Each ignition coil provides the high voltage to two spark
plugs simultaneously.
- T1/1 : cylinder 2 and 5
- T1/2 : cylinder 3 and 4
- T1/3 : cylinder 1 and 6
Removal & Installation Procedure
1. Disconnect the negative battery cable (1).
2. Remove the ignition cable connector from the ignition cable.
3. Disconnect the secondary spark plug connectors from the each spark plugs and remove the ignition cable. Installation Notice
3. The secondary output voltage (5a) is supplied to the No.2
cylinder spark plug through the spark plug connector. The secondary output voltage (5b) is supplied to the No.5 cylinderspark plug through the ignition cable. The guide pin (W)acts as a ground while the ignition cable is operated.
Make sure that the ignition cables are correctly routed.
Exactly install the ignition cable guide pin into the vehicle
to be grounded.
4. Installation should follow the removal procedure in the reverse order.
Tightening Torque 9 - 11 Nm
Page 512 of 1574