EC-790
[QR (WITHOUT EURO-OBD)]
HO2S1
4. CHECK HO2S1 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between ECM terminal 35 and HO2S1 terminal 2.
Refer to Wiring Diagram.
2. Check harness continuity between ECM terminal 35 or HO2S1 terminal 2 and ground.
Refer to Wiring Diagram.
3. Also check harness for short to power.
OK or NG
OK >> GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK HEATED OXYGEN SENSOR 1
Refer to EC-790, "
Component Inspection" .
OK or NG
OK >> GO TO 6.
NG >> Replace heated oxygen sensor 1.
6. CHECK INTERMITTENT INCIDENT
Refer to EC-570, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionEBS0113P
HEATED OXYGEN SENSOR 1
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select “MANU TRIG” and adjust “TRIGGER POINT” to 100% in “DATA MONITOR” mode with CONSULT-
II.
3. Select “HO2S1 (B1)” and “HO2S1 MNTR (B1)”.
4. Hold engine speed at 2,000 rpm under no load during the follow-
ing steps.
5. Touch “RECORD” on CONSULT-II screen.
6. Check the following.
“HO2S1 MNTR (B1)” in “DATA MONITOR” mode changes
from “RICH” to “LEAN” to “RICH” more than 5 times in 10 sec-
onds.
5 times (cycles) are counted as shown at right.
“HO2S1 (B1)” voltage goes above 0.6V at least once.
“HO2S1 (B1)” voltage goes below 0.3V at least once.
“HO2S1 (B1)” voltage never exceeds 1.0V.Continuity should exist.
Continuity should not exist.
SEF646Y
SEF217YA
EC-890
[YD (WITH EURO-OBD)]
BASIC SERVICE PROCEDURE
BASIC SERVICE PROCEDUREPFP:00018
Fuel FilterEBS01172
DESCRIPTION
A water draining cock is on the lower side and a priming pump for bleeding air is on the upper side.
AIR BLEEDING
Pump the priming pump to bleed air.
When air is bled completely, the pumping of the priming pump
suddenly becomes heavy. Stop the operation at that time.
If it is difficult to bleed air by the pumping of the priming pump
(the pumping of the priming pump does not become heavy), dis-
connect the fuel supply hose between the fuel filter and the fuel
gallery. Then, perform the operation described above, and make
sure that fuel comes out. (Use a pan, etc. so as not to spill fuel.
Do not let fuel get on engine and other parts.) After that, connect
the hose, then bleed air again.
Start engine and let it idle for at least 1 minute after performing
air bleeding.
WATER DRAINING
1. Remove the fuel filter, filter bracket, protector assembly from the dash panel as follows.
a. Remove the air cleaner case (upper), air duct assembly, and vacuum hose for brake booster (between the
vacuum pump and vacuum pipe).
CAUTION:
After the duct is removed, cover the opening with gum tape, etc. to prevent foreign object from
getting into the engine during the operation.
b. Remove the mounting nuts on the dash panel, then remove the fuel filter, filter bracket, and protector
assembly from the dash panel.
It is not necessary to disconnect the fuel hose.
2. Using a tool such as a pliers, loosen the water draining cock at
the bottom of the fuel filter.
Loosening drain cock four to five turns causes water to
start draining.
Do not remove drain cock by loosening it excessively.
If water dose not drain properly, move the priming up and down.
CAUTION:
When the water is drained, the fuel is also drained. Use a
pan, etc. to avoid fuel adherence to the rubber parts such as
the engine mount insulator.
Do not over-tighten the water draining cock. This will dam-
age the cock thread, resulting in water or fuel leak.
3. Bleed air of the fuel filter. Refer to EC-890, "
AIR BLEEDING" .
4. Start the engine.
Fuel Pump Learning Value ClearingEBS01173
DESCRIPTION
In order to always keep optimum fuel pressure in fuel rail, the ECM controls fuel pump in high precision with
monitoring the signal of fuel rail pressure sensor.
Accordingly, the ECM always learns characteristic value of fuel pump. Fuel Pump Learning Value Clearing is
an operating to clear the value of the fuel pump learning.
It must be performed after the fuel pump is changed. When the ECM is replaced with brand new one, the Fuel
Pump Learning Value Clearing is not necessary to be performed. If the ECM to be replaced has the possibility
of learning the characteristic value of fuel pump, the Fuel Pump Learning Value Clearing is necessary to be
performed after the ECM has been replaced.
OPERATION PROCEDURE
NOTE:
Remove fuel pump without starting engine after performing Fuel Pump Learning Value Clearing.
PBIB1932E
SMA825B
TROUBLE DIAGNOSIS
EC-929
[YD (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
NOTE:
Any monitored item that does not match the vehicle being diagnosed is deleted from the display automatically.
ACTIVE TEST MODE
COOLING FAN
[LOW/HI/OFF]×
Indicates the control condition of the
cooling fans (determined by ECM
according to the input signal).
LOW ... Operates at low speed.
HI ... Operates at high speed.
OFF ... Stopped
EGR VOL CON/V [step]×
Indicates the EGR volume control value
computed by the ECM according to the
input signals.
The opening becomes larger as the
value increases.
INT/A VOLUME [mg/]
The intake air volume computed from the
mass air flow sensor signal is displayed.
BARO SEN [kPa]××
The barometric pressure (determined by
the signal voltage from the absolute
pressure sensor built into the ECM) is
displayed.
INT/M PRES SE [kPa]
Turbocharger boost (determined by the
signal voltage from the turbocharger
boost sensor) is displayed.
CYL COUNT [1/2/3/4]
The cylinder being injected is displayed.
1 ... Cylinder No.1 is injected.
2 ... Cylinder No.2 is injected.
3 ... Cylinder No.3 is injected.
4 ... Cylinder No.4 is injected.
Voltage [V]
Voltage, frequency, duty cycle or pulse
width measured by the probe.Only “#” is displayed if item is
unable to be measured.
Figures with “#”s are temporary
ones.
They are the same figures as an
actual piece of data which was
just previously measured. [Hz] or
[%] Frequency [msec], [Hz] or
[%]
DUTY-HI
DUTY-LOW
PLS WIDTH-HI
PLS WIDTH-LOWMONITOR ITEMECM
INPUT
SIGNALMAIN
SIG-
NALSCONDITION SPECIFICATION
TEST ITEM CONDITION JUDGEMENT CHECK ITEM (REMEDY)
POWER BAL-
ANCE
Engine: After warming up, idle the
engine.
A/C switch: OFF
Shift lever: N
Cut off each injector signal one at
a time using CONSULT-IIEngine runs rough or dies.
Harness and connectors
Compression
Fuel injector
COOLING FAN *
Ignition switch: ON
Operate the cooling fan at LOW,
HI speed and turn OFF using
CONSULT-II.Cooling fan moves at LOW, HI
speed and stops.
Harness and connector
Cooling fan motor
Cooling fan relay
ENG COOLANT
TEMP
Engine: Return to the original
trouble condition
Change the engine coolant tem-
perature using CONSULT-II.If trouble symptom disappears, see
CHECK ITEM.
Harness and connectors
Engine coolant temperature sen-
sor
Fuel injector
EC-930
[YD (WITH EURO-OBD)]
TROUBLE DIAGNOSIS
*:Leaving cooling fan OFF with CONSULT-II while engine is running may cause the engine to overheat.
REAL TIME DIAGNOSIS IN DATA MONITOR MODE
CONSULT-II has two kinds of triggers and they can be selected by touching “SETTING” in “DATA MONITOR”
mode.
1. “AUTO TRIG” (Automatic trigger):
–The malfunction will be identified on the CONSULT-II screen in
real time.
In other words, DTC/1st trip DTC/2nd trip DTC will be displayed
if the malfunction is detected by ECM.
At the moment a malfunction is detected by ECM, “MONITOR”
in “DATA MONITOR” screen is changed to “Recording Data ...
xx%” as shown in the figure, and the data after the malfunction
detection is recorded. Then when the percentage reached
100%, “REAL-TIME DIAG” screen is displayed. If “STOP” is
touched on the screen during “ Recording Data ... xx%”, “REAL-
TIME DIAG” screen is also displayed.
The recording time after the malfunction detection and the recording speed can be changed by “TRIG-
GER POINT” and “Recording Speed”. Refer to CONSULT-II OPERATION MANUAL.
2. “MANU TRIG” (Manual trigger):
–DTC/1st trip DTC/2nd trip DTC will not be displayed automati-
cally on CONSULT-II screen even though a malfunction is
detected by ECM.
DATA MONITOR can be performed continuously even though a
malfunction is detected.
Use these triggers as follows:
1. “AUTO TRIG”
–While trying to detect the DTC/1st trip DTC/2nd trip DTC by per-
forming the “DTC Confirmation Procedure”, be sure to select to
“DATA MONITOR (AUTO TRIG)” mode. You can confirm the
malfunction at the moment it is detected.
–While narrowing down the possible causes, CONSULT-II should be set in “DATA MONITOR (AUTO
TRIG)” mode, especially in case the incident is intermittent.
When you are inspecting the circuit by gently shaking (or twisting) the suspicious connectors, components
and harness in the DTC Confirmation Procedure, the moment a malfunction is found the DTC/1st trip
DTC/2nd trip DTC will be displayed. Refer to GI-23, "
How to Perform Efficient Diagnosis for an Electrical
Incident" , “INCIDENT SIMULATION TESTS”.
2. “MANU TRIG”
GLOW RLY
Ignition switch: ON (Engine
stopped)
Turn the glow relay ON and OFF
using CONSULT-II and listen to
operating sound.Glow relay makes the operating
sound.Harness and connector
Glow relay
EGR VOL CONT/
V
Ignition switch: ON
Change EGR volume control
valve opening step using CON-
SULT-II.EGR volume control valve makes
an operating sound.Harness and connector
EGR volume control valve
PRES REGULA-
TOR
Ignition switch: ON
Change fuel rail pressure using
CONSULT-IIFuel leaks.Fuel line
Fuel pressure relief valve
PUMP LEANT
CLEAR
This mode is used for performing Fuel Pump Learning Value Clearing. Refer to EC-890, "Fuel Pump Learning
Value Clearing" . TEST ITEM CONDITION JUDGEMENT CHECK ITEM (REMEDY)
PBIB0480E
SEF707X
DTC P0401 EGR FUNCTION
EC-1073
[YD (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
DTC P0401 EGR FUNCTIONPFP:14710
DescriptionEBS011OS
SYSTEM DESCRIPTION
*: These signals are sent to the ECM through CAN communication line.
This system controls flow rate of EGR led from exhaust manifold to intake manifold. The opening of the EGR
by-pass passage in the EGR volume control valve changes to control the flow rate. A built-in step motor
moves the valve in steps corresponding to the ECM output pulses. The opening of the valve varies for opti-
mum engine control. The optimum value stored in the ECM is determined by considering various engine con-
ditions.
The EGR volume control valve remains close under the following conditions.
Engine stopped
Engine starting
Low engine coolant temperature
High engine speed
Accelerator pedal fully depressed
COMPONENT DESCRIPTION
EGR Volume Control Valve
The EGR volume control valve uses a step motor to control the flow
rate of EGR from exhaust manifold. This motor has four winding
phases. It operates according to the output pulse signal of the ECM.
Two windings are turned ON and OFF in sequence. Each time an
ON pulse is issued, the valve opens or closes, changing the flow
rate. When no change in the flow rate is needed, the ECM does not
issue the pulse signal. A certain voltage signal is issued so that the
valve remains at that particular opening.
Sensor Input Signal to ECM ECM Function Actuator
Crankshaft position sensor Engine speed
EGR volume con-
trolEGR volume control
valve Vehicle speed sensor* Vehicle speed
Engine coolant temperature sensor Engine coolant temperature
Ignition switch Start signal
Accelerator pedal position sensor Accelerator pedal position
Mass air flow sensor Amount of intake air
Air conditioner switch
* Air conditioner operation
SEF908Y
SEF411Y
EC-1080
[YD (WITH EURO-OBD)]
DTC P0404 EGR VOLUME CONTROL VALVE
DTC P0404 EGR VOLUME CONTROL VALVEPFP:14710
DescriptionEBS011P6
SYSTEM DESCRIPTION
*: These signals are sent to the ECM through CAN communication line.
This system controls flow rate of EGR led from exhaust manifold to intake manifold. The opening of the EGR
by-pass passage in the EGR volume control valve changes to control the flow rate. A built-in step motor
moves the valve in steps corresponding to the ECM output pulses. The opening of the valve varies for opti-
mum engine control. The optimum value stored in the ECM is determined by considering various engine con-
ditions.
The EGR volume control valve remains close under the following conditions.
Engine stopped
Engine starting
Low engine coolant temperature
High engine speed
Accelerator pedal fully depressed
COMPONENT DESCRIPTION
EGR Volume Control Valve
The EGR volume control valve uses a step motor to control the flow
rate of EGR from exhaust manifold. This motor has four winding
phases. It operates according to the output pulse signal of the ECM.
Two windings are turned ON and OFF in sequence. Each time an
ON pulse is issued, the valve opens or closes, changing the flow
rate. When no change in the flow rate is needed, the ECM does not
issue the pulse signal. A certain voltage signal is issued so that the
valve remains at that particular opening.
Sensor Input Signal to ECM ECM Function Actuator
Crankshaft position sensor Engine speed
EGR volume con-
trolEGR volume control
valve Vehicle speed sensor* Vehicle speed
Engine coolant temperature sensor Engine coolant temperature
Ignition switch Start signal
Accelerator pedal position sensor Accelerator pedal position
Mass air flow sensor Amount of intake air
Air conditioner switch
* Air conditioner operation
SEF908Y
SEF411Y
BASIC SERVICE PROCEDURE
EC-1221
[YD (WITHOUT EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
BASIC SERVICE PROCEDUREPFP:00018
Fuel FilterEBS011X6
DESCRIPTION
A water draining cock is on the lower side and a priming pump for bleeding air is on the upper side.
AIR BLEEDING
Pump the priming pump to bleed air.
When air is bled completely, the pumping of the priming pump
suddenly becomes heavy. Stop the operation at that time.
If it is difficult to bleed air by the pumping of the priming pump
(the pumping of the priming pump does not become heavy), dis-
connect the fuel supply hose between the fuel filter and the fuel
gallery. Then, perform the operation described above, and make
sure that fuel comes out. (Use a pan, etc. so as not to spill fuel.
Do not let fuel get on engine and other parts.) After that, connect
the hose, then bleed air again.
Start engine and let it idle for at least 1 minute after performing
air bleeding.
WATER DRAINING
1. Remove the fuel filter, filter bracket, protector assembly from the dash panel as follows.
a. Remove the air cleaner case (upper), air duct assembly, and vacuum hose for brake booster (between the
vacuum pump and vacuum pipe).
CAUTION:
After the duct is removed, cover the opening with gum tape, etc. to prevent foreign object from
getting into the engine during the operation.
b. Remove the mounting nuts on the dash panel, then remove the fuel filter, filter bracket, and protector
assembly from the dash panel.
It is not necessary to disconnect the fuel hose.
2. Using a tool such as a pliers, loosen the water draining cock at
the bottom of the fuel filter.
Loosening drain cock four to five turns causes water to
start draining.
Do not remove drain cock by loosening it excessively.
If water dose not drain properly, move the priming up and down.
CAUTION:
When the water is drained, the fuel is also drained. Use a
pan, etc. to avoid fuel adherence to the rubber parts such as
the engine mount insulator.
Do not over-tighten the water draining cock. This will dam-
age the cock thread, resulting in water or fuel leak.
3. Bleed air of the fuel filter. Refer to EC-1221, "
AIR BLEEDING" .
4. Start the engine.
Fuel Pump Learning Value ClearingEBS011X7
DESCRIPTION
In order to always keep optimum fuel pressure in fuel rail, the ECM controls fuel pump in high precision with
monitoring the signal of fuel rail pressure sensor.
Accordingly, the ECM always learns characteristic value of fuel pump. Fuel Pump Learning Value Clearing is
an operating to clear the value of the fuel pump learning.
It must be performed after the fuel pump is changed. When the ECM is replaced with brand new one, the Fuel
Pump Learning Value Clearing is not necessary to be performed. If the ECM to be replaced has the possibility
of learning the characteristic value of fuel pump, the Fuel Pump Learning Value Clearing is necessary to be
performed after the ECM has been replaced.
OPERATION PROCEDURE
NOTE:
Remove fuel pump without starting engine after performing Fuel Pump Learning Value Clearing.
PBIB1932E
SMA825B
ON BOARD DIAGNOSTIC (OBD) SYSTEM
EC-1223
[YD (WITHOUT EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
ON BOARD DIAGNOSTIC (OBD) SYSTEMPFP:00028
DTC and MI Detection LogicEBS011X8
When a malfunction is detected, the malfunction (DTC) and freeze frame data are stored in the ECM memory.
The MI will light up each time the ECM detects malfunction. For diagnostic items causing the MI to light up,
refer to EC-1205, "
INDEX FOR DTC" .
Diagnostic Trouble Code (DTC)EBS011X9
HOW TO READ DTC
The DTC can be read by CONSULT-II only.
With CONSULT-II
CONSULT-II displays the DTC in "SELF-DIAG RESULTS" mode. Example: P0117, P0335, P1260, etc.
These numbers are prescribed by ISO15031-6.
(CONSULT-II also displays the malfunctioning component or system.)
HOW TO ERASE DTC
How to Erase DTC ( With CONSULT-II)
1. If the ignition switch stays ON after repair work, be sure to turn ignition switch OFF once. Wait at least 5
seconds and then turn it ON (engine stopped) again.
2. Touch “ENGINE”.
3. Touch “SELF-DIAG RESULTS”.
4. Touch “ERASE”. (The DTC in the ECM will be erased.)
The emission related diagnostic information in the ECM can be erased by selecting “ERASE” in the “SELF-
DIAG RESULTS” mode with CONSULT-II.
Freeze Frame DataEBS011XA
The ECM records the driving conditions such as calculated load value, engine coolant temperature, engine
speed, vehicle speed and intake manifold pressure at the moment a malfunction is detected.
The data, stored together with the DTC data, are called freeze frame data and displayed on CONSULT-II. For
details, see EC-1253
.
Only one set of freeze frame data can be stored in the ECM. If freeze frame data is stored in the ECM memory
and another freeze frame data occurs later, the first (original) freeze frame data remains unchanged in the
ECM memory.
Freeze frame data (along with the DTCs) are cleared when the ECM memory is erased. Procedures for clear-
ing the ECM memory are described in EC-1223, "
HOW TO ERASE DTC" .
PBIB2452E