HOW TO USE THIS MANUAL
GI-17
C
D
E
F
G
H
I
J
K
L
MB
GI
14 Wire color
This shows a code for the color of the wire.
B = Black
W = White
R = Red
G = Green
L = Blue
Y = Yellow
LG = Light GreenBR = Brown
OR or O = Orange
P = Pink
PU or V (Violet) = Purple
GY or GR = Gray
SB = Sky Blue
CH = Dark Brown
DG = Dark Green
When the wire color is striped, the base color is given first, followed by the stripe color as shown
below:
Example: L/W = Blue with White Stripe
15 Option description
This shows a description of the option abbreviation used on the page.
16 Switch
This shows that continuity exists between terminals 1 and 2 when the switch is in the A posi-
tion. Continuity exists between terminals 1 and 3 when the switch is in the B position.
17 Assembly parts
Connector terminal in component shows that it is a harness incorporated assembly.
18 Cell code
This identifies each page of the wiring diagram by section, system and wiring diagram page
number.
19 Current flow arrow
Arrow indicates electric current flow, especially where the direction of standard flow (vertically
downward or horizontally from left to right) is difficult to follow.
A double arrow “ ” shows that current can flow in either direction depending on cir-
cuit operation.
20 System branch
This shows that the system branches to another system identified by cell code (section and
system).
21 Page crossing
This arrow shows that the circuit continues to another page identified by cell code.
The C will match with the C on another page within the system other than the next or preced-
ing pages.
22 Shielded line
The line enclosed by broken line circle shows shield wire.
23Component box in
wave line
This shows that another part of the component is also shown on another page (indicated by
wave line) within the system.
24 Component name
This shows the name of a component.
25 Connector number
This shows the connector number.
The letter shows which harness the connector is located in.
Example: M : main harness. For detail and to locate the connector, refer to PG section "Main
Harness", “Harness Layout”. A coordinate grid is included for complex harnesses to aid in
locating connectors.
26 Ground (GND)
The line spliced and grounded under wire color shows that ground line is spliced at the
grounded connector.
27 Ground (GND)
This shows the ground connection. For detailed ground distribution information, refer to
"Ground Distribution" in PG section.
28 Connector views
This area shows the connector faces of the components in the wiring diagram on the page.
29 Common component
Connectors enclosed in broken line show that these connectors belong to the same compo-
nent.
30 Connector color
This shows a code for the color of the connector. For code meaning, refer to wire color codes,
Number 14 of this chart.
31Fusible link and fuse
box
This shows the arrangement of fusible link(s) and fuse(s), used for connector views of
"POWER SUPPLY ROUTING" in PG section.
The open square shows current flow in, and the shaded square shows current flow out.
32 Reference area
This shows that more information on the Super Multiple Junction (SMJ) and Joint Connectors
(J/C) exists on the PG section. Refer to "Reference Area" for details. Num-
berItem Description
POWER SUPPLY AND GROUND CIRCUIT
EC-127
[QR (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
6. CHECK ECM POWER SUPPLY CIRCUIT-II
1. Disconnect ECM relay.
2. Check voltage between ECM relay terminals 1 and 6 and
ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 8.
NG >> GO TO 7.
7. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E61, F38
20A fuse
Harness for open or short between ECM relay and battery
>> Repair open circuit or short to ground or short to power in harness or connectors.
8. CHECK OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Check harness continuity between ECM terminal 111 and ECM relay terminal 2.
Refer to Wiring Diagram.
2. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 10.
NG >> GO TO 9.
9. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors F41, M61
Harness for open or short between ECM relay and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
PBIB1973E
Voltage: Battery voltage
SEF420X
Continuity should exist.
POWER SUPPLY AND GROUND CIRCUIT
EC-129
[QR (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
13. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E60, F36
10A fuse
Harness for open or short between ECM relay and battery
>> Repair open circuit or short to ground or short to power in harness or connectors.
14. CHECK ECM POWER SUPPLY CIRCUIT-V
1. Disconnect ECM harness connector.
2. Check harness continuity between ECM terminals 119, 120 and ECM relay terminal 5.
Refer to Wiring Diagram.
3. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 16.
NG >> GO TO 15.
15. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors F41, M61
Harness for open or short between ECM relay and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
16. CHECK ECM RELAY
Refer to EC-131, "
Component Inspection" .
OK or NG
OK >> GO TO 17.
NG >> Replace ECM relay.Continuity should exist.
EC-142
[QR (WITH EURO-OBD)]
DTC P0031, P0032 HO2S1 HEATER
2. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E60, F36
Fuse block (J/B) connector E103
10A fuse
Harness for open or short between heated oxygen sensor 1 and fuse
>> Repair open circuit or short to ground or short to power in harness or connectors.
3. CHECK HO2S1 OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 24 and HO2S1 terminal 1.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 4.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
4. CHECK HEATED OXYGEN SENSOR 1 HEATER
Refer to EC-143, "
Component Inspection" .
OK or NG
OK >> GO TO 5.
NG >> Replace heated oxygen sensor 1.
5. CHECK INTERMITTENT INCIDENT
Refer to EC-123, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END Continuity should exist.
EC-298
[QR (WITH EURO-OBD)]
DTC P1122 ELECTRIC THROTTLE CONTROL FUNCTION
3. CHECK THROTTLE CONTROL MOTOR RELAY POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect throttle control motor relay.
3. Check voltage between throttle control motor relay terminals 2, 5
and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4. DETECT MALFUNCTIONING PART
Check the following.
15A fuse
Harness for open or short between throttle control motor relay and battery
>> Repair or replace harness or connectors.
5. CHECK THROTTLE CONTROL MOTOR RELAY INPUT SIGNAL CIRCUIT
1. Disconnect ECM harness connector.
2. Check harness continuity between throttle control motor relay terminal 3 and ECM terminal 3.
Refer to Wiring Diagram.
3. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 7.
NG >> GO TO 6.
6. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E61, F38
Harness for open or short between throttle control motor relay and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
PBIB1972E
Voltage: Battery voltage
PBIB0575E
Continuity should exist.
EC-424
[QR (WITH EURO-OBD)]
IGNITION SIGNAL
8. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E61, F38
20A fuse
Harness for open or short between ECM relay and battery
>> Repair or replace harness or connectors.
9. CHECK ECM RELAY
Refer to EC-426, "
Component Inspection" .
OK or NG
OK >> GO TO 17.
NG >> Replace ECM relay.
10. CHECK CONDENSER GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect condenser harness connector.
3. Check harness continuity between condenser terminal 2 and ground.
Refer to Wiring diagram.
4. Also check harness for short to power.
OK or NG
OK >> GO TO 11.
NG >> Repair open circuit or short to power in harness or connector.
11 . CHECK CONDENSER
Refer to EC-426, "
Component Inspection" .
OK or NG
OK >> GO TO 12.
NG >> Replace condenser.Continuity should exist.
EC-432
[QR (WITH EURO-OBD)]
INJECTOR CIRCUIT
3. CHECK INJECTOR POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect injector harness connector.
3. Turn ignition switch ON.
4. Check voltage between injector terminal 1 and ground with
CONSULT-II or tester.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors M61, F41
Harness connectors F1, F101
Fuse block (J/B) connector M1
10A fuse
Harness for open or short between injector and fuse
>> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK INJECTOR OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between injector terminal 2 and ECM terminals 22, 23, 41, 42.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 7.
NG >> GO TO 6.
PBIB1970E
Voltage: Battery voltage
PBIB0582E
Continuity should exist.
EC-448
[QR (WITH EURO-OBD)]
FUEL PUMP CIRCUIT
3. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors M17, B1
Fuse block (J/B) connector M1
15A fuse
Harness for open or short between fuel pump relay and fuse
>> Repair open circuit or short to ground or short to power in harness or connectors.
4. CHECK CONDENSER CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect condenser harness connector.
3. Check harness continuity between fuel pump relay terminal 3 and condenser terminal 1, condenser termi-
nal 2 and ground.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 6.
NG >> GO TO 5.
5. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors B22, B128 (RHD models)
Harness for open or short between fuel pump relay and condenser
Harness for open or short between condenser and ground
>> Repair open circuit or short to ground or short to power in harness connectors.
6. CHECK CONDENSER
Refer to EC-450, "
Component Inspection" .
OK or NG
OK >> GO TO 7.
NG >> Replace condenser.
7. CHECK FUEL PUMP POWER SUPPLY AND GROUND CIRCUIT FOR OPEN AND SHORT
1. Disconnect “fuel level sensor unit and fuel pump” harness con-
nector.
2. Check harness continuity between fuel pump relay terminal 3
and “fuel level sensor unit and fuel pump” terminal 5, “fuel level
sensor unit and fuel pump” terminal 3 and ground.
Refer to Wiring Diagram.
3. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 9.
NG >> GO TO 8.Continuity should exist.
Continuity should exist.PBIB0506E