B: STANDARD CHARGENJSC0017S04
SEL758W
*1: SC-4 *2: SC-7
Fig. 4 INITIAL CHARGING CURRENT SETTING (Standard charge)
CON-
VERTED
SPECIFIC
GRAVITYBATTERY TYPE
28B19R(L)
34B19R(L)
46B24R(L)
55B24R(L)
50D23R(L)
55D23R(L)
025 [YUASA type code]
027 [YUASA type code]
65D26R(L)
80D26R(L)
063 [YUASA type code]
067 [YUASA type code]
096 [YUASA type code]
75D31R(L)
95D31R(L)
115D31R(L)
110D26R(L)
95E41R(L)
065 [YUASA type code]
075 [YUASA type code]
096L [YUASA type code]
010S [YUASA type code]
130E41R(L)
1.100 -
1.1304.0 (A) 5.0 (A) 6.0 (A) 7.0 (A)8.0
(A)9.0 (A) 10.0 (A)13.0
(A)
1.130 -
1.1603.0 (A) 4.0 (A) 5.0 (A) 6.0 (A)7.0
(A)8.0 (A) 9.0 (A)11 . 0
(A)
1.160 -
1.1902.0 (A) 3.0 (A) 4.0 (A) 5.0 (A)6.0
(A)7.0 (A) 8.0 (A)9.0
(A)
1.190 -
1.2202.0 (A) 2.0 (A) 3.0 (A) 4.0 (A)5.0
(A)5.0 (A) 6.0 (A)7.0
(A)
Check battery type and determine the specified current using the table shown above.
After starting charging, adjustment of charging current is not necessary.
BATTERY
Battery Test and Charging Chart (Cont’d)
SC-10