2003 DODGE RAM engine oil

[x] Cancel search: engine oil

Page 2222 of 2895

DODGE RAM 2003  Service Repair Manual STANDARD PROCEDURE - FLUID AND FILTER
REPLACEMENT
For proper service intervals (Refer to LUBRICA-
TION & MAINTENANCE/MAINTENANCE SCHED-
ULES - DESCRIPTION). The service fluid fill after a
filter chang

Page 2223 of 2895

DODGE RAM 2003  Service Repair Manual is equal on both sides of the dipstick. If one side is
noticably higher than the other, the dipstick has
picked up some oil from the dipstick tube. Allow the
oil to drain down the dipstick tube and re

Page 2226 of 2895

DODGE RAM 2003  Service Repair Manual (11) Install reaction plate followed by waved snap-
ring.
(12) Check clutch pack clearance with feeler gauge
(Fig. 98). Clearance between waved spring and pres-
sure plate should 2.5-4.09 mm (0.098-0.

Page 2235 of 2895

DODGE RAM 2003  Service Repair Manual INSTALLATION
(1) Place replacement bearing in position in hous-
ing.
(2) Using a suitable driver, drive bearing into
housing until the snap-ring groove is visible.
(3) Install snap-ring to hold bearin

Page 2273 of 2895

DODGE RAM 2003  Service Repair Manual in an incorrect T.V. cable adjustment.Slide the
sheath of the T.V. cable (D) back and forth until the
centerlines of the T.V. cable end (B) and the throttle
bell crank lever (C) are aligned within one

Page 2274 of 2895

DODGE RAM 2003  Service Repair Manual IMPELLER
The impeller (Fig. 234) is an integral part of the
converter housing. The impeller consists of curved
blades placed radially along the inside of the housing
on the transmission side of the co

Page 2275 of 2895

DODGE RAM 2003  Service Repair Manual TURBINE
The turbine (Fig. 235) is the output, or driven,
member of the converter. The turbine is mounted
within the housing opposite the impeller, but is not
attached to the housing. The input shaft i

Page 2278 of 2895

DODGE RAM 2003  Service Repair Manual STATOR
Torque multiplication is achieved by locking the
stators over-running clutch to its shaft (Fig. 240).
Under stall conditions the turbine is stationary and
the oil leaving the turbine blades st