2002 DODGE RAM air bleeding

[x] Cancel search: air bleeding

Page 196 of 2255

DODGE RAM 2002  Service Repair Manual mile or two. However, if the lining is both soaked and
dirt contaminated, cleaning and/or replacement will
be necessary.
BRAKE LINING CONTAMINATION
Brake lining contamination is mostly a product of
le

Page 197 of 2255

DODGE RAM 2002  Service Repair Manual STANDARD PROCEDURE - PRESSURE
BLEEDING
Use Mopar brake fluid, or an equivalent quality
fluid meeting SAE J1703-F and DOT 3 standards
only. Use fresh, clean fluid from a sealed container at
all times.

Page 208 of 2255

DODGE RAM 2002  Service Repair Manual HYDRAULIC BOOSTER DIAGNOSIS CHART
CONDITION POSSIBLE CAUSES CORRECTION
Slow Brake Pedal Return 1. Excessive seal friction in booster. 1. Replace booster.
2. Faulty spool valve action. 2. Replace boost

Page 216 of 2255

DODGE RAM 2002  Service Repair Manual (4) Clamp hose shut between vacuum source and
check valve.
(5) Stop engine and observe vacuum gauge.
(6) If vacuum drops more than one inch HG (33
millibars) within 15 seconds, booster diaphragm or
ch

Page 225 of 2255

DODGE RAM 2002  Service Repair Manual OPERATION
Battery voltage is supplied to the CAB when a
speed of 15 miles per hour is reached. The CAB per-
forms a system initialization procedure at this point.
Initialization consists of a static a

Page 226 of 2255

DODGE RAM 2002  Service Repair Manual HCU pump and solenoids. A second base brake bleed-
ing procedure is then required to remove any air
remaining in the system.
(1) Perform the base brake bleeding, (Refer to 5 -
BRAKES/HYDRAULIC/MECHANI

Page 1301 of 2255

DODGE RAM 2002  Service Repair Manual FUEL DELIVERY - GASOLINE
DESCRIPTION - FUEL DELIVERY SYSTEM
The fuel delivery system consists of:
²the fuel pump module containing the electric
fuel pump, fuel filter/fuel pressure regulator, rollove

Page 1359 of 2255

DODGE RAM 2002  Service Repair Manual (5) Vacuum leak ? Check condition of banjo fit-
tings, banjo bolts, and sealing washers. If leaks are
not present, a leak exists within VP-44 pump.
Replacement of VP-44 requires authorization.DIAGNOSI
Page:   1-8 9-16 17-24 next >