SUZUKI GRAND VITARA 2001 2.G Owners Manual 0B-6 MAINTENANCE AND LUBRICATION
POWER STEERING PUMP AND/OR A/C COMPRESSOR 
DRIVE BELTS (IF EQUIPPED) INSPECTION 
1) Disconnect negative (–) cable at battery.
2) Inspect belt for cracks, cuts, defor

Page 26 of 656

SUZUKI GRAND VITARA 2001 2.G Owners Manual AIR CONDITIONING (OPTIONAL) 1B-1
1B
SECTION 1B
AIR CONDITIONING (OPTIONAL)
CONTENTS
General Description ....................................... 1B-3
Refrigerant Type ..................................

Page 37 of 656

SUZUKI GRAND VITARA 2001 2.G Owners Manual 1B-12 AIR CONDITIONING (OPTIONAL)
Performance diagnosis table
HIGH PRESSURE GAUGE
LOW PRESSURE GAUGE
THERMOMETER AT CENTER DUCT
Condition Possible Cause Correction
Pressure high 
(“A” area of high

Page 38 of 656

SUZUKI GRAND VITARA 2001 2.G Owners Manual AIR CONDITIONING (OPTIONAL) 1B-13
Detail diagnosis table (at ambient temperature within 30 - 35 °C (85 - 95 °F))
Condition Possible Cause Correction
MANIFOLD 
GAUGEMPa 
(kg/cm
2) 
(psi)Detail
Lo Hi

Page 50 of 656

SUZUKI GRAND VITARA 2001 2.G Owners Manual AIR CONDITIONING (OPTIONAL) 1B-25
On-Vehicle Service
Precaution
When servicing air conditioning system, the following rules must be observed.
Piping
When connecting hoses and pipes, apply a few drops

Page 63 of 656

SUZUKI GRAND VITARA 2001 2.G Owners Manual 1B-38 AIR CONDITIONING (OPTIONAL)
Compressor Assembly
INSPECTION
1) Install manifold gauge set (1) as shown in the figure.
2) Close Hi (4) and Lo (5) side valves.
3) Run engine at fast idle.
4) Check

Page 74 of 656

SUZUKI GRAND VITARA 2001 2.G Owners Manual POWER STEERING (P/S) SYSTEM 3B1-3
Hydraulic Pressure in P/S Circuit
Hydraulic pressure check
1) After cleaning joint of high pressure hose and P/S pump
thoroughly, disconnect hose from pump and instal

Page 75 of 656

SUZUKI GRAND VITARA 2001 2.G Owners Manual 3B1-4 POWER STEERING (P/S) SYSTEM
5) Check relief pressure.
a) Increase engine speed to about 1500 r/min (rpm). Close
gauge valve gradually while watching pressure increase
indicated by gauge and take