1B-2 AIR CONDITIONING (OPTIONAL)
Charging .................................................... 1B-22
On-Vehicle Service ...................................... 1B-25
Precaution .................................................. 1B-25
Piping ..................................................... 1B-25
Handling refrigerant HFC-134a (R-134a) 1B-26
Refrigerant recovery............................... 1B-26
Refrigerant charge ................................. 1B-26
Replenishing compressor oil .................. 1B-27
Rear A/C Unit (Rear A/C Evaporator) ........ 1B-28
Rear Expansion Valve ............................... 1B-29
Rear A/C Evaporator Temperature
Controller ................................................... 1B-30
Refrigerant Pipes and Hoses ..................... 1B-31
Solenoid Valve ........................................... 1B-32
Rear Blower Motor Assembly .................... 1B-33Rear Blower Motor Relay and Solenoid
Valve Relay................................................ 1B-34
Rear A/C Main Switch................................ 1B-34
Rear Blower Motor Resistor....................... 1B-35
Rear Blower Motor Switch ......................... 1B-36
Rear A/C No.1 and No.2 Duct ................... 1B-37
Rear A/C No.1 duct ................................ 1B-37
Rear A/C No.2 duct ................................ 1B-37
Compressor Assembly............................... 1B-38
Magnet Clutch............................................ 1B-41
Required Service Materials ......................... 1B-44
Tightening Torque Specification................ 1B-44
Special Tools ............................................... 1B-44

AIR CONDITIONING (OPTIONAL) 1B-3
General Description
Refrigerant Type
Whether the A/C in the vehicle being serviced uses HFC-134a
(R-134a) or CFC-12 (R-12) is indicated on LABEL on the com-
pressor. Also, it can be checked by the shape of the service
(charge) valve.
Refrigerant Flow of Air Conditioning System
[A] : HFC-134a (R-134a)
[B] : CFC-12 (R-12)
1. Compressor label
2. Service valve
NOTE:
For single A/C model, refer to the same section of the Service Manual mentioned in FOREWORD of
this manual.
[A] : Dual A/C model 3. Condenser assembly 6. Expansion valve 9. Rear expansion valve
1. Compressor 4. Receiver/dryer 7. A/C evaporator 10. Rear A/C evaporator
2. Magnet clutch 5. Dual pressure switch 8. Solenoid valve
[A]10
8
9
5
7
6
3
2
14 : Liquid
: Vapor
: Superheated Vapor
![SUZUKI GRAND VITARA 2001 2.G Owners Manual 1B-4 AIR CONDITIONING (OPTIONAL)
Major Components And Location
[A] : Dual A/C model 6. Receiver/dryer 13. Suction pipe 20. Ventilation air
[B] : Single A/C model 7. Front expansion valve 14. Discharge SUZUKI GRAND VITARA 2001 2.G Owners Manual 1B-4 AIR CONDITIONING (OPTIONAL)
Major Components And Location
[A] : Dual A/C model 6. Receiver/dryer 13. Suction pipe 20. Ventilation air
[B] : Single A/C model 7. Front expansion valve 14. Discharge](/manual-img/20/7584/w960_7584-28.png)
1B-4 AIR CONDITIONING (OPTIONAL)
Major Components And Location
[A] : Dual A/C model 6. Receiver/dryer 13. Suction pipe 20. Ventilation air
[B] : Single A/C model 7. Front expansion valve 14. Discharge pipe 21. Rear A/C air
1. Front cooling unit 8. Heater unit 15. Recirculation air 22. Room air
2. Front A/C evaporator 9. Rear A/C unit 16. Fresh air 23. Solenoid valve
3. Front blower fan motor 10. Rear blower fan motor 17. Defroster air 24. Rear A/C evaporator
4. Compressor 11. Rear expansion valve 18. Demister air
5. Condenser assembly 12. Liquid pipe 19. Foot air
17 17
18 18
16 [A]
[B]15
21
2211
23
9
24
10 141320
21
19 19
4 12
6 312
78
17 17
18 18
16
15
20
19 19 1
2
8 5
7
12
6
513
4 14

1B-6 AIR CONDITIONING (OPTIONAL)
Diagnosis
General
Main A/C system (front A/C system)
Condition Possible Cause Correction
Cool air does not
come out (A/C system
does not operative)No refrigerant Perform recover, evacuation and
charging.
Fuse blown Check “IG METER”, “REAR DEFG”
and “A/C” fuses, and check for
short circuit to ground.
A/C switch faulty Check A/C switch.
Blower motor switch faulty Check blower motor switch.
A/C evaporator temperature sensor (A/C evap-
orator thermistor) faultyCheck A/C evaporator tempera-
ture sensor (A/C evaporator ther-
mistor).
Refrigerant (dual) pressure switch faulty Check refrigerant (dual) pressure
switch.
Wiring or grounding faulty Repair as necessary.
A/C ON permission signal in ECM faulty Check A/C ON permission signal.
A/C controller and its circuit faulty Check A/C controller and its circuit.
Cool air does not
come out (A/C com-
pressor does not
operative (won’t rota-
tive))Magnet clutch faulty Check magnet clutch.
Compressor relay faulty Check compressor thermal switch.
Compressor relay faulty Check compressor relay.
Drive belt loose or broken Adjust or replace drive belt.
Compressor faulty Check compressor.
A/C ON permission signal in ECM faulty Check A/C ON permission signal.
A/C controller faulty Check A/C controller.
Cool air does not
come out (A/C con-
denser cooling fan
motor does not opera-
tive)Condenser cooling fan motor relay faulty Check condenser cooling fan motor
relay.
Wiring or grounding faulty Repair as necessary.
A/C condenser fan motor relay signal in ECM
faultyCheck A/C condenser cooling fan
motor relay signal.
Condenser cooling fan motor faulty Check condenser cooling fan
motor.
Cool air does not
come out (Blower
motor does not opera-
tive)Fuse blown Check “FRONT BLOW” and
“REAR DEFG” fuses, and check for
short circuit to ground.
Blower motor relay faulty Check blower motor relay.
Blower motor resistor faulty Check blower motor resistor.
Blower motor switch faulty Check blower motor switch.
Wiring or grounding faulty Repair as necessary.
Blower motor faulty Check blower motor.

AIR CONDITIONING (OPTIONAL) 1B-7
Cool air does not
come out or insuffi-
cient cooling (A/C sys-
tem normal operative)Insufficient or excessive charge of refrigerant Check charge of refrigerant.
Refrigerant leak in system Check system for leaks.
Condenser clogged Check condenser.
A/C evaporator clogged or frosted Check A/C evaporator.
A/C evaporator temperature sensor (A/C evap-
orator thermistor) faultyCheck A/C evaporator tempera-
ture sensor (A/C evaporator ther-
mistor).
A/C controller faulty Check A/C controller.
Expansion valve faulty Check expansion valve.
Drive belt slipping Check or replace drive belt.
Magnetic clutch faulty Check magnetic clutch.
Cool air does not
come out or insuffi-
cient cooling (A/C sys-
tem normal operative)Compressor faulty Check compressor.
Air in A/C system Replace condenser dryer, and then
perform evacuation and charging.
Air leaking from cooling unit or air duct Repair as necessary.
Heater and ventilation system faulty Check air inlet box assembly.
Check heater control lever assem-
bly.
Check heater assembly.
Blower motor faulty Check blower motor.
Excessive compressor oil existing in A/C sys-
temPull out compressor oil in A/C sys-
tem circuit, and replace compres-
sor.
Cool air does not
comes out only inter-
mittentlyWiring connection faulty Repair as necessary.
Expansion valve faulty Check expansion valve.
Excessive moisture in A/C system Replace condenser dryer, and then
perform evacuation and charging.
A/C controller faulty Check A/C controller.
Magnetic clutch faulty Check magnetic clutch.
Excessive charge of refrigerant Check charge of refrigerant.
Cool air comes out
only at high speedsCondenser clogged Check condenser.
Insufficient charge of refrigerant Check charge of refrigerant.
Air in A/C system Replace condenser dryer, and then
perform evacuation and charging.
Drive belt slipping Adjust or replace drive belt.
Compressor faulty Check compressor.
Cool air does not
comes out only at high
speedsExcessive charge of refrigerant Check charge refrigerant.
A/C evaporator frosted Check A/C evaporator.
Check A/C thermistor.
Insufficient velocity of
cooled airA/C evaporator clogged or frosted Check A/C evaporator.
Air leaking from cooling unit or air duct Repair as necessary.
Blower motor faulty Check blower motor.
Wiring or grounding faulty Repair as necessary. Condition Possible Cause Correction

1B-8 AIR CONDITIONING (OPTIONAL)
Rear A/C system
Condition Possible Cause Correction
Cool air dose not come
out (Rear blower motor
normal operative)Solenoid valve relay faulty Check solenoid valve relay, and then
replace if necessary
Solenoid valve faulty Check solenoid valve, and then replace if
necessary
Diode in rear A/C harness faulty Check diode, and then replace rear A/C
harness if necessary
Rear A/C evaporator temperature controller faulty Check rear A/C evaporator temperature
controller, and then replace if necessary
Rear blower motor switch faulty Check rear blower motor switch, and
then repair rear A/C evaporator and
check rear A/C evaporator temperature
controller if necessary
Rear A/C evaporator clogged or frosted Check rear A/C evaporator, and then
replace if necessary
Rear expansion valve faulty Check rear expansion valve, and then
replace if necessary
Air leaking from rear A/C unit or air duct Check and repair if necessary
Insufficient or excessive charge of refrigerant Check charge of refrigerant, and then
perform recovery, evacuation and charg-
ing if necessary
Refrigerant pipe or hose deformed Check pipe (hose), and then replace if
necessary
Cool air dose not come
out (Rear blower motor
dose not operative)Fuse blown Check “A/C” and “REAR BLOW” fuses,
and then check for short circuit to ground
Rear blower motor relay faulty Check rear blower motor relay, and then
replace if necessary
Rear A/C main switch faulty Check rear A/C main switch, and then
replace if necessary
Rear blower motor switch faulty Check rear blower motor switch, and
then replace if necessary
Rear blower motor resister faulty Check rear blower motor resister, and
then replace if necessary
Wiring or grounding faulty Check and repair
Rear blower motor faulty Check rear blower motor, and then
replace if necessary
Cool air dose not come
out at only intermittentlyLoose or poor connected wiring connector Connect connector correctly
Rear expansion valve faulty Check rear expansion valve, and then
replace if necessary
Rear A/C evaporator temperature controller faulty Check rear A/C evaporator temperature
controller, and then replace if necessary
Wiring or grounding faulty Check and repair
Cool air dose not come
out at only high speedRear A/C evaporator frosted Check rear A/C evaporator temperature,
evaporator drain hose and then replace if
necessary
Insufficient velocity of
cooled airRear A/C evaporator clogged or frosted Check rear A/C evaporator, and then
repair rear A/C evaporator or check rear
A/C evaporator temperature if necessary
Air leaking from rear A/C unit or air duct Check rear A/C unit and air duct, and
then repair if necessary
Rear blower motor faulty Check rear blower motor, and then
replace if necessary
Wiring or grounding faulty Check and repair

1B-10 AIR CONDITIONING (OPTIONAL)
Performance Diagnosis
1) Confirm that vehicle and environmental conditions are as fol-
lows.
Vehicle is not exposed to direct sun.
Ambient temperature is within 15 - 35 °C (59 - 95 °F).
2) Make sure that high pressure valve (1) and low pressure
valve (2) of manifold gauge (3) are firmly closed.
3) Connect high pressure charging hose (4) to high pressure
service valve (5) on vehicle, and connect low pressure
charging hose (6) to low pressure service valve (7) on vehi-
cle.
4) Bleed the air in charging hoses (3), (4) by loosening their
respective nuts on manifold gauge, utilizing the refrigerant
pressure. When a hiss is heard, immediately tighten nut.
5) Warm up engine to normal operating temperature (engine
coolant temperature at 80 - 90 °C (176 - 194 °F)) and keep it
at specified idle speed.
6) Operate A/C at the following conditions.
Main (front) A/C switch at ON position.
Rear A/C main switch at ON position (if equipped).
Front blower motor switch at max position.
Rear blower motor switch at max position (if equipped).
Air outlet control button at face position.
Temperature control lever at max cool position.
Vehicle door at all open.
Air inlet door at recirculation position.
7) Keep all windows, doors and engine food open.
8) With about 20 mm (0.8 in.) of dry bulb thermometer (1)
inserted into center face air outlet (2), rear A/C air outlet (3)
(dual A/C model only) and near A/C evaporator air inlet, read
temperature indicated on each thermometer. CAUTION:
Do not interchange high and low pressure charging
hoses by mistake.
2
64
3
75 1
3
1
2

AIR CONDITIONING (OPTIONAL) 1B-11
9) Check for each pressure of low side and high side if it is
within shaded range of graph.
If each gauge reading is out of specified pressure, correct
defective part referring to “PERFORMANCE DIAGNOSIS
TABLE”.
Example :
10) Check inlet port temperature-to-outlet port temperature rela-
tionship using graph.
For example, if A/C evaporator inlet port temperature is 25
°C (77 °F) and center face air outlet temperature is 8 °C
(46.4 °F), their crossing point is within acceptable range as
shown in graph.
11) If crossing point is out of acceptable range, diagnose trouble
referring to “PERFORMANCE DIAGNOSIS TABLE”.
12) Check that difference in temperature of center face air outlet
air and rear A/C air outlet air are within 5 °C (41 °F).
If the rear A/C air outlet air temperature is higher over 5 °C
(41 °F) than center face air outlet air temperature, check rear
A/C unit. Gauges should read as follows
when ambient temperature is 30 °C (86 °F)
Pressure on high pressure
gauge (HI) :1400 - 1750 kPa
14.0 - 17.5 kg/cm
2
199.1 - 248.9 psi
Pressure on high pressure
gauge (LO) :230 - 350 kPa
2.3 - 3.5 kg/cm
2
32.7 - 49.8 psi
NOTE:
Pressure registered on gauge varies with ambient tem-
perature. Therefore, use the graphs when determining if
pressures are normal or not.