2001 INFINITI QX4 Idle air

[x] Cancel search: Idle air

Page 659 of 2395

INFINITI QX4 2001  Factory Service Manual MONITOR ITEM CONDITION SPECIFICATION
VENT CONT/VIIgnition switch: ON OFF
HO2S1 HTR (B1)
HO2S1 HTR (B2)IEngine speed: Below 3,600 rpm ON
IEngine speed: Above 3,600 rpm OFF
HO2S2 HTR (B1)
HO2S2 HTR (B2)

Page 665 of 2395

INFINITI QX4 2001  Factory Service Manual TERMI-
NAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
25 W/G Tachometer[Engine is running]
IWarm-up condition
IIdle speed7-8VH
SEF579X
[Engine is running]
IWarm-up condition
IEngine speed is 2,500

Page 666 of 2395

INFINITI QX4 2001  Factory Service Manual TERMI-
NAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
42 B/Y Start signal[Ignition switch ªONº]Approximately 0V
[Ignition switch ªSTARTº]9 - 12V
43 R Ignition switch[Ignition switch ªOFFº]0V

Page 667 of 2395

INFINITI QX4 2001  Factory Service Manual TERMI-
NAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
61 OR Mass air flow sensor[Engine is running]
IWarm-up condition
IIdle speed1.2 - 1.8V
[Engine is running]
IWarm-up condition
IEngine speed is

Page 668 of 2395

INFINITI QX4 2001  Factory Service Manual TERMI-
NAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
71 OR/LHeated oxygen sensor
2 (rear) (bank 2)[Engine is running]
IWarm-up condition
IEngine speed is 2,000 rpm.0 - Approximately 1.0V
72 ORHeat

Page 671 of 2395

INFINITI QX4 2001  Factory Service Manual DescriptionNBEC0717The specification (SP) value indicates the tolerance of the value that is displayed in ªDATA MONITOR (SPEC)º
mode of CONSULT-II during normal operation of the Engine Control Syste

Page 685 of 2395

INFINITI QX4 2001  Factory Service Manual SEF958Y
Component DescriptionNBEC0050The mass air flow sensor is placed in the stream of intake air. It
measures the intake flow rate by measuring a part of the entire
intake flow. It consists of a ho

Page 687 of 2395

INFINITI QX4 2001  Factory Service Manual SEF058Y
PROCEDURE FOR MALFUNCTION ANBEC0054S01With CONSULT-IINBEC0054S01011) Turn ignition switch ªONº.
2) Select ªDATA MONITORº mode with CONSULT-II.
3) Wait at least 6 seconds.
4) If 1st trip DT