7 CHECK HO2S1 (FRONT) INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Disconnect ECM harness connector.
2. Check harness continuity between ECM terminal and front HO2S terminal as follows.
Refer to Wiring Diagram.
MTBL0473
Continuity should exist.
3. Check harness continuity between ECM terminal or FRONT HO2S terminal and ground as follows.
Refer to Wiring Diagram.
MTBL0474
Continuity should not exist.
4. Also check harness for short to power.
OK or NG
OK©GO TO 8.
NG©Repair open circuit or short to ground or short to power in harness or connectors.
8 CHECK HEATED OXYGEN SENSOR 1 HEATER (FRONT)
Check resistance between HO2S1 (front) terminals as follows.
SEF969Y
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a
hard surface such as a concrete floor; use a new one.
OK or NG
OK©GO TO 9.
NG©GO TO 13.
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0133, P0153 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(RESPONSE MONITORING)
Diagnostic Procedure (Cont'd)
EC-227
Page 775 of 2395

DescriptionNBEC0123SYSTEM DESCRIPTIONNBEC0123S01
Sensor Input Signal to ECMECM func-
tionActuator
Crankshaft position sensor (POS)
Engine speedHeated
oxygen
sensor 1
heater
(front) con-
trolHeated oxygen sensor 1 heat-
ers (front)
Crankshaft position sensor (REF)
The ECM performs ON/OFF control of the heated oxygen sensor 1 heaters (front) corresponding to the engine
speed.
OPERATIONNBEC0123S02
Engine speed rpm Heated oxygen sensor 1 heaters (front)
Above 3,600 OFF
Below 3,600 ON
CONSULT-II Reference Value in Data Monitor
Mode
NBEC0124Specification data are reference values.
MONITOR ITEM CONDITION SPECIFICATION
HO2S1 HTR (B1)
HO2S1 HTR (B2)IEngine speed: Below 3,600 rpm ON
IEngine speed: Above 3,600 rpm OFF
ECM Terminals and Reference ValueNBEC0657Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
TERMI-
NAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
3 L/ORHeated oxygen sensor
1 heater (front) (bank
1)[Engine is running]
IEngine speed is below 3,600 rpm.0 - 1.0V
[Engine is running]
IEngine speed is above 3,600 rpm.BATTERY VOLTAGE
(11 - 14V)
2 R/GHeated oxygen sensor
1 heater (front) (bank
2)[Engine is running]
IEngine speed is below 3,600 rpm.0 - 1.0V
[Engine is running]
IEngine speed is above 3,600 rpm.BATTERY VOLTAGE
(11 - 14V)
DTC P0135, P0155 HEATED OXYGEN SENSOR 1 HEATER (FRONT) (BANK
1)/(BANK 2)
Description
EC-240
Page 776 of 2395

On Board Diagnosis LogicNBEC0126Malfunction is detected when the current amperage in the heated
oxygen sensor 1 heater (front) circuit is out of the normal range.
[An improper voltage drop signal is sent to ECM through the heated
oxygen sensor 1 heater (front).]
Possible CauseNBEC0437IHarness or connectors
(The heated oxygen sensor 1 heater (front) circuit is open or
shorted.)
IHeated oxygen sensor 1 heater (front)
SEF058Y
DTC Confirmation ProcedureNBEC0127NOTE:
If ªDTC Confirmation Procedureº has been previously conducted,
always turn ignition switch ªOFFº and wait at least 10 seconds
before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that bat-
tery voltage is between 10.5V and 16V at idle.
WITH CONSULT-IINBEC0127S011) Turn ignition switch ªONº and select ªDATA MONITORº mode
with CONSULT.
2) Start engine and run it for at least 6 seconds at idle speed.
3) If 1st trip DTC is detected, go to ªDiagnostic Procedureº,
EC-244.
WITH GSTNBEC0127S021) Start engine and run it for at least 6 seconds at idle speed.
2) Turn ignition switch ªOFFº and wait at least 10 seconds.
3) Start engine and run it for at least 6 seconds at idle speed.
4) Select ªMODE 3º with GST.
5) If DTC is detected, go to ªDiagnostic Procedureº, EC-244.
IWhen using GST, ªDTC Confirmation Procedureº should
be performed twice as much as when using CONSULT-II
because GST cannot display MODE 7 (1st trip DTC) con-
cerning this diagnosis. Therefore, using CONSULT-II is
recommended.
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0135, P0155 HEATED OXYGEN SENSOR 1 HEATER (FRONT) (BANK
1)/(BANK 2)
On Board Diagnosis Logic
EC-241
Page 777 of 2395
Wiring DiagramNBEC0128RIGHT BANKNBEC0128S01
MEC949C
DTC P0135, P0155 HEATED OXYGEN SENSOR 1 HEATER (FRONT) (BANK
1)/(BANK 2)
Wiring Diagram
EC-242
Page 778 of 2395
LEFT BANKNBEC0128S02
MEC950C
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0135, P0155 HEATED OXYGEN SENSOR 1 HEATER (FRONT) (BANK
1)/(BANK 2)
Wiring Diagram (Cont'd)
EC-243
Page 779 of 2395
Diagnostic ProcedureNBEC0129
1 CHECK HO2S1 (FRONT) POWER SUPPLY CIRCUIT
1. Turn ignition switch ªOFFº.
2. Check heated oxygen sensor 1 (front) harness protector color.
SEF505Y
3. Disconnect corresponding heated oxygen sensor 1 (front) harness connector.
SEF965Y
SEF966Y
4. Turn ignition switch ªONº.
5. Check voltage between HO2S1 (front) terminal 1 and ground with CONSULT-II or tester.
SEF970Y
OK or NG
OK©GO TO 3.
NG©GO TO 2.
DTC P0135, P0155 HEATED OXYGEN SENSOR 1 HEATER (FRONT) (BANK
1)/(BANK 2)
Diagnostic Procedure
EC-244
Page 780 of 2395

2 DETECT MALFUNCTIONING PART
Check the following.
IHarness connectors M32, F23
IFuse block (J/B) connector M10
I15A fuse
IHarness for open or short between heated oxygen sensor 1 (front) and fuse
©Repair harness or connectors.
3 CHECK HO2S1 (FRONT) OUTPUT CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch ªOFFº.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal and HO2S1 terminal as follows.
Refer to Wiring Diagram.
MTBL0520
Continuity should exist.
4. Also check harness for short to ground and short to power.
OK or NG
OK©GO TO 4.
NG©Repair open circuit or short to ground or short to power in harness or connectors.
4 CHECK HEATED OXYGEN SENSOR 1 HEATER (FRONT)
Check resistance between HO2S1 (front) terminals as follows.
SEF969Y
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a
hard surface such as a concrete floor; use a new one.
OK or NG
OK©GO TO 6.
NG©GO TO 5.
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0135, P0155 HEATED OXYGEN SENSOR 1 HEATER (FRONT) (BANK
1)/(BANK 2)
Diagnostic Procedure (Cont'd)
EC-245
Page 781 of 2395
5 REPLACE HEATED OXYGEN SENSOR 1 (FRONT)
1. Turn ignition switch ªOFFº.
2. Check heated oxygen sensor 1 (front) harness protector color.
SEF505Y
CAUTION:
Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner tool
J-43897-18 or J-43897-12 and approved anti-seize lubricant.
©Replace malfunctioning heated oxygen sensor 1 (front).
6 CHECK INTERMITTENT INCIDENT
Refer to ªTROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENTº, EC-140.
©INSPECTION END
DTC P0135, P0155 HEATED OXYGEN SENSOR 1 HEATER (FRONT) (BANK
1)/(BANK 2)
Diagnostic Procedure (Cont'd)
EC-246