2001 INFINITI QX4 Engine control

[x] Cancel search: Engine control

Page 918 of 2395

INFINITI QX4 2001  Factory Service Manual SEF194Y
SEF340X
WITH CONSULT-IINBEC0239S011) Start engine and warm it up to normal operating temperature.
2) Turn ignition switch ªOFFº and wait at least 10 seconds.
3) Turn ignition switch ªONº.

Page 920 of 2395

INFINITI QX4 2001  Factory Service Manual Diagnostic ProcedureNBEC0241
1 CHECK RUBBER TUBE
1. Turn ignition switch ªOFFº.
2. Check rubber tube connected to the EVAP control system pressure sensor for clogging, vent, kink, disconnection or
i

Page 921 of 2395

INFINITI QX4 2001  Factory Service Manual 4 CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
1. Turn ignition switch ªONº.
2. Check voltage between EVAP control system pressure sensor terminal 3 and ground with CONSULT-II or t

Page 922 of 2395

INFINITI QX4 2001  Factory Service Manual 8 CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND
SHORT
1. Disconnect ECM harness connector.
2. Check harness continuity between ECM terminal 84 and EVAP control system pre

Page 931 of 2395

INFINITI QX4 2001  Factory Service Manual SEF565X
DTC Confirmation ProcedureNBEC0646
SEF566X
SEF874X
SEF567X
CAUTION:
Never remove fuel filler cap during the DTC Confirmation Pro-
cedure.
NOTE:
IIf DTC P0455 is displayed with P1448, perform t

Page 937 of 2395

INFINITI QX4 2001  Factory Service Manual 11 CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
With CONSULT-II
1. Disconnect vacuum hose to EVAP canister purge volume control solenoid valve at EVAP service port.
2. Start engin

Page 938 of 2395

INFINITI QX4 2001  Factory Service Manual 14 CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT-II
1. Start engine.
2. Perform ªPURG VOL CONT/Vº in ªACTIVE TESTº mode with CONSULT-II. Check that engine speed varies accor

Page 940 of 2395

INFINITI QX4 2001  Factory Service Manual 16 CHECK ABSOLUTE PRESSURE SENSOR
1. Remove absolute pressure sensor with its harness connector connected.
SEF961Y
2. Remove hose from absolute pressure sensor.
3. Install a vacuum pump to absolute pr