Page 39 of 87

L
6-1
PERIODIC MAINTENANCE AND MINOR REPAIR
/Net/layout8/layout_G2/work/Imai_work/OM-PS/AA9149_XV535-E6/English/E-6.frame
EAU00464
Periodic inspection, adjustment and lu-
brication will keep your motorcycle in
the safest and most efficient condition
possible. Safety is an obligation of the
motorcycle owner. The maintenance
and lubrication schedule chart should
be considered strictly as a guide to
general maintenance and lubrication
intervals. YOU MUST TAKE INTO
CONSIDERATION THAT WEATHER,
TERRAIN, GEOGRAPHICAL LOCA-
TIONS, AND A VARIETY OF INDIVID-
UAL USES ALL TEND TO DEMAND
THAT EACH OWNER ALTER THIS
TIME SCHEDULE TO SHORTER IN-
TERVALS TO MATCH THE ENVI-
RONMENT. The most important points
of motorcycle inspection, adjustment,
and lubrication are explained in the fol-
lowing pages.
EW000060
If you are not familiar with motor-
cycle service, this work should be
done by a Yamaha dealer.
EAU00462
1. Tool kit
EAU00469
Tool kit
The service information included in this
manual is intended to provide you, the
owner, with the necessary information
for completing some of your own pre-
ventive maintenance and minor re-
pairs. The tools provided in the ownerÕs
tool kit are to assist you in the perfor-
mance of periodic maintenance. How-
ever, some other tools such as a torque
wrench are also necessary to perform
the maintenance correctly.
NOTE:
If you do not have necessary tools re-
quired during a service operation, take
your motorcycle to a Yamaha dealer
for service.
EW000063
Modifications to this motorcycle not
approved by Yamaha may cause
loss of performance, and render it
unsafe for use. Consult a Yamaha
dealer before attempting any chang-
es.
Page 44 of 87
R
6-6
PERIODIC MAINTENANCE AND MINOR REPAIR
/Net/layout8/layout_G2/work/Imai_work/OM-PS/AA9149_XV535-E6/English/E-6.frame
a. Spark plug gap
Installation
1. Measure the electrode gap with a
wire thickness gauge and, if nec-
essary, adjust the gap to specifica-
tion.
2. Clean the gasket surface. Wipe off
any grime from the threads.
3. Install the spark plug and tighten it
to the specified torque. Spark plug gap:
0.7 ~ 0.8 mm
NOTE:
If a torque wrench is not available when
you are installing a spark plug, a good
estimate of the correct torque is 1/4 to
1/2 turn past finger tight. Have the
spark plug tightened to the specified
torque as soon as possible.
4. Install the spark plug caps, the cyl-
inder head covers and the screws. Tightening torque:
Spark plug:
20 Nm (2.0 mákg)
Page 46 of 87
R
6-8
PERIODIC MAINTENANCE AND MINOR REPAIR
/Net/layout8/layout_G2/work/Imai_work/OM-PS/AA9149_XV535-E6/English/E-6.frame
1. Engine oil drain bolt
3. Remove the drain bolt and drain
the oil.
1. Oil filter cover
2. Bolt (´ 3)
4. Remove the oil filter bolts, oil filter
and O-ring.
5. Install the drain bolt and tighten it
to the specified torque.
6. Install the new oil filter, new O-ring
and the filter cover. Then tighten the
oil filter bolts to the specified torque. Tightening torque:
Drain bolt:
43 Nm (4.3 mákg)
Tightening torque:
Oil filter bolts:
10 Nm (1.0 mákg)
1. O-ring
2. Oil filter element
NOTE:
Make sure the O-ring is seated proper-
ly.
7. Fill the engine with oil. Install the
oil filler cap and tighten it.
Recommended oil:
See page 8-1.
Oil quantity:
Total amount:
3.2 L
Periodic oil change:
2.6 L
With oil filter replacement:
2.8 L
Page 47 of 87

L
6-9
PERIODIC MAINTENANCE AND MINOR REPAIR
/Net/layout8/layout_G2/work/Imai_work/OM-PS/AA9149_XV535-E6/English/E-6.frame
EC000066
CAUTION:
lDo not put in any chemical addi-
tives. Engine oil also lubricates
the clutch and additives could
cause clutch slippage.
lBe sure no foreign material en-
ters the crankcase.
8. Start the engine and warm it up for
a few minutes. While warming up,
check for oil leakage. If oil leakage
is found, stop the engine immedi-
ately and check for the cause.
1. Final gear oil drain bolt
2. Final gear oil
3. Final gear oil filler bolt
4. Correct level
EAU02943
Final gear oil
EW000066
Do not let foreign material enter the
final gear case. Be sure oil does not
get on the tire or wheel.
Oil level inspection
1. Place the motorcycle on a level
place and hold it in an upright posi-
tion. The engine should be cool at
ambient temperature.2. Remove the oil filler bolt and
check the oil level. The oil level
should be at the brim of the filler
hole. Add the recommended oil if
necessary.
Oil replacement
1. Place an oil pan under the final
gear case.
2. Remove the oil filler bolt and drain
bolt to drain the oil.
3. Install and tighten the drain bolt to
the specified torque.
4. Fill the gear case to the brim of the
filler hole with the recommended
oil. Tightening torque:
Drain bolt:
23 Nm (2.3 mákg)
Page 48 of 87

R
6-10
PERIODIC MAINTENANCE AND MINOR REPAIR
/Net/layout8/layout_G2/work/Imai_work/OM-PS/AA9149_XV535-E6/English/E-6.frame
NOTE:
ÒGL-4Ó is a quality and additive rating.
Hypoid gear oils rated ÒGL-5Ó or ÒGL-6Ó
may also be used.
5. Install and tighten the filler bolt to
the specified torque.
6. After replacing the final gear oil, be
sure to check for oil leakage. Final gear case capacity:
0.19 L
Recommended oil:
SAE 80 API GL-4 Hypoid gear oil
If desired, an SAE 80W90 hypoid
gear oil may be used for all
conditions.
Tightening torque:
Oil filler bolt:
23 Nm (2.3 mákg)
1. Fuel tank
2. Bolt (´ 3)
EAU02998
Air filter
The air filter should be cleaned at the
specified intervals. It should be cleaned
more frequently if you are riding in un-
usually wet or dusty areas.
1. Remove the seats. (See page 3-7
for seat removal and installation
procedures.)
2. Remove the fuel tank bolts.
1. Screw
3. Lift the front of the fuel tank up-
ward and position it away from the
air filter. (Do not remove the fuel
tank.)
EW000071
lSupport the fuel tank carefully
during this procedure.
lDo not tilt the fuel tank too
much or pull it too hard be-
cause the fuel hose connec-
tions may become loose
causing fuel leakage.
4. Remove the air filter case cover
screw.
Page 81 of 87
L
8-5
SPECIFICATIONS
/Net/layout8/layout_G2/work/Imai_work/OM-PS/AA9149_XV535-E6/English/E-8.frame
EAU01064
HOW TO USE THE CONVERSION TABLE
All specification data in this manual are listed in SI and
METRIC UNITS.
Use this table to convert METRIC unit data to IMPERIAL
unit data.
Ex.
METRIC MULTIPLIER IMPERIAL
**mm´0.03937=
**in
2 mm´0.03937=
0.08 in
CONVERSION TABLE
METRIC TO IMPERIAL
Metric unit Multiplier Imperial unit
Torquemákg
mákg
cmákg
cmákg7.233
86.794
0.0723
0.8679ftálb
inálb
ftálb
inálb
Weightkg
g2.205
0.03527lb
oz
Speed km/hr 0.6214 mph
Distancekm
m
m
cm
mm0.6214
3.281
1.094
0.3937
0.03937mi
ft
yd
in
in
Volume /
Capacitycc (cm
3)
cc (cm3)
lt (liter)
lt (liter)0.03527
0.06102
0.8799
0.2199oz (IMP liq.)
cuáin
qt (IMP liq.)
gal (IMP liq.)
Misc.kg/mm
kg/cm
2
Centigrade (°
C)55.997
14.2234
9/5 + 32 lb/in
psi (lb/in
2)
Fahrenheit (°
F)