SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual ENGINE GENERAL INFORMATION AND DIAGNOSIS 6-27
Engine noise
Note : Before
checking mechani-
cal noise, make sure 
that :
Specified spark 
plug is used.
Specified fuel is 
used.Improper valve lash Valve

Page 397 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual 6-28 ENGINE GENERAL INFORMATION AND DIAGNOSIS
Poor gasoline mile-
age Leaks or loose connection of high-tension 
cordHigh-tension cords in Section 6F1.
Faulty spark plug (improper gap, heavy 
deposits

Page 398 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual ENGINE GENERAL INFORMATION AND DIAGNOSIS 6-29
Excessive detona-
tion
(Engine makes con-
tinuously sharp 
metallic knocks that 
change with throttle 
opening. Sounds 
like pop corn pop-
ping.)Faulty sp

Page 399 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual 6-30 ENGINE GENERAL INFORMATION AND DIAGNOSIS
Improper engine 
idling or engine fails 
to idleFaulty spark plug Spark plugs in Section 6F1.
Leaky or disconnected high-tension cord High-tension cords i

Page 401 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual 6-32 ENGINE GENERAL INFORMATION AND DIAGNOSIS
✱THROTTLE POS 
(ABSOLUTE THROTTLE 
POSITION)Ignition switch 
ON/engine 
stoppedThrottle valve fully closed 7 – 18%
Throttle valve fully open 70 – 90

Page 402 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual ENGINE GENERAL INFORMATION AND DIAGNOSIS 6-33
SCAN TOOL DATA DEFINITIONS :
FUEL SYSTEM (FUEL SYSTEM STATUS)
Air/fuel ratio feedback loop status displayed as either open or closed loop. Open indicates

Page 403 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual 6-34 ENGINE GENERAL INFORMATION AND DIAGNOSIS
IGNITION ADVANCE (IGNITION TIMING ADVANCE FOR NO.1 CYLINDER, °)
Ignition timing of NO.1 cylinder is commanded by ECM. The actual ignition timing should b

Page 404 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual ENGINE GENERAL INFORMATION AND DIAGNOSIS 6-35
RADIATOR FAN (RADIATOR FAN CONTROL RELAY, ON/OFF)
ON : Command for radiator fan control relay operation being output.
OFF : Command for relay operation no