2000 SUZUKI SWIFT temperature sensor

[x] Cancel search: temperature sensor

Page 25 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual 0A-22 GENERAL INFORMATION
ABBREVIATIONS AND SYMBOLS MAY BE USED IN THIS MANUAL
ABBREVIATIONS
AABS Anti-lock Brake System
EEFE Heater Early Fuel Evaporation Heater 
(Positive Temperature Coefficient,

Page 67 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual 1B-2 AIR CONDITIONING (OPTIONAL)
REMOVING MANIFOLD GAUGE SET ......  1B-26
LEAK TEST................................................  1B-26
LIQUID LEAK DETECTORS ..................  1B-26
ON-VEHICLE S

Page 70 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual AIR CONDITIONING (OPTIONAL) 1B-5
DIAGNOSIS
GENERAL DIAGNOSIS TABLE
Condition Possible Cause Correction
Cool air won’t come 
out (A/C system won’t 
operative)No refrigerant Perform recover, evacuat

Page 71 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual 1B-6 AIR CONDITIONING (OPTIONAL)
Cool air won’t come 
out or insufficient 
cooling (A/C system 
normal operative)Insufficient or excessive charge of 
refrigerantCheck charge of refrigerant and syste

Page 81 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual 1B-16 AIR CONDITIONING (OPTIONAL)
ELECTRICAL DIAGNOSIS
WIRING DIAGRAM
1. Blower fan motor 6. Radiator/condenser cooling fan relay No.2 11. Ignition switch 16. Main fuse box
2. Blower fan motor resisto

Page 83 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual 1B-18 AIR CONDITIONING (OPTIONAL)
System Circuit
Terminal arrangement of ECM coupler (Viewed from harness side)
1. Blower fan motor 8. Main relay A. To “HTR” fuse (25 A) in circuit fuse box
2. Blo

Page 84 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual AIR CONDITIONING (OPTIONAL) 1B-19
ECM Voltage Values Table for Relation of A/C Control
Terminal Wire Circuit Measurement 
groundNormal value Condition
C41-1 PNK/BLK Compressor magnet 
clutch outputGro

Page 97 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual 1B-32 AIR CONDITIONING (OPTIONAL)
COOLING UNIT (EVAPORATOR)
REMOVAL
1) Disconnect negative (–) cable at battery.
2) Recover refrigerant from A/C system by referring to
“RECOVERY” in this section
Page:   1-8 9-16 17-24 25-32 32 next >