Downloaded from www.Manualslib.com manuals search engine AIR CONDITIONING
Connecting pipes
62
62-7
SCENIC
Disconnect the battery.
Drain the R134a refrigerant circuit using the filling equipment (refer to the procedure described in the "Air
Conditioning" manual).
HIGH PRESSURE PIPE BETWEEN THE
DEHYDRATION CANISTER AND THE PRESSURE
REDUCING VALVE
REMOVAL
Remove the right hand cowl vent grille.
Slacken the left hand cowl vent grille.
Remove the scuttle,
Detach the pipe from its mountings.
Remove the high pressure hose.
Fit plugs to prevent any moisture penetration.
REFITTING
Refitting is the reverse of removal.
Check the condition of the seals and lubricate with
PLANETELF PAG 488 (approximately 2 g).
When changing a pipe, add 10 ml of PLANETELF
PAG 488 oil or when a pipe bursts (rapid leak), add
100 ml.HIGH PRESSURE PIPE BETWEEN THE
DEHYDRATION CANISTER AND THE CONDENSER
REMOVAL
Remove:
– the mounting bolt on the dehydration canister,
– the mounting bolt on the condenser.
Fit plugs to prevent any moisture penetration.
Remove the high pressure hose.
REFITTING
Refitting is the reverse of removal.
Check the condition of the seals and lubricate with
PLANETELF PAG 488 (approximately 2 g).
When changing a pipe, add 10 ml of PLANETELF
PAG 488 oil or when a pipe bursts (rapid leak), add
100 ml.
PRF6205
PRF6206