4B22 : CHECK LED OF TRANSMITTER.
1) Press either the LOCK/ARM or UNLOCK/
DISARM button six times to synchronize with the
keyless entry control module.
2) Press the LOCK/ARM button.
:Does the LED blink one time?
: Go to step4B23.
: Replace transmitter.
4B23 : CHECK LED OF TRANSMITTER.
Keep the LOCK/ARM button pressed.
:Does the LED blink one time and then
turn on?
: Go to step4B24.
: Replace transmitter.
4B24 : CHECK LED OF TRANSMITTER.
Press the UNLOCK/DISARM button.
:Does the LED blink one time?
: Go to step4B25.
: Replace transmitter.
4B25 : CHECK LED OF TRANSMITTER.
Keep the UNLOCK/DISARM button pressed.
:Does the LED blink two times?
: Go to step4B26.
: Replace transmitter.
4B26 : CHECK POWER DOOR LOCK
FUNCTION.
Perform lock and unlock function of power door
lock with transmitter.
:Does it function normally?
: Go to step4B27.
: Replace transmitter.4B27 : CHECK ON/OFF SELECT HORN
SIGNAL.
Press the LOCK/ARM or UNLOCK/DISARM but-
ton.
:Does the horn signal chirp?
: Go to step4B28.
: Keep both LOCK/ARM and UNLOCK/
DISARM buttons pressed for more than
1.5 seconds. Go to step4B28.
4B28 : CHECK ON/OFF SELECT HORN
SIGNAL.
Keep both LOCK/ARM and UNLOCK/DISARM
buttons pressed for more than 1.5 seconds.
:Does the horn signal chirp two
times?
: Go to step4B29.
: Replace transmitter.
4B29 : CHECK ON/OFF SELECT HORN
SIGNAL.
Press LOCK/ARM or UNLOCK/DISARM button.
:Does the horn signal chirp?
: Replace transmitter.
: Go to step4B210.
4B210 : CHECK ON/OFF SELECT HORN
SIGNAL.
Keep both LOCK/ARM and UNLOCK/DISARM
buttons pressed for more than 1.5 seconds.
:Does the horn signal chirp one time?
: Go to step4B211.
: Replace transmitter.
4B211 : CHECK ON/OFF SELECT HORN
SIGNAL.
Press LOCK/ARM and UNLOCK/DISARM button.
:Does the horn signal chirp?
: Go to step4B212.
: Replace transmitter.
54
6-2[T4B2]DIAGNOSTICS
4. Keyless Entry System
2. DIAGNOSTICS ITEM 1
4F21 : SELECT HORN SIGNAL OPERA-
TION.
Keep both LOCK/ARM and UNLOCK/DISARM
buttons pressed for more than 1.5 seconds.
:Does the horn chirp one time?
: Go to step4F22.
: Replace keyless entry control module.
4F22 : CHECK HORN SIGNAL OUTPUT
SIGNAL.
1) Disconnect connector from keyless entry con-
trol module.
2) Measure voltage between keyless entry control
module connector (B176) and chassis ground.
Connector & terminal
(B176) No. 12 (+) Ð Chassis ground (þ):
B6M0958A
:Is the voltage more than 10 V?
: Go to step4F23.
: Go to step4F26.4F23 : CHECK HORN RELAY.
1) Remove horn relay from main fuse box.
2) Check continuity between horn relay terminals.
Terminals
No. 1 Ð No. 2:
B6M1348B
:Does continuity exist?
: Replace horn relay.
: Go to step4F24.
4F24 : CHECK HORN RELAY.
Check continuity between horn relay terminals.
Terminals
No. 3 Ð No. 4:
B6M1349B
:Does continuity exist?
: Go to step4F25.
: Replace horn relay.
63
[T4F2]6-2DIAGNOSTICS
4. Keyless Entry System