2) Connect voltmeter positive lead to negative battery cable
clamp. Connect voltmeter negative lead to negative battery post. Crank
engine and observe voltmeter reading. If voltage is detected, repair
poor contact between cable clamp and post. Perform same procedure to
positive battery post and cable clamp.
Ground Connection Resistance Test
Connect voltmeter negative lead to negative battery post.
Connect voltmeter positive lead to engine block, near negative battery
cable grounding point. Crank engine and observe voltmeter reading. If
voltmeter reading indicates more than 0.2 volt, repair poor ground
connection or replace ground cable.
Starter Ground Connection Resistance Test
Connect voltmeter negative lead to negative battery post.
Connect voltmeter positive lead to starter housing. Crank engine and
observe voltmeter reading. If voltmeter reading indicates more than 0.
2 volt, repair poor starter-to-ground connection.
Positive Battery Cable Resistance Test
1) Remove starter heat shield (if equipped) to gain access t\
o
starter solenoid connections. Connect voltmeter negative lead to
starter solenoid battery terminal and voltmeter positive lead to
positive battery post.
2) Crank engine and observe voltmeter reading. If voltage
reads more than 0.2 volt, correct poor connection between battery
cable and starter solenoid or replace positive battery cable.
SOLENOID CIRCUIT TEST
NOTE: Perform SOLENOID CIRCUIT TEST before testing starter relay
and starter relay circuit. Ensure A/T is in Park position or
M/T is in Neutral position and parking brake is applied.
1) Disable vehicle ignition and fuel systems. See
DISABLING/ENABLING IGNITION & FUEL SYSTEMS.
2) Ensure battery is fully charged. Ensure solenoid
connections are not loose or corroded. Remove starter relay from Power
Distribution Center (PDC). Refer to PDC cover for proper relay
location. PDC is located in engine compartment.
3) Connect a remote starter switch or jumper wire between
starter relay socket terminal No. 87 and positive battery post. See
Fig. 1 or 2. If engine cranks, solenoid and starter are good. Go to
STARTER RELAY TEST.
4) If engine fails to crank, or if solenoid chatters, check
wiring and connectors from starter relay socket to starter solenoid
terminal. Repair any loose or corroded connections. If engine still
fails to crank, remove starter and proceed to SOLENOID TEST under
BENCH TESTING.
STARTER RELAY TEST
NOTE: Perform SOLENOID CIRCUIT TEST before testing starter relay.
Remove starter relay from Power Distribution Center (PDC).
Refer to PDC cover for proper relay location. PDC is located in engine
compartment. Connect 12-volt power source to starter relay terminal
No. 86 and ground terminal No. 85. See Fig. 1 or 2. Using ohmmeter,
check continuity across starter relay terminals No. 30 and 87. If
continuity is not present, replace starter relay.