1998 SSANGYONG MUSSO ignition

[x] Cancel search: ignition

Page 1391 of 1463

SSANGYONG MUSSO 1998  Workshop Repair Manual SECTION 9L
GLASS  AND  MIRRORS
Caution: Disconnect the negative battery cable before removing or installing any electrical unit or when a
tool or equipment could easily come in contact with exposed el

Page 1403 of 1463

SSANGYONG MUSSO 1998  Workshop Repair Manual GLASS AND MIRRORS  9L-13
Check & Service
If reflection ratio is not adjusted automatically during night
driving when AUTO switch is pressed, check each connectors
for proper connection and power flow

Page 1415 of 1463

SSANGYONG MUSSO 1998  Workshop Repair Manual SECTION 9P
DOORS
Caution: Disconnect the negative battery cable before removing or installing any electrical unit or when a
tool or equipment could easily come in contact with exposed electrical termi

Page 1431 of 1463

SSANGYONG MUSSO 1998  Workshop Repair Manual SECTION 9T
REMOTE  KEYLESS  ENTRY  AND
ANTI-THEFT  SYSTEM
Caution: Disconnect the negative battery cable before removing or installing any electrical unit or when a
tool or equipment could easily come

Page 1438 of 1463

SSANGYONG MUSSO 1998  Workshop Repair Manual SECTION 9U
CONTROL  UNITS  AND  SYSTEM
Caution: Disconnect the negative battery cable before removing or installing any electrical unit or when a
tool or equipment could easily come in contact with ex

Page 1440 of 1463

SSANGYONG MUSSO 1998  Workshop Repair Manual CONTROL UNITS AND SYSTEM  9U-3
FUNCTION DESCRIPTION
STICS
Operating Functions
NO.ApplicationDeseription
1Wiper INT sensing vehicle speed
lBy operating INT time control volume, variable time will be
ch

Page 1441 of 1463

SSANGYONG MUSSO 1998  Workshop Repair Manual 9U-4  CONTROL UNITS AND SYSTEM
NO. ApplicationDeseription
13Ignition key hole illuminationlCoupled with door switch, ignition key hole illumination lamp will
turn on when the driver’s door is opened

Page 1445 of 1463

SSANGYONG MUSSO 1998  Workshop Repair Manual 9U-8  CONTROL UNITS AND SYSTEM
11. Central door lock
T1 : within 0.2 sec.
T2 : 0.5±0.1
12. Coupled with REKES mode
T1 : 0.05±0.02 sec. (lock signal)
T2 : 0.1±0.02 sec. (unlock signal)
T3 : within 0