Page 1171 of 1463

Model
Type
Gear Ratio
Oil
Manufacturer
WeightPart-Time 4408 (E)
E.S.O.F. Type
1 : 1
2.48 : 1
ATF S-3, S-4 or DEXRON II, III
1.2 L
Check : Every 15,000 km
Replace : Every 50,000 km
Borg Warner
30 kg
SECTION 5D1
TRANSFER CASE (PART TIME 4408)
TABLE OF CONTENTS
SPECIFICATIONS
GENERAL SPECIFICATIONS
Caution: Disconnect the negative battery cable before removing or installing any electrical unit or when a
tool or equipment could easily come in contact with exposed electrical terminals. Disconnecting this
cable will help prevent personal injury and damage to the vehicle. The ignition must also be in LOCK
unless otherwise noted.
Specifications . . . . . . . . . . . . . . . . . . . . . . . 5D1-1
General Specifications . . . . . . . . . . . . . . . . . 5D1-1
Schematic and Routing Diagram . . . . . . . . 5D1-2
Part Time Transfer Case - 4408 . . . . . . . . . . 5D1-2
Diagnosis . . . . . . . . . . . . . . . . . . . . . . . . . . 5D1-3
Self-Diagnosis . . . . . . . . . . . . . . . . . . . . . . 5D1-4
System Description . . . . . . . . . . . . . . . . . . . . 5D1-4
Self-Diagnosis Test . . . . . . . . . . . . . . . . . . . . 5D1-8Diagnostic Diagram . . . . . . . . . . . . . . . . . . . 5D1-9
Maintenance and Repair . . . . . . . . . . . . . 5D1-10
On-Vehicle Service . . . . . . . . . . . . . . . . . . . 5D1-10
Maintenance of Transfer Case Lubricant . . 5D1-10
Transfer Case . . . . . . . . . . . . . . . . . . . . . . . 5D1-11
Unit Repair . . . . . . . . . . . . . . . . . . . . . . . . 5D1-14
Transfer Case . . . . . . . . . . . . . . . . . . . . . . . 5D1-14
Transfer Case Control Unit (TCCU) . . . . . . 5D1-36
High
Low
Specification
Capacity
Lubrication ApplicationDescription
Page 1275 of 1463

SECTION 7B/C
MANUAL CONTROL /
SEMIAUTO TEMPERATURE CONTROL
HEATING, VENTILATION AND AIR
CONDITIONING SYSTEM
Caution: Disconnect the negative battery cable before removing or installing any electrical unit or when a
tool or equipment could easily come in contact with exposed electrical terminals. Disconnecting this cable
will help prevent personal injury and damage to the vehicle. The ignition must also be in LOCK unless otherwise
noted.
Specifications . . . . . . . . . . . . . . . . . . . . . . 7B/C-2
Cooling Capacity . . . . . . . . . . . . . . . . . . . . 7B/C-2
Compressor . . . . . . . . . . . . . . . . . . . . . . . . 7B/C-2
Condenser . . . . . . . . . . . . . . . . . . . . . . . . . 7B/C-2
Receiver Drier . . . . . . . . . . . . . . . . . . . . . . 7B/C-2
Dual Pressure Switch . . . . . . . . . . . . . . . . . 7B/C-2
Evaporator . . . . . . . . . . . . . . . . . . . . . . . . . 7B/C-3
Heater Unit . . . . . . . . . . . . . . . . . . . . . . . . . 7B/C-3
Fastener Tightening Specifications . . . . . . . 7B/C-3
Diagnosis . . . . . . . . . . . . . . . . . . . . . . . . . 7B/C-4
Defectives in Fan Motor Circuit . . . . . . . . . . 7B/C-5
Defectives in Compressor Circuit . . . . . . . . 7B/C-5
TABLE OF CONTENTS
Component Locator . . . . . . . . . . . . . . . . . 7B/C-6
Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . 7B/C-6
Air Conditioner System . . . . . . . . . . . . . . 7B/C-8
Diesel Engine . . . . . . . . . . . . . . . . . . . . . . . 7B/C-8
Gasoline Engine . . . . . . . . . . . . . . . . . . . . . 7B/C-9
Maintenance and Repair . . . . . . . . . . . . 7B/C-10
Refrigerant Charging . . . . . . . . . . . . . . . . 7B/C-10
Condenser . . . . . . . . . . . . . . . . . . . . . . . . 7B/C-14
Receiver Drier . . . . . . . . . . . . . . . . . . . . . 7B/C-18
Compressor . . . . . . . . . . . . . . . . . . . . . . . 7B/C-21
Heater and Air Conditioner Control Box . . 7B/C-25
Page 1279 of 1463

MANUAL & SEMIAUTO-HVAC 7B/C-5
Action
Clean oily plate using cleaning agent.
Charge battery or check for cause.
Check wire continuity
Check A/C switch and fan switch for continuity and ground.
DEFECTIVES IN FAN MOTOR CIRCUIT
Fan Motor Does Not Run
Checks
Blown fuse
Battery voltage is low
Faulty wiring
Faulty groundAction
Check for short and replace fuse.
Check battery voltage.
Check connectors’ connection.
Do not apply grease. This can cause voltage down.
Remove body painting and completely ground,
Tighten ground bolts and make sure body ground connection.
Checks
Blown resister temperature fuse
Air leakage in parts connection
Action
Replace resistor.
Check heater, cooling unit and blower for proper connection.
Fan Motor Runs in ‘4’position Only (‘3’, ‘2’, ‘1’ : Does Not Run)
Frosted Evaporator
DEFECTIVES IN COMPRESSOR CIRCUIT
Compressor Does Not Run
Checks
Faulty thermo ampAction
Frosted evaporator reduces cooling capacity.
Off compressor and maximize blowing capacity
Checks
Faulty high/low pressure
Faulty A/C relayAction
Check compressor magnet voltage supply.
A/C relay.
Checks
Oily clutch plate
Low voltage
Faulty electric connection or operation
Magnetic Clutch Slips /Idles
Checks
Clogged or blocked intake grilleAction
Clogged or blocked intake grille reduces blowing capacity.
Motor Runs With Poor Blowing
Checks
Excessive clearance between
Clutch plate and clutch coilAction
Adjust clutch clearance (0.2-0.6mm).
Magnetic Clutch Plays By Hand Only