c11010.0
AIR CONDITIONING
Fault finding charts
62
KANGOO
ALL TYPES
AFTER
REPAIR
CHART 7DEICING/DEMISTING PERFORMANCE POOR
NOTES
See CHART 1.
yes
yes
yes
See CHART 2.
no
yes
See CHART 3.
no
yes
no
Check that the recirculation flap is not
jammed in the recirculated air position
(see CHART 11).
Repair if necessary.
Is it a heater performance problem?
Is it an air flow problem?
Is it an air distribution problem?
Check that the windows are clean on the inside.
End of fault finding.no
End of fault finding.no
Check that the air extractors
are not blocked.
Repair if necessary.
Does the fault persist?
Ensure that there are no water leaks into the
passenger compartment which would
significantly increase the humidity level and
reduce the effectiveness of the demisting.
Locate the leak and repair it.
Does the fault persist?
Check that the components which were removed are connected correctly.
Check that the system operates correctly.
62-27