NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual Trouble Diagnoses
POWER ANTENNA
Symptom Possible causes Repair order
Power antenna does not oper-
ate.1. 10A fuse
2. Radio signal
3. Grounds
E25andE40
1. Check 10A fuse (No.56, located in fuse and fus

Page 200 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual System Description
With ignition switch in ON or START position, power is supplied
+through 7.5A fuse [No.
8, located in the fuse block (J/B)]
+to power window relay terminalj
1.
The power window rela

Page 207 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual Trouble Diagnoses
Symptom Possible cause Repair order
None of the power windows can be
operated using any switch.1. 7.5A fuse, 40A fusible link and
M92circuit breaker
2. Grounds
M30andM19orM98
3. Powe

Page 208 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual System Description
Power is supplied at all times
+through 40A fusible link (Letter
e, located in the fuse and fusible link box)
+to circuit breaker terminalj
1
+through circuit breaker terminalj2
+to

Page 236 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual DIAGNOSTIC PROCEDURE 7
(Key switch check)
CHECK KEY SWITCH INPUT SIGNAL.
Check voltage between control unit termi-
nalj
7and ground.
Refer to wiring diagram in EL-215 (LHD),
EL-219 (RHD).
NG
cOK
Key s

Page 241 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual Trouble Diagnoses
SYMPTOM CHART
Symptom Possible cause Diagnoses/service order
No doors can be
locked or unlocked
by remote control
operation.Hazard reminder
also does not oper-
ate either.1. Remote c

Page 251 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual DIAGNOSTIC PROCEDURE 3
Self-diagnostic results:
``CHAIN OF ECM-IMMU displayed on CONSULT screen
Con®rm SELF-DIAGNOSTIC
RESULTS ``CHAIN OF ECM-
IMMU displayed on CONSULT
screen.
OK
CHECK POWER SUP

Page 257 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual DIAGNOSTIC PROCEDURE 9
Security indicator check
CHECK INDICATOR CIRCUIT.
1. Disconnect NATS IMMU connector.
2. Check voltage between NATS IMMU
terminalj
6and ground.
Battery voltage should exist.
OK
c