MITSUBISHI MONTERO 1998  Service Manual wiring harness as necessary. If continuity exists, go to next step.
         5) Reconnect PCM connector. Turn ignition switch to ON
position. Check voltage between chassis ground and MDP sensor
connec

Page 781 of 1501

MITSUBISHI MONTERO 1998  Service Manual          ON-VEHICLE TESTING
          GENERATOR TO BATTERY CONTINUITY TEST
NOTE:    Check generator wiring harness connections and drive belt
         tension and ensure battery is fully charged befor

Page 782 of 1501

MITSUBISHI MONTERO 1998  Service Manual          GENERATOR OUTPUT TEST
NOTE:    A slightly discharged battery should be used, as a fully
         charged battery may not allow full generator output.
         1) Turn ignition off. Disconnect

Page 783 of 1501

MITSUBISHI MONTERO 1998  Service Manual See Fig. 1 . Connect negative voltmeter lead to ground.
         2) Disconnect generator output wire from terminal "B".
Install a 100-amp ammeter in series with terminal "B" and disconnected
output le

Page 795 of 1501

MITSUBISHI MONTERO 1998  Service Manual H - TESTS W/O CODES 
1998 Mitsubishi Montero
         1998 ENGINE PERFORMANCE
          Mitsubishi - Trouble Shooting - No Codes
          Diamante, Eclipse, Galant, Mirage, Montero, Montero Sport,

Page 796 of 1501

MITSUBISHI MONTERO 1998  Service Manual       *  Check power supply to PCM.
       *  Check fuel pressure.
       *  Check ignition timing.
       *  Check for disconnected or damaged vacuum hoses.
       *  Check for control relay malfunct

Page 797 of 1501

MITSUBISHI MONTERO 1998  Service Manual       *  Check idle air control (DC) motor (if applicable).
       *  Check idle air control (stepper) motor (if applicable).
       *  Check for fuel injector malfunction.
       *  Check for power t

Page 798 of 1501

MITSUBISHI MONTERO 1998  Service Manual indicates a fault has been located.
         Use a DVOM to pinpoint faults. See J - PIN VOLTAGE CHARTS
article. When monitoring voltage, ensure ignition switch is in ON