Page 2 of 61
24-80
       If the voltage does not change or only changes 
slowly the following malfunctions are possible:  
     
Slits or holes in probe head are blocked.
     Oxygen sensor has been subjected to 
excessive thermal stress. 
     Contact resistance in signal wire or Ground 
(GND) wire. 
     Oxygen sensor too cold; sensor heater not 
working. 
     Oxygen sensor damaged by contact spray or 
similar product. (The contact spray is drawn 
through the fine cavities in the electrical wiring 
as a result of thermal fluctuations and capillary 
effect.) 
     Oxygen sensor damaged by silicone vapors. 
(The engine draws in traces of any silicone-
based sealants that may have been used. The 
silicone does not burn and damages the oxygen 
sensor.) 
Pa
ge 2 of 61 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.2 
     
        
        Page 4 of 61
24-82
      
Notes:  
     
For the defined troubleshooting procedure, it is 
possible to switch off the oxygen sensor control 
by selecting Display Group 99 in "Basic Setting" 
mode and to switch it on again by selecting 
Display Group 99 in "Read Measuring Value 
Block" mode. 
     After selecting Display Group 99 (either in 
"Basic Setting" mode or in "Read Measuring 
Value Block" mode) it is possible to switch back 
and forth between function 04 ("Basic Setting") 
and function 08 "Read Measuring Value Block") 
by pressing buttons 4 and 8 on VAG1551 scan 
tool. 
     When exiting the "Basic Setting" mode (function 
04) the oxygen sensor control is automatically 
switched on again. 
     
Test conditions  
     Perform road test and do not erase DTC 
memory. 
     Coolant temperature at least 85 C (Display 
group 004, display field 3) 
Pa
ge 4 of 61 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.2 
     
        
        Page 41 of 61
24-113
      
Continuation  
      If the specified value in display group 037 and 
038, display 3 or 4 is not obtained:  
     
-  Check exhaust system and catalytic converter 
for leaks (check clamps and exhaust for 
damage) 
     
-  If the difference of the values in measuring 
blocks, display fields 3 (oxygen sensor 
correction value) is to large (e.g.:+500 ms, -500 
ms), it is possible that the oxygen sensor are 
interchanged (mixed up). 
      If none of the causes are identified:  
     
-  Replace particular oxygen sensor "before" 
catalytic converter. 
Pa
ge 41 of 61 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.2 
     
        
        Page 42 of 61
24-114
      
Oxygen sensor heater for oxygen 
sensor, checking
 
     
Note:  
     The oxygen sensor heating circuit is monitored 
by the On Board Diagnostic (OBD). Check DTC 
memory  Page 01-15
 . 
     
-  Connect vehicle diagnostic, testing and 
information system VAS5051 or VAG1551 scan 
tool and select engine electronics control 
module by entering address word "01"   Page 
01
-9 . When doing this the engine must be at 
idle. 
Rapid data transfer 
HELP
Select function XX
    
Indicated on display  
-  Press buttons -0- and -8- to select function "Read Measuring Value 
Block" and confirm entry with -Q- button. 
Read Measurin
g Value Block 
Input display group number XXX
    
Indicated on display  
-  Press buttons -0-, -4- and -1- to select "display group number 041" and 
confirm entry with -Q- button. 
Read Measuring Value Block 41  
1 
2 
3 
4
    
Indicated on display  
Pa
ge 42 of 61 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.2