Page 11 of 61
24-89
      
If the specified values in display fields 1 
and/or 3 do not match the specifications, or if 
the readout does not fluctuate by at least 2 
%:  
     
-  Check oxygen sensor heater   Page 24
-114
 .
     
-  Check oxygen sensor signal wire and activation 
 Page 24
-122
 . 
     
-  Check intake system for leaks and eliminate 
false air   Page 24
-76
 . 
     
-  Check fuel pressure regulator   Page 24
-33
 .
     
-  Fuel return line kinked or plugged.
     
- 
Press  button.      
-  Press button -0- and -6- to select function "End 
Output" and confirm with -Q- button. 
     
-  Switch ignition off.
Pa
ge 11 of 61 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.2 
     
        
        Page 47 of 61
24-119
      
- Start engine.
     
   Specified value: approx. battery voltage 
(fluctuating) 
     
Note:  
     At certain points in the operating range the 
engine control module continuously "switches" 
the Ground (GND) connection to the oxygen 
sensor heater. That means, it repeatedly 
connects and disconnects the Ground (GND) 
connection at these points. For this reason the 
voltage reading on the tester may fluctuate. 
     
-  Switch ignition off.
      If there is no voltage reading:  
     
-  Connect VAG1598/31 test box to wiring harness 
for engine control module. Do not connect to the 
engine control module itself   Page 24
-20
 . 
    
-  Check for open circuits in the following wiring connection:
Pa
ge 47 of 61 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.2 
     
        
        Page 50 of 61
24-122
      
Oxygen sensor signal wire and 
activation, checking
 
     
Note:  
     The oxygen sensor signal is monitored by the 
OBD system. 
     
-  Check DTC memory   Page 01
-15
 .
     
-  If a oxygen sensor malfunction is displayed and 
the oxygen sensor heater is OK, disconnect 
harness connector for relevant oxygen sensor. 
      Component location of 4-pin harness connector 
of oxygen sensor   Page 24
-5 .  
    
If the Specified value is not obtained, check oxygen sensor wiring:  -  Test voltage by connecting hand-held multimeter Fluke 83 (or 
equivalent) (measuring range 2 V) between sockets 3 and 4 of 
connector on wiring harness. 
- 
Switch ignition on. Specified value: 450   50 mV.   Bank 1, Sensor 1   Page 24
-123
 .
   Bank 1, Sensor 2   Page 24
-125
 .
   Bank 2, Sensor 1   Page 24
-127
 .
   Bank 2, Sensor 2   Page 24
-129
 .
Pa
ge 50 of 61 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.2