24-109
 
  
Display fields  
  
1   2   3   4  
Display group 037: Diagnostic oxygen sensor control (Bank 1)  
Display   xxx %   x.xxx Volt   xxx ms  
Test ON  
Indicated  Engine 
load  Oxygen sensor voltage behind 
catalytic converter, Bank 1  Correction value between 
oxygen sensor 1 and sensor 
2, bank 1  Diagnostic condition  
Work 
range  15.0 - 
175.0 %  0.000 - 1.000 V   -1200 - 1200 ms  
Test OFF  
Test ON  
SYST. OK  
SYST. not OK  
Specified 
value  15.0 - 
25.0 %  0.000 - 1.000 V   -500 - 500 ms  
SYST. OK  
Note  
  
If specified value is not 
obtained: Evaluation display 
field 2   Page 24
-112
   
If specified value is 
obtained: Continuation   
Page 24
-113
   
If "SYST. not OK" is 
displayed: Check DTC 
memory  Page 01
-15
   
or Continue   Page 24-113
   
Note for display field 3:  
Oxygen sensor control behind catalytic converter is superior to oxygen sensor control before catalytic converter and is the 
primary control. It corrects slight changes in the mixture (i.e. enrichment or thinning) by holding the oxygen sensor control 
before catalytic converter at its higher or lower point for a specific time (duration). If this time is in the positive range (i.e. 50 
ms), mixture is shifted in the -enrich- direction. If this time is in the negative range (i.e. 50 ms), mixture is shifted in the -lean- 
Pa
ge 35 of 61 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.2 
24-111
 
  
Display fields  
  
1   2   3   4  
Display group 038: Diagnostic oxygen sensor control (Bank 2)  
Display   xxx %   x.xxx Volt   xxx ms  
Test ON  
Indicated  Engine 
load  Oxygen sensor voltage behind 
catalytic converter, Bank 2  Correction value between 
oxygen sensor 1 and sensor 
2, bank 2  Diagnostic condition  
Work 
range  15.0 - 
175.0 %  0.000 - 1.000 V   -1200 - 1200 ms  
Test OFF  
Test ON  
SYST. OK  
SYST. not OK  
Specified 
value  15.0 - 
25.0 %  0.000 - 1.000 V   -500 - 500 ms  
SYST. OK  
Note  
   If specified value is not obtained: 
Evaluation display field 2   
Page 24
-112
   
If specified value is obtained: 
Continuation  Page 24
-113
   
If "SYST. not OK" is 
displayed: Check DTC 
memory  Page 01
-15
   
or Continue   Page 24-113
   
Note for display field 3:  
Oxygen sensor control behind catalytic converter is superior to oxygen sensor control before catalytic converter and is the 
primary control. It corrects slight changes in the mixture (i.e. enrichment or thinning) by holding the oxygen sensor control 
before catalytic converter at its higher or lower point for a specific time (duration). If this time is in the positive range (i.e. 50 
ms), mixture is shifted in the -enrich- direction. If this time is in the negative range (i.e. 50 ms), mixture is shifted in the -lean- 
Pa
ge 38 of 61 Ox
yg
en sensor control, checkin
g
11/22/2002 htt