Climate Control Systems 
Actlon 
Simultaneously hold FACE and FAN  and switch the ignition 
ON 
14.4 CLIMATE  CONTROL  SYSTEM TEST 
The control  panel has a self-diagnosis  feature, and is capable  of displaying  and deleting  stored fault codes. 
Climate  control is an  integrated  system, therefore 
it is recommended  that the Portable Diagnostic  Unit (PDU) is used 
for  fault  diagnosis.  The  fault codes  displayed  with the control  panel self-diagnosis feature  are not  as comprehensive 
as  those  of the  PDU.  The PDU  will display  the relevant fault  code, fault code  description and  information of the  system 
peripherals  at the  time  the fault  occurred. 
Resu It 
Control panel inputs  for clock,  start, data,  ignition  +ve and 
auxiliary  +ve are simultaneously examined  and cause indi- 
cator LED’s to illuminate  on satisfactory  line test. 
14.4.1 
System error  information is stored  in the  A/ C CM up to a maximum  of 5 faults. Should  a fault  occur  there will be an 
audible’beep‘and  the message ‘Er’will be displayed  on thecontrol  panel LCD display  for some 5 seconds after  ignition 
on.  Please  note that  this will happen only once in any ignition  switch cycle.  The  error source  may be accessed  by the 
following  procedure.  A  list and description  of all  accessible  fault codes  is provided  on the  following  page. 
Fault Code Extraction and  Deletion Procedure 
I Item Check LED 
Ignition  Defrost 
Auxiliary  Face 
Clock  Feet 
/ face 
Start  input  Foot 
Data  out  Screen 
/ foot 
Dimmer  override  Recirc. 
. Switch off the ignition. 
Press  and hold  the ‘Auto’  and ‘Fresh / Recirc.’  buttons  simultaneously,  and switch  on the  ignition. 
. All the  control  panel LED’s and all LCD  segments  will flash  on and off. Any  function  LED indicator  which does not 
flash  on / off suggests a fault condition  within that area  of the  panel  or, with  the LED. 
Any  LCD  element  which fails to flash  on 
/ off indicates  a fault  within  the panel  or display  element. 
. Press ‘Auto’. 
. Press ‘Face‘  to scroll  through  a maximum  of 5 fault codes. 
W 
Thecontrol  panel display  will flash  repeatedly  indicating a list oftwo digit  numbers (refer  to following  page for code 
analysis). 
. If, when  a code  is displayed,  an accompanying  ‘beep‘ is emitted,  the indicated  fault is current and therefore still pres- ent  within the  system.  A  code displayed  without an accompanying  ‘beep’ indicates a  fault had previously occurred 
but  is not  present  within the system. 
It is advisable  to check  all areas  indicated with cleared  fault codes.  Such faults may re-occur if intermittent 
problems  are present in the system. 
If 
’0‘ is 
displayed,  there are no stored  fault codes,  wait 30 seconds  to allow  system  self-test. 
W: 
. To delete  stored  and cleared  fault codes  simultaneously  press ‘HRW and ‘FACE‘  switches. 
. After investigating  and correcting  all stored  faults,  press  the ‘Push Off button  to restore  normal operation with de- 
fault panel  settings, ie AUTO  at 24OC. 
Condition 
IGN input  at 12V, check  LED is illuminated 
AUX 
input at 12V, check  LED is illuminated 
Clock 
input normal,  check  LED is illuminated 
Start  input  normal,  check LED is illuminated 
Data  out input  normal,  check  LED is illuminated 
Dimmer  override  input 
ON, check LED is illuminated 
14.4.2 Panel  Communications Check 
Panel communications  check verifies  the inputs  and outputs  from the control  panel to the  A/ CCM. 
To  exit  the panel  communications  check mode press the system  ON button. 
Issue 1 August 1994 10 X300 EDM  
Climate Control Systems 
14.6 ACTUATOR CHECK 
The system self test procedure drives all the actuator motors,  to checktheir  operation. If an actuator is  operating incor- rectly or operating outside  of its  limits  then a fault code  will be present. 
Before  commencing  with the actuator  check procedure,  ensure  the car is operating  under normal conditions. 
Actuator  Check Procedure 
. Switch off the ignition. 
. Press and hold  the 'Auto'  and 'Fresh / Recirc.'  buttons  simultaneously,  and run the  engine. 
All the control panel LED's and all LCD segments  will flash  on and  off.  Any function LED indicator which  does not 
. Any LCD element  which fails  to flash  on / off indicates a fault within  the display  element or  panel. 
. Press 'Auto'. 
. Press 'Fresh / Recirc.'  button to instigate  actuator check mode. 
. Use 'Face'  to cycle  through  actuator  mode conditions 20 to 27, as detailed  in the  table  below. 
flash 
on 
/ off suggests a fault condition  within that area of the panel or, with  the LED. 
Press  the 'Push Off button  to restore  normal operation  with default  panel settings, ie AUTO at 24OC. 
1ynfe: * The water valve  operates on a 6 second pulse, ie 3 seconds ON, 3 seconds  OFF. 
Issue 1 August 1994 12 X300 VSM