(b) Apply seal packing to the sealing groove of the waterinlet housing as shown in the illustration.
Seal packing: Part No. 08826±00100 or equivalent
w Install a nozzle that has been cut to a 2±3 mm
(0.08±0.12 in.) opening.
HINT: Avoid applying an excessive amount to the surface. w Parts must be assembled within 5 minutes of
application. Otherwise the material must be
removed and reapplied.
w Immediately remove nozzle from the tube and
reinstall cap.
(c) Install a new O±ring to the water inlet housing.
(d) Apply soapy water to the O±ring.
(e) Push the water inlet housing end into water pump hole.
(f) Install the water inlet and inlet housing assembly with the two bolts. alternately tighten the bolts.
Torque: 18 N Vm (185 kgf Vcm, 13 ft Vlbf)
HINT: Use bolts 25 mm (0.98 in.) in length.
(g) Connect the water by±pass hose to the water inlet
housing.
3. INSTALL RH IGNITION COIL (a) Install the ignition coil with the two bolts.
(b) Connect the ignition coil connector.
4. INSTALL TIMING BELT (See steps 4 to 43 on pages EM±47 to 57)
±
COOLIING SYSTEM Water PumpCO±11
WhereEverybodyKnowsYourName
Page 1296 of 4087

12. REMOVE SPOOL VALVE(a) Using a 10 mm hexagon wrench, remove the end plugand following parts:
(1) Spool valve
(2) Compression spring
(3) Spool sleeve
(b) Remove the O±ring from the end plug.
INSPECTION OF HYDRAULIC PUMP
1. CLEAN DISASSEMBLED PARTS Using a cleaner and compressed air, clean the disassembled
parts.
CAUTION: Thoroughly clean the oil passages of the rear
housing. Oil passage A includes a filter which should be
cleaned carefully.
2. INSPECT SPOOL VALVE (a) Coat the spool valve with PS fluid, and check that it falls
smoothly into the spool sleeve by its own weight.
(b) Check the spool valve for leakage. Close one of the holes and apply compressed air
392±490 kPa (4±5 kgf/cm2, 57±71 psi) into the opposite
side, check that air does not come out of the end hole.
If it doesn't, replace the spool valve and sleeve as a set.
3. INSPECT SPOOL COMPRESSION SPRING Using a vernier calipers, measure the free length of the com-
pression spring.
Free length: 45.8 mm (1.803 in.)
If the free length is not as specified, replace the compression
spring.
CO±34
±
COOLIING SYSTEM Electronically Controlled Hydraulic
Cooling Fan (Hydraulic Pump)
WhereEverybodyKnowsYourName
Page 1304 of 4087

INSTALLATION OF HYDRAULIC PUMP
(See Components on page CO±26)
1. INSTALL HYDRAULIC PUMP (a) Install the hydraulic pump, solenoid valve connector
clamp and engine speed sensor wire clamp with the two
bolts and two nuts.
Torque:
12 mm head 16 N Vm (160 kgf Vcm, 12 ft Vlbf)
14 mm head 20 N Vm (310 kgf Vcm, 22 ft Vlbf)
HINT: Each bolt length is indicated in the illustration.
Bolt length:
A 106 mm (4.17 in.) for 12 mm head
B 114 mm (4.49 in.) for 14 mm head
(b) Connect the solenoid valve connector.
2. CONNECT PRESSURE AND SUCTION HOSES TO HYDRAULIC PUMP
(a) Connect the pressure hose with new gasket and unionbolt.
Torque: 64 N Vm (650 kgf Vcm, 47 ft Vlbf)
(b) Connect suction hose.
3. INSTALL RH NO.2 TIMING BELT COVER
(a) Install the four gaskets to the timing belt cover.
(b) Install the connector grommet to the timing belt cover.
(c) Install the timing belt cover with the five bolts.
Torque: 16 N Vm (160 kgf Vcm, 12 ft Vlbf)
HINT (12 mm head bolt): Use bolts 106 mm (4.17 in.) in
length.
(d) Install the wire clamp to the timing belt cover.
(e) Install the cam position sensor wire to the wire clamp on
the timing belt cover.
(f) Install the cam position sensor connector to the ignition coil bracket.
4. INSTALL LH NO.2 TIMING BELT COVER (a) Install the two gaskets to the timing belt cover.
(b) Run the cam po sition sensor wire through the timing belt
cover hole.
(c) Install the timing belt cover and connector bracket with the three bolts.
(d) Connect the cam position sensor connector.
(e) In sta ll th e ca m po sitio n se n so r c onnector to the
connector bracket.
(f) Install the cam position sensor wire to the wire clamp on
the timing belt cover.
(g) Install the connector grommet to the timing belt cover.
CO±42
±
COOLIING SYSTEM Electronically Controlled Hydraulic Cooling Fan
(Hydraulic Pump)
WhereEverybodyKnowsYourName
Page 1370 of 4087

Compression at 250 rpm STD 1,226 kPa (12.5 kgf/cm2, 178 psi) or
more
pressureLimit 981 kPa (10.0 kgf/cm2, 142 psi) Difference of pressure between each cylinder 98 kPa (1.0 kgf/cm2, 14 psi) or less
Timing belt
tensionerProtrusion from housing end10.5±11.5 mm (0.413±0.453 in.)
Cylinder head Warpage Limit 0.10 mm (0.039 in.)
Valve seat
Refacing angle 30
5, 45 5, 75 5
Contacting angle 455
Contacting width 1.0±1.4 mm (0.039±0.055 in.)
Cylinder head bolt thread inside diameter STD 9.770±9.960 mm (0.3846±0.3921 in.)
Limit 9.60 mm (0.3780 in.)
Valve guideInside diameter6.010±6.030 mm (0.2366±0.2374 in.)
bushing Outside diameter (for repair part) STD 11.048±11.059 mm (0.4350±0.4354
in.)
O/S 0.05 11.098±11.109 mm (0.4369±0.4374 in.) ValveValve overall lengthSTD (Intake)94.95 mm (3.7382 in.) (Exhaust) 96.90 mm (3.8150 in.) Limit (Intake) 94.45 mm (3.7185 in.) (Exhaust) 96.40 mm (3.7953 in.)
Vale face angle 44.55
Stem diameter Intake 5.970±5.985 mm (0.2350±0.2356 in.)
Exhaust 5.965±5.980 mm (0.2348±0.2354 in.)
Stem oil clearance STD (Intake) 0.025±0.060 mm (0.0010±0.0024 in.)
(Exhaust) 0.030±0.065 mm (0.0012±0.0026 in.)
Limit (Intake) 0.08 mm (0.0031 in.)
(Exhaust) 0.10 mm (0.0039 in.)
Margin thickness STD 1.0 mm (0.039 in.)
Limit 0.5 mm (0.020 in.)
Valve spring Squareness Limit 2.0 mm (0.079 in.)
Free length 43.6 mm (1.717 in.)
Installed tension at 32.9 mm (1.295 in.) 186±206 N (19.0±21.0 kgf, 41.9±46.3
lbf)
Valve lifter
Lifter diameter
30.966±30.976 mm (1.2191±2.2195
in.)
Lifter bore diameter
31.000±31.016 mm (1.2205±1.2211
in.)
Oil clearance STD 0.024±0.050 mm (0.0009±0.0020 in.)
Limit 0.07 mm (0.0028 in.)
EG±206±
1UZ ± FE ENGINE ENGINE MECHANICAL
WhereEverybodyKnowsYourName
Page 1406 of 4087

31. RECONNECT FUEL INLET HOSE TO LH DELIVERY PIPE
(a) Temporarily connect the fuel inlet hose to the delivery pipewith 2 new gaskets and pulsation damper.
(b) Using SST, tighten the pulsation damper.
SST 09631±22020
Torque:
39 NVm (400 kgf Vcm, 29 ft Vlbf)
33 N Vm (340 kgf Vcm, 24 ft Vlbf) for SST
HINT: Use a torque wrench with a fulcrum length of 30 cm
(11.81 in.).
32. RECONNECT FUEL RETURN HOSE TO FUEL RETURN PIPE
33. RECONNECT PCV HOSE TO LH CYLINDER HEAD
34. REINSTALL RH ENGINE WIRE COVER
(a) Fit portions A and B of the engine wire cover, matching them with the lower high±tension cord cover and No.3 timing belt
cover.
(b) Install the timing belt cover with the bolt.
35. REINSTALL LH ENGINE WIRE COVER
(a) Connect portions A and B of the engine wire cover to the wire
brackets.
(b) Set the VSV (for the fuel pressure) wire in original position.
(c) Fit portions C and D of the engine wire cover, matching them with the lower high±tension cord cover and No.3 timing belt
cover.
(d) Install the timing belt cover with the 2 bolts.
36. REINSTALL UPPER HIGH±TENSION CORD COVER
(a) Fit portion A of the upper high±tension cord cover matching the top of the lower high±tension cord cover.
EG±30
±
1UZ±FE ENGINE ENGINE MECHANICAL
WhereEverybodyKnowsYourName
Page 1437 of 4087

8. INSTALL HYDRAULIC PUMP
(a) Install the hydraulic pump, solenoid valve connector clampand crankshaft position sensor wire clamp with the 2 bolts
and 2 nuts.
Torque:
16 NVm (160 kgf Vcm, 12 ft Vlbf) for 12 mm head
30 N Vm (310 kgf Vcm, 22 ft Vlbf) for 14 mm head
HINT: Each bolt length is indicated in the illustration.
Bolt length:
106 mm (4.17 in.) for A of 12 mm head
114 mm (4.49 in.) for B of 14 mm head
(b) Connect the solenoid valve connector.
9. INSTALL CRANKSHAFT PULLEY
(a) Align the pulley set key with the key groove of the crankshaft pulley.
(b) Using SST and a hammer, tap in the crankshaft pulley. SST 09223±46011
(c) Using SST, install the pulley bolt. SST 09213±70010, 09330±00021
Torque: 245 N Vm (2,500 kgf Vcm, 181 ft Vlbf)
10. INSTALL RH CAMSHAFT TIMING PULLEY
(a) Align the camshaft knock pin with the knock pin groove of the
timing pulley, and slide on the timing pulley.
(b) Slide the timing pulley on the camshaft, facing the ªRº mark forward.
(c) Using SST, install the pulley bolt. SST 09278±54012
Torque: 108 N Vm (1,100 kgf Vcm, 80 ft Vlbf)
±
1UZ±FE ENGINE ENGINE MECHANICALEG±61
WhereEverybodyKnowsYourName
Page 1441 of 4087

19. INSTALL DRIVE BELT TENSIONERInstall the belt tensioner with the bolt and 2 nuts.
Torque: 16 N Vm (160 kgf Vcm, 12 ft Vlbf)
HINT: Use bolt 106 mm (4.18 in.) in length.
20. INSTALL GENERATOR
(a) Install the generator and transmission oil cooler pipe bracket with the bolt and nut.
Torque: 37 N Vm (380 kgf Vcm, 27 ft Vlbf)
(b) Connect the generator connector.
(c) Connect the generator wire with the nut and cap.
21. INSTALL RH DISTRIBUTOR HOUSING
Install the distributor housing with the 3 bolts.
Torque: 18 N Vm (185 kgf Vcm, 13 ft Vlbf)
HINT:
w The RH distributor housing is marked with ªRº.
w Each bolt length is indicated in the illustration.
Bolt length:
38 mm (1.50 in.) for A
96 mm (3.78 in.) for B
22. INSTALL LH DISTRIBUTOR HOUSING Install the distributor housing with the 3 bolts.
Torque: 18 N Vm (185 kgf Vcm, 13 ft Vlbf)
HINT:
w The LH distributor housing is marked with ªLº.
w Each bolt length is indicated in the illustration.
Bolt length:
38 mm (1.50 in.) for A
80 mm (3.15 in.) for B
23. INSTALL DISTRIBUTOR ROTORS
(a) Align the protrusion of the distributor rotor with the groove the
camshaft timing pulley.
(b) Install the distributor rotor with the 2 bolts. Install the 2 distributor rotors.
Torque: 3.8 N Vm (39 kgf Vcm, 34 in. Vlbf)
±
1UZ±FE ENGINE ENGINE MECHANICALEG±65
WhereEverybodyKnowsYourName
Page 1442 of 4087

24. INSTALL DISTRIBUTOR CAPSInstall the distributor cap with the 3 bolts. Install the 2 distribu-
tor caps.
Torque: 3.8 N Vm (39 kgf Vcm, 34 in. Vlbf)
25. INSTALL RH NO.2 TIMING BELT COVER
(a) Install the 4 gaskets to the timing belt cover.
(b) Install the wire grommet to the timing belt cover.
(c) Fit the timing belt cover, matching it with the hydraulic pump.
(d) Fit the timing belt cover holes, matching them with the 2
grommets on the distributor cap.
(e) Install the timing belt cover with the 5 bolts.
Torque:
18 NVm (185 kgf Vcm, 13 ft Vlbf) for 12 mm head
HINT (for 12 mm head): Use bolts 106 mm (4.17 in.) in length.
(f) Install the wire clamp to the timing belt cover.
(g) Install the camshaft position sensor connector to the ignition coil bracket.
26. INSTALL LH NO.2 TIMING BELT COVER
(a) Install the 2 gaskets to the timing belt cover.
(b) Run the camshaft position sensor wire through the timing belt
cover hole.
(c) Fit the timing belt cover, matching it with the hydraulic pump.
(d) Fit the timing belt cover holes, matching them with the 2 grommets on the distributor cap.
(e) Install the timing belt cover and connector bracket with the 3 bolts.
(f) Install the wire grommet to the timing belt cover.
(g) In sta ll th e ca msh a ft po sitio n se n so r c onnector to the
connector bracket.
EG±66
±
1UZ±FE ENGINE ENGINE MECHANICAL
WhereEverybodyKnowsYourName