AIR-CONDBTIONI G - Evaporator 24-43
EVAPORATOR
REMOVAL AND INSTALLATION
N24RA--
Pre-removal Operation
l
Discharge the refrigerant. (Refer to
P.24-36) Removal
steps ~~ 1. Liquid pipe connection
l + 2. Suction hose connection
3. Nut
4. Glove box
5. Main harness connector connection
6. Duct joint
7. Drain hose connection
8. Bolt
9. Evaporator
NOTE
(I) Reverse the removal procedures to reinstall.
(2) l
* : Refer to “Service Points of Installation”.
Nut
I Union
/
2OUO267
SERVICE POINTS OF REMOVAL Caution N24MAC If the hoses or pipes are disconnected, cap the hoses or pipes:
with a blank plug to prevent entry of dust, dirt, and water.
SERVICE POINTS OF INSTALLATION N24AOAE 2. APPLICATION OF COMPRESSOR OIL TO SUCTION
HOSE/l. LIQUID PIPE
Apply specified compressor oil to portions indicated
before installing the liquid pipe (C) and suction flexible
hose.
Specified oil : DENS0 oil 6
!vision
24-46
COMPRESSOR
AIR-CONDITIONING - Compressor
DISASSEMBLY AND REASSEMBLY N24TE-
15-h Nm
11-13 ftlbs 16
a 0
I
26-26 Nm
16-20 ftlbs. Magnetic clutch disassembly steps
1. Nut
~~ Adjustment of clutch clearance
2. Clutch hub
3. Shims
4.
Snap ring
4* 5. Rotor assembly
6.
Snap ring
7.
Ground terminal
l + 8. Clutch coil
l5Dl
2QY947 Compressor front housing and service valve disas-
sembly steps
9. Oil drain guide
10.
Woodruff key
Il. Through bolt
** Refilling of compressor oil
12. Front housing
o+
13. Shaft seal
04 14.
Shaft plate
15.
Gasket
16. O-ring
NOTE
(1) Reverse the disassembly procedures to reassemble.
(2) +e : Refer to “Service Points of Disassembly”.
(3) e+ : Refer to “Service Points of Reassembly”.
(4)
q : Non-reusable parts 1 STB Revision