4A IDLE-UP CONTROL SYSTEM
IDLE-UP SOLENOID VALVE
FE and F8 (General, ECE, Hong Kong, and Singapore)
Water thermo switch Fan speed control switch Headlights _
Rear defroster
A/C
Engine1
control -
unit
Richer air bleed
Richer jet
/ '
Inhibitor switch
Water thermo switch Fan speed _ control switch Headlights -
Rear defroster —
A/C
Engine
control
unit
Idle-up solenoid valve
Adjust screw
Secondary
throttle valve
From secondary main jet
76G04A-151
The idle-up solenoid valve opens when the following conditions are met.
Condition
When inhibitor switch is OFF (ATX—other than "P" and "N" range) and any of the following:
• Engine coolant temperature less than 72°C (162°F).
• A/C operated.
• Fan speed control switch 3rd or 4th position.
• Headlights turned on.
• Rear defroster turned on.
4A—76
ALTERNATOR 5
Warning
Disconnect the nagative battery terminal when disconnect or reconnect B terminal.
TEST 1
1. Disconnect the alternator connector (2-pin).
2. Connect the SST.
4. Connect the red clip of the adapter harness to the battery
(
+
),
and check that the red
lamp and green lamp illuminate.
5. Start the engine and check that both lamps go off.
86U05X-010
TEST 2
1. Connect an ammeter (75A min.) between the wire and the B terminal.
2. Turn all headlights and accessories on, and depress the brake pedal.
3. Start the engine and check that output current is 70A (RF-CX: 75A) or more at
2,500—3,000 rpm of the engine speed.
Caution
Do not ground the B terminal.
76G05X-029
B terminal
5-25