Charge System
ItemServicing data
Input power 110 - 240 V AC
Rated frequency 60 Hz
Maximum rated electrical current In normal charge
32A AC
Maximum power consumption 7.2 kVA (normal charge)
Electrical leakage detection current
for control box including genuine
charge cable 5 mA
EV charge mode/Connection type Normal charge: Mode 2, Mode 3/TYPE1
Installation requirements
(information on protection against
short-circuit current and equipment
protection) Applicable laws and regulations, and standards must be followed
for protection measures against over-current and over-voltage.
Always make sure to install a ppropriate over-current protection
devices to the wiring of houses and buildings.
IP level IP44: When charge connector is connected to charge inlet
IP67 : Charging Cable
Operating temperature On Board Charger
Ambient temperature : -30 °C ( -22 °F) to 85 °C (185 °F)
coolant temperature : -30 °C ( -22 °F) to 70 °C (158 °F)
Charging Cable
Ambient temperature : -30 °C ( -22 °F) to 55 °C (131 °F)
Storage temperature On Board Charger
Ambient temperature : -40 °C ( -40 °F) to 85 °C (185 °F)
coolant temperature : -40 °C ( -40 °F) to 85 °C (185 °F)
Charging Cable
Ambient temperature : -40 °C ( -40 °F) to 80 °C (176 °F)
Applicable standards On Board Charger
EN/IEC 61851-1, EN/IEC 61851-21, EN/IEC 61851-23, UL 2202
Charging Cable
NFPA 70, NFPA 79, SAE-J 1772, UL 62, UL 817, UL 2231-1, UL
2231-2, UL 2251, UL 2594, CSA C22.2 No.280-16
Adapters Do not use an adapter with the plug and connector of the charg-
ing cable.
Do not use an extension cable.
Specifications/Customer Information and Reporting Safety Defects
Ve h i c l e Specification
10-63