Charge connector
The charge connector is used for
connecting to the normal charge port.
When the charge connector is
connected to the normal charge port,
a vehicle system locks the charge
connector.
When the charge connector is locked
by the vehicle system, it unlocks when
the driver’s door is unlocked.
If the charge connector locked by the
vehicle system is not unlocked even
though the driver’s door is unlocked,
consult an Authorized Mazda Dealer.
The conditions for locking the system
on the vehicle side can be changed.
For the procedure to change the
conditions, refer to Charging Settings
on page 3-21.
Control box
The control box indicates the charge
status by turning on/flashing the
indicator light.
For the indicator light illumination/
fl ash pattern, refer to the instruction
manual accompanying the charge
cable.
Charge plug
The charge plug is the part for
connecting to the power supply.
Charge port
The charge port refers to the area
where the charge connector is
connected.
The component parts of the charge
port are as follows.
1. Charge indicator
2. Normal charge port
3. Normal charge port cap
4. Charge lid
5. Quick charge port cap
6. Quick charge port
Charge indicator
The charging indicator indicates the
charging status by turning on/flashing
the light.
For the charging indicator
illumination/ flash pattern, refer to
Checking Charging Status on page
3-18.
Normal charge port
The normal charge port is the part to
which the connector of the charge
cable is connected. This is used for
normal charging.
Charge lid
The charge lid is locked/unlocked in
conjunction with the door locking/
unlocking mechanism.
When unlocking the driver’s door, the
charge lid is unlocked. When locking
the driver’s door, the charge lid is
locked.
However, if the driver’s door is
unlocked using the auxiliary key, the
charge lid is not unlocked.
Before Driving
Electric Vehicles
3-13
MX -30_8JD4-EA -21G_Edition2_new 2021-5-18 14:38:07
NOTE
When the driver's door is locked using
any of the following functions, the
charge lid is also locked at the same
time.
Vehicle speed sensing auto door lock
function
Auto re-lock function
Quick charge port
The quick charge port is the part to
which the connector of the quick
charger is connected. This is used for
quick charging.
Battery heater
The battery heater is designed to
maintain the appropriate high voltage
battery temperature.
Because the driving performance and
the charging performance decrease if
the high voltage battery temperature
decreases, decreases in their
performance are reduced by
maintaining the appropriate high
voltage battery temperature using the
battery heater.
When the high voltage battery
temperature decreases signi ficantly
while parking or charging , the battery
heater operates. When the
temperature increases to the speci fied
value, the heater turns o ff.
However, when the high voltage
battery level is low, the battery heater
does not operate.
NOTE
Because the electrical power of the
high voltage battery is used by the
battery heater, we recommend that
the charge connector is left
connected to the vehicle when
parked in a location where charging
is available.
If the vehicle is not used for a long
period of time, we recommend that
the battery heater is turned o ff using
[Settings] in Mazda Connect.
When the battery heater operates,
the charging time could take longer.
Battery cooling
If the high voltage battery temperature
reaches 40 ℃ (104 ℉) or higher after
driving the vehicle, it is possible to cool
the high voltage battery while the
vehicle is parked for maintaining a long
high voltage battery life.
If the Excessive Battery Temperature
noti fication is displayed on the center
display after completing a trip, select
Start to operate the battery cooling.
NOTE
Because the electrical power of the
high voltage battery is used by the
battery cooling , we recommend that
the charge connector is connected to
the vehicle while the battery cooling is
operating , when parked in a location
where charging is available.
▼ Charging
Charging type
There are two methods of charging the
high voltage battery, normal charging
and quick charging.
We recommend that you use normal
charging as the preferred charging
method as this will help to keep the
high voltage battery in optimal
condition and maintain a long battery
life.
The exact charging time depends on
various conditions at the time of
charging , such as the type of charger,
battery condition, ch
arging patterns, as
well as the battery temperature and
ambient temperature. In cold weather
Before Driving
Electric Vehicles
3-14
MX -30_8JD4-EA -21G_Edition2_new 2021-5-18 14:38:07
5. Connect the charge plug to theoutlet.
6. Connect the charge connector to the normal charge port. Charging
starts after connection is
completed.
Make sure to lock all the doors
before leaving the vehicle while
charging.
NOTE
When the charging timer is set,
charging does not start even if the
charge connector is connected.
When you prefer to start charging
immediately, use the charging
timer cancellation function.
1. Normal charge port
7. When charging is finished, remove
the charge connector.
8. Close the normal charge port cap.
9. Close the charge lid.
10.Remove the charge plug from the power supply.
Make sure to lock all the doors before
leaving the vehicle.
How to perform quick charging
1. Shift the selector lever to the P
position.
2. Switch the power switch OFF.
3. Press the location shown in the figure to open the charge lid.
4. Open the quick charge port capand normal charge port cap.
1. Quick charge port cap
2. Normal charge port cap
5. Connect the charge connector of the quick charger to the quick
charge port.
1. Quick charge port
6. Operate the quick charger to start charging.
Before Driving
Electric Vehicles
3-16
MX -30_8JD4-EA -21G_Edition2_new 2021-5-18 14:38:07
CAUTION
When operating a quick charger,
always use the charger according to
its instructions. If the quick charger
is operated incorrectly, the quick
charger or vehicle could be
damaged.
Make sure to lock all the doors
before leaving the vehicle while
charging.
7. When charging is finished, remove
the charge connector.
8. Close the quick charge port cap.
9. Close the charge lid.
Make sure to lock all the doors before
leaving the vehicle.
Before Driving
Electric Vehicles
3-17
MX -30_8JD4-EA -21G_Edition2_new 2021-5-18 14:38:07
Powe r s wi tc h O F F
1. High voltage battery indication
2. Charging completion time
Powe r s wi tc h O N
1. High voltage battery indication
2. Charging completion time
IndicationContent
— Preparing to Charge Displays while the charging timer is being canceled
and when the charging connector is connected.
— Charging Scheduled Displays while in charging timer mode and when the
charging connector is connected.
Charging
Displays during charging.
Charging Complete Displays when charging is completed.
Charging Error. Shift Selector Lev-
er Not in ParkDisplays when charging is started with the selector
lever in a position other than P.
Charging Interrupted. See Own-
er's Manual for Details Displays when charging is interrupted.
Charging Error. Have the Vehicle
Inspected Displays when charging is not possible due to a
charging system problem.
NOTE
When charging is started, the charging st
atus screen is displayed for a while. The
charging status screen turns off after a certain period of time passes or the doors or
liftgate is locked.
The screen is displayed again when the doors or liftgate is unlocked.
Before Driving
Electric Vehicles
3-19
MX -30_8JD4-EA -21G_Edition2_new 2021-5-18 14:38:07
▼Convenient Functions
Timer Charging
Timer charging is a function which
charges the battery automatically
according to a preset time.
You can charge the battery using this
function during time periods when
electricity rates are low. In addition,
the maximum charge limit can be set
and changed.
For the setting method, refer to
Charging Settings on page 3-21.
Canceling the Charging Timer
You can cancel the charging timer
setting temporarily to start charging the
battery immediately.
For the setting method, refer to
Charging Settings on page 3-21.
Climate Control Timer
The climate control timer is a function
which operates the cooling or heating
system automatically according to a
preset time.
The power consumption of the air
conditioner after starting to drive the
vehicle is reduced by operating the air
conditioner and providing a
comfortable temperature in the cabin
before driving.
For the setting method, refer to Turning
On the Climate Control System Using
the Timer (Climate Control Timer) on
page 5-12.
Charge Connector Lock
The charge connector lock is a function
which locks the charging connector
connected to the vehicle so that it
cannot be pulled out.
You can also select the lock conditions
for the charging connector according
to locations and situations.
For the setting method, refer to
Charging Settings on page 3-21.
Locked When Connected
The charging connector is locked at
the same time the charging
connector is connected. The
charging connector is unlocked for 1
minute after the driver’s door is
unlocked.
Select Locked When Connected
when charging in the following
locations/situations.
Outdoor parking lotCharging using your charging cable
at a charging facility
Locked When Charging
The charging connector is locked
only while charging. The charging
connector is unlocked when the
charging is
finished. In addition, the
charging connector is unlocked for 1
minute after the driver’s door is
unlocked, even while charging.
Select Locked When Charging when
leaving the vehicle while charging at
a public charging station where
people are waiting to charge their
vehicles.
O ff
The charging connector is not
locked.
Select O ff when charging in the
following locations/situations.
Indoor parking lot with a shutter
Before Driving
Electric Vehicles
3-20
MX -30_8JD4-EA -21G_Edition2_new 2021-5-18 14:38:07
Use of the charge connector lock is
prohibited at a public charging
station.
Functions using a Smartphone
You can check the remaining high
voltage battery power, operate the
charging , and operate the air
conditioner remotely by using a
Smartphone.
Please refer to local Mazda website for
more Connected Service information.
▼ Charging Settings
How to set up the charging
1. Select Settings from the home
screen on Mazda Connect.
2. Select EV Settings from the setting
screen.
3. Select the setting item you want to change from the displayed content.
Charge When Connected
Cancels charging schedule to allow im-
mediate charging.
Available setting changes
Enable, Disable
NOTE
The charging timer can also be
canceled on the screen displayed on
the center display when the power
switch is switched OFF.
When the charging is completed
using the Charge When Connected
setting , the charging timer schedule
is restored.
Charging Schedule
Selects desired vehicle charging days
and times.
Function Available setting changes
1 ----
Enable, Disa-ble
*1Edit, Delete*2
2 ----
3 ----
4 ----
5 ----
6 ----
7 ----
*1 If a list selected using the cursor has beenset, the item can be Enable or Disable.
*2 Settings can be Edit/Delete by sliding a listselected using the cursor to the right.
NOTE
The charging timer does not work
immediately after the lead-acid
battery is removed or installed, or
when no GPS signal has been
received. When charging without
receiving GPS, quick charging begins.
When GPS signals are received, the
charging timer becomes operational.
Before Driving
Electric Vehicles
3-21
MX-30_8JD4-EA -21G_Edition2_new 2021-5-18 14:38:07
Setting example (if settings below are
made at 13 : 00 hours)
FunctionAvailable setting
changes
Start Time 12 : 00
End Time 18 : 00
Repeat Once
Charge Limit According to Esti-
mated Range
Estimated Range 50 km
In this case, when the charge
connector is connected, charging
starts immediately for charging to
18 : 00 hours on the same day.
However, if a charging amount
allowing a 50 km trip is reached, the
charging is stopped even if it is
before the end time.
Setting example (if settings below are
made at 13 : 00 hours)
Function Available setting
changes
Start Time 1 : 00
End Time 8 : 00
Repeat Once
Charge Limit According to Bat-
tery Charge Level
Battery Charge Level 100 %
In this case, charging is done from
the next day at 1 : 00 hours to 8 : 00
hours. However, if the Battery
Charge Level reaches 100% is
reached, the charging is stopped
even if it is before the End Time.
Charge Limit for AC Charging
Sets the charge limit when using an AC
charger.
Available setting changes
100% ― 10% (10 levels)
NOTE
For normal charge, set the maximum
charge limit of the high voltage battery.
Set the Battery Charge Level of the
charging timer for each charging timer
setting.
Charge Limit for DC Fast Charging
Sets the charge limit when using a DC
Fast charger.
Available setting changes
100% ― 10% (10 levels)
Charge Connector Lock
Con figures when the charge connector
is locked.
Available setting changes
Locked When Charging
Unlocks connector when charging is complete
or vehicle is unlocked.
Locked When Connected
Unlocks connector only when vehicle is un-
locked.
Before Driving
Electric Vehicles
3-23
MX -30_8JD4-EA -21G_Edition2_new 2021-5-18 14:38:07