Page 31 of 88 Report No. : 60404489 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
h) Protective conductor current exceeding ES2 limits N/A
i) Graphic symbols used on equipment N/A
j) Permanently connected equipment not provided
with al l - pole mains switch N/A
k) Replaceable components or modules providing
safeguard function N/A
l) Equipment containing insulating liquid N/A
m ) Installation instructions for outdoor equipment N/A
F.5
Instructional safeguards N/A
G COMPONENTS
N/A
G.1 Switches
N/A
G.1.1 General No such switches are used as
disconnect devices N/A
G.1.2 Ratings, endurance, spacing, maximum load N/A
G.1.3 Test method and compliance N/A
G.2 Relays
N/A
G.2.1 Requirements No such relays are used as
disconnect de vices N/A
G.2.2 Overload test N/A
G.2.3 Relay controlling connectors supplying power to
other equipment N/A
G.2.4 Test method and compliance N/A
G.3 Protective devices
N/A
G.3.1 Thermal cut - offs No thermal cut - offs N/A
Thermal cut - outs separatel y approved according to
IEC 60730 with conditions indicated in a) & b) N/A
Thermal cut - outs tested as part of the equipment as
indicated in c) N/A
G.3.1.2 Test method and compliance N/A
G.3.2 Thermal links No thermal links N/A
G.3.2.1 a) Thermal l inks tested separately according to IEC
60691 with specifics N/A
b) Thermal links tested as part of the equipment N/A
G.3.2.2 Test method and compliance N/A
G.3.3 PTC thermistors No PTC thermistors N/A
G.3.4 Overcurrent protection devices N/A
Page 32 of 88 Report No. : 60404489 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
G. 3.5 Safeguards components not mentioned in G.3.1 to
G.3.4 No such components N/A
G.3.5.1 Non - resettable devices suitably rated and marking
provided N/A
G.3.5.2 Single faults conditions ................................ .......... : N/A
G.4 Connectors
N/A
G.4.1 Spacings N/A
G.4.2 Mains connect or configuration .............................. : N/A
G.4.3 Plug is shaped that insertion into mains socket -
outlets or appliance coupler is unlikely N/A
G.5 Wound components
N/A
G.5.1 Wire insulation in wound components N/A
G.5.1.2 Protection against mechanical stress N/A
G.5.2 Endurance test N/A
G.5.2.1 General test requirements N/A
G.5.2.2 Heat run test N/A
Test time (days per cycle) ................................ ..... :
Test temperature ( C) ................................ ............ :
G.5.2.3 Wound components supplied from the mains N/A
G.5.2.4 No insulation breakdown N/A
G.5.3 Tra nsformers No transformers is used N/A
G.5.3.1 Compliance method ................................ ............... : N/A
Position ................................ ................................ .. : N/A
Method of protection ................................ .............. : N/A
G.5.3.2 Insulation N/A
Protection from displacement of windings ............. :
G.5.3.3 Transformer overload tests N/A
G.5.3.3.1 Test condit ions N/A
G.5.3.3.2 Winding temperatures N/A
G.5.3.3.3 Winding temperatures - alternative test method N/A
G.5.3.4 Transformers using FIW N/A
G.5.3.4.1 General N/A
FIW wire nominal diameter ................................ .... :
G.5.3.4.2 Transformers with basic insulation only N/A
Page 34 of 88 Report No. : 60404489 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
G.7.3.2.1 Requirements N/A
Strain relief test force (N) ................................ ...... : N/A
G.7.3.2.2 Strain relief mechanism failure N/A
G.7.3.2.3 Cord sheath or jacket position, distance (mm) ...... : N/A
G.7.3.2.4 Strain relief and cord anchorage material N/A
G.7.4 Cord Entry N/A
G.7.5 Non - detachable cord bend protection N/A
G.7.5.1 Requirements N/A
G.7.5.2 Test method and compliance N/A
Overall diameter or minor overall dimension, D
(mm) ................................ ................................ ...... :
Radius of curvature after test (mm) ....................... :
G.7.6 Supply wiring space N/A
G.7.6.1 General requirements N/A
G.7.6.2 Stranded wire N/A
G.7.6.2.1 Requirements N/A
G.7.6.2.2 Test with 8 mm strand N/A
G.8 Varistors
N/A
G.8.1 General requirements N/A
G.8.2 Safeguards against fire N/A
G.8.2.1 General N/A
G.8 .2.2 Varistor overload test N/A
G.8.2.3 Temporary overvoltage test N/A
G.9 Integrated circuit (IC) current limiters
N/A
G.9.1 Requirements N/A
IC limiter output current (max. 5A) ........................ :
Manufacturers’ defined drift ................................ .. :
G.9.2 Test Program N/A
G .9.3 Compliance N/A
G.10 Resistors
N/A
G.10.1 General N/A
G.10.2 Conditioning N/A
G.10.3 Resistor test N/A
Page 38 of 88 Report No. : 60404489 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
Instructional safeguard ................................ .......... : N/A
M EQUIPMENT CONTAINING BATTERIES AND THEIR PROTECTION CIRCUITS
N/A
M.1 General re quirements
N/A
M.2 Safety of batteries and their cells
N/A
M.2.1 Batteries and their cells comply with relevant IEC
standards ................................ ............................... : Batteries is not provided N/A
M.3 Protection circuits for batteries provided within
the equipment N/A
M.3.1 Requirements N/A
M.3.2 Test method N/A
Overcharging of a rechargeable battery N/A
Excessive discharging N/A
Unintentional charging of a non - rechargeable
battery N/A
Reverse charging of a rechargeable battery N/A
M.3.3 Compliance N/A
M.4 Additional safe guards for equipment containing a portable secondary lithium
battery N/A
M.4.1 General N/A
M.4.2 Charging safeguards N/A
M.4.2.1 Requirements N/A
M.4.2.2 Compliance ................................ ............................ : N/A
M.4.3 Fire enclosure ................................ ........................ : N/A
M.4.4 Drop test of equipment containing a secon dary
lithium battery N/A
M.4.4.2 Preparation and procedure for the drop test N/A
M.4.4.3 Drop, Voltage on reference and dropped batteries
(V); voltage difference during 24 h period (%): .... : N/A
M.4.4.4 Check of the charge/discharge function N/A
M.4. 4.5 Charge / discharge cycle test N/A
M.4.4.6 Compliance N/A
M.5 Risk of burn due to short - circuit during carrying
N/A
M.5.1 Requirement N/A
M.5.2 Test method and compliance N/A
M.6 Safeguards against short - circuits
N/A
Page 39 of 88 Report No. : 60404489 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
M.6.1 External and interna l faults N/A
M.6.2 Compliance N/A
M.7 Risk of explosion from lead acid and NiCd batteries
N/A
M.7.1 Ventilation preventing explosive gas concentration N/A
Calculated hydrogen generation rate .................... : N/A
M.7.2 Test method and compliance N/A
Minimum a ir flow rate, Q (m 3
/h) ............................. :
N/A
M.7.3 Ventilation tests N/A
M.7.3.1 General N/A
M.7.3.2 Ventilation test – alternative 1 N/A
Hydrogen gas concentration (%) ........................... : N/A
M.7.3.3 Ventilation test – alternative 2 N/A
Obtained hydrogen generation rate ....................... : N /A
M.7.3.4 Ventilation test – alternative 3 N/A
Hydrogen gas concentration (%) ........................... : N/A
M.7.4 Marking ................................ ................................ .. : N/A
M.8 Protection against internal ignition from external spark sources of batteries
with aqueous electrolyte N/A
M.8.1 General N/A
M.8.2 Test method N/A
M.8.2.1 General N/A
M.8.2.2 Estimation of hypothetical volume V
Z (m 3
/s) ......... :
M.8.2.3 Correction factors ................................ .................. :
M.8.2.4 Calculation of distance d (mm) ............................. :
M.9 Preventing electrolyte spillage
N/A
M.9.1 Protection from electrolyte spillage N/A
M.9.2 Tray for preventing electrolyte spillage N/A
M.10
Instructions to prevent reasonably foreseeable
misuse N/A
Instructional safeguard ................................ .......... : N/A
N ELECTROCHEMICAL POTENTIALS
N/A
Material (s) used ................................ ..................... :
Page 42 of 88 Report No. : 60404489 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
Mounting of samples ................................ ............ :
Wall thickness (mm) ................................ .............. :
S.4 Flammability classification of materials
N/A
S.5 Flammability test for fire enclosures and fire barrier materials of equipment
where the steady state power exceeding 4 000 W N/A
Samples, material ................................ .................. :
Wall thickness (mm) ................................ .............. :
Conditioning ( C) ................................ ................... :
T MECHANICAL STRENGTH TESTS
P
T.1 General
P
T.2 Steady force test, 10 N ................................ ....... :
N/A
T.3 Steady force test, 30 N ................................ ....... :
N/A
T.4 Steady force test, 100 N ................................ ..... :
N/A
T.5 Steady for ce test, 250 N ................................ ..... :
N/A
T.6 Enclosure impact test
P
Fall test P
Swing test N/A
T.7 Drop test ................................ .............................. :
N/A
T.8 Stress relief test ................................ ................... :
(See appended table T.8) P
T.9 Glass Impact Test ................................ ................... :
N/A
T.10 Glass fragmentation test
N/A
Number of particles count ed ................................ .... : N/A
T.11 Test for telescoping or rod antennas
N/A
Torque value (Nm) ................................ ................ : N/A
U MECHANICAL STRENGTH OF CATHODE RAY TUBES (CRT) AND
PROTECTION AGAINST THE EFFECTS OF IMPLOSION N/A
U.1 General
N/A
Instructional safeguard :
No CRT provided within the
equipment N/A
U.2 Test method and compliance for non - intrinsically protected CRTs
N/A
U.3 Protective screen
N/A
V DETERMINATION OF ACCESSIBLE PARTS
N/A
V.1 Accessible parts of equipment
N/A
Page 43 of 88 Report No. : 60404489 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
V.1.1 General N/A
V.1.2 Surfaces and openings tested w ith jointed test
probes N/A
V.1.3 Openings tested with straight unjointed test probes N/A
V.1.4 Plugs, jacks, connectors tested with blunt probe N/A
V.1.5 Slot openings tested with wedge probe N/A
V.1.6 Terminals tested with rigid test wire N/A
V .2 Accessible part criterion
N/A
X ALTERNATIVE METHOD FOR DETERMINING CLEARANCES FOR INSULATION
IN CIRCUITS CONNECTED TO AN AC MAINS NOT EXCEEDING 420 V PEAK
(300 V RMS) N/A
Clearance ................................ ................................ .. : N/A
Y CONSTRUCTION REQUIREMENTS FOR OUTDOOR ENCLOSURES
N/A
Y.1 G eneral
N/A
Y.2 Resistance to UV radiation
N/A
Y.3 Resistance to corrosion
N/A
Y.3 Resistance to corrosion
N/A
Y.3.1 Metallic parts of outdoor enclosures are resistant to
effects of water - borne contaminants by ................ : N/A
Y.3.2 Test apparatus N/A
Y.3.3 Water – saturated sulphur dioxide atmosphere N/A
Y.3.4 Test procedure ................................ ....................... : N/A
Y.3.5 Compliance N/A
Y.4 Gaskets
N/A
Y.4.1 General N/A
Y.4.2 Gasket tests N/A
Y.4.3 Tensile strength and elongation tests N/A
Alternative test methods ................................ ........ : N/A
Y.4.4 Compression test N/A
Y.4.5 Oil resistance N/A
Y.4.6 Securing means N/A
Y.5 Protection of equipment within an outdoor enclosure
N/A
Y.5.1 General N/A
Y.5.2 Protection from moisture N/A
Page 44 of 88 Report No. : 60404489 001
IEC 62368 - 1
Clause Requirement + Test Result - Remark Verdict
TR F No. IEC62368_1 C
Relevant tests of IEC 60529 or Y.5.3 .................... : N/A
Y.5.3 Water sp ray test N/A
Y.5.4 Protection from plants and vermin N/A
Y.5.5 Protection from excessive dust N/A
Y.5.5.1 General N/A
Y.5.5.2 IP5X equipment N/A
Y.5.5.3 IP6X equipment N/A
Y.6 Mechanical strength of enclosures
N/A
Y.6.1 General N/A
Y.6.2 Im pact test ................................ ............................. : N/A