Page  14   of  90   Report No. :  60404487 001  
 
 
TR F No.  IEC62368_1 C    
  
ENERGY SOURCE DIAGRAM  
Optional . Manufacturers are to provide the energy sources diagram identify declared energy sources and 
identifying the demarcations are bet ween power sources. Recommend diagram be provided included in 
power supply and multipart systems.  
Insert diagram below. Example diagram designs  are; Block   diagrams; image(s) with layered data; mechanical 
drawings  
■   ES        ■   PS          ■   MS           ■   TS            ■   RS  
 
ES Classification:  
ES1: All parts .  
 
PS Classification:  
PS3:  Head   unit .  
PS2:  LCD module   and  Keyboard circuits .  
 
MS classification:  
MS1 :  There are no sharp edges  or   corners .   Equipment mass is under 7 kg .  
 
TS classification:  
TS1: All accessible  parts including monitor enclosure, screen surface and keyboard enclosure .  
 
RS classification:  
RS1:   Indicating lights and low power devices.   

   
 
Page  15   of  90   Report No. :  60404487 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  
4   GENERAL REQUIREMENTS  
P  
4.1.1   Acceptance of materials, components and 
subassemblies   (See appended table 4.1.2)   P  
4.1.2   Use of components  
The equipment is so designed 
and constructed that, under 
normal operating  conditions   
(see Clause B.2),  abnormal 
operating conditions  (see 
Clause B.3), and  single fault  
conditions  (see Clause B.4), 
safeguards  are provided to 
red uce the likelihood of injury 
or, in the case of fire, property 
damage   P  
4.1.3   Equipment design and construction  
  P  
4.1.4   Specified ambient temperature for outdoor use ( o
C)
  ................................ ................................ ....................   :   Not intended for outdoor use   N/A  
4.1.5   Constructions and components not specifi cally 
covered     N/A  
4.1.8   Liquids and liquid filled components (LFC)     N/A  
4.1.15   Markings and instructions   (See Annex F)   P  
4.4.3   Safeguard robustness      P  
4.4.3.1   General     P  
4.4.3.2   Steady force tests   Building - in equipment   N/A  
4.4.3.3   Drop tests   Buildi ng - in equipment   N/A  
4.4.3.4   Impact tests     P  
4.4.3.5   Internal accessible safeguard tests   No  Internal accessible 
safeguard   is used   N/A  
4.4.3.6   Glass impact tests   No glass in the equipment   N/A  
4.4.3.7   Glass fixation tests   No laminated glass used    N/A  
  Gl ass impact test (1J)     N/A  
  Push/pull test (10 N)     N/A  
4.4.3.8   Thermoplastic material tests     P  
4.4.3.9   Air comprising a safeguard     N/A  
4.4.3.10   Accessibility, glass, safeguard effectiveness     P  
4.4.4   Displacement of a safeguard by an insulating liquid   N o  insulating liquid   used   N/A  
4.4.5   Safety interlocks   No  Safety interlocks   N/A   

   
 
Page  30   of  90   Report No. :  60404487 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  B.3.7   Audio amplifier  abnormal operating conditions     P  
B.3.8   Safeguards functional during and after abnormal 
operating conditions   ................................ ..............   :   (See appended table B.3)   P  
B.4   Simulated single fault conditions
  P  
B.4.1   General     P  
B.4.2   Temperature controlling device     N/A  
B. 4.3   Blocked motor test   (See appended table B. 4 )   N/A  
B.4.4   Functional insulation     P  
B.4.4.1   Short circuit of clearances for functional insulation     P  
B.4.4.2   Short circuit of creepage distances for functional 
insulation     P  
B.4.4.3   Short circuit of functi onal insulation on coated 
printed boards     N/A  
B.4.5   Short - circuit and interruption of electrodes in tubes 
and semiconductors     P  
B.4.6   Short circuit or disconnection of passive 
components     P  
B.4.7   Continuous operation of components     N/A  
B.4.8   Compliance   during and after single fault conditions
  ................................ ................................ ...............   :   (See appended table B.4)   P  
B.4.9   Battery charging and discharging under single fault 
conditions   Battery is not provided   N/A  
C   UV RADIATION  
N/A  
C.1   Protection of materials in equipment from UV radiation  
N/A  
C. 1.2   Requirements      N/A  
C.1.3   Test method     N/A  
C.2   UV light conditioning test  
N/A  
C.2.1   Test apparatus   ................................ .......................   :     N/A  
C.2.2   Mounting of test samples     N/A  
C.2.3   Carbon - arc light - exposure  test     N/A  
C.2.4   Xenon - arc light - exposure  test     N/A  
D   TEST GENERATORS  
N/A  
D.1   Impulse test generators  
N/A  
D.2   Antenna interface test generator  
N/A  
D.3   Electronic pulse generator  
N/A   

   
 
Page  35   of  90   Report No. :  60404487 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  G.5.3.4.3   Transformers with double insulation or reinforced 
insulation   ................................ ...............................   :     N/A  
G.5.3.4.4   Transformers with FIW wound on metal or ferrite 
core     N/A  
G.5.3.4.5   Thermal cycling test and compliance     N/A  
G.5.3.4.6   Partial discharge test     N/A  
G.5.3.4.7   Routine test     N/A  
G.5.4   Motors   (See appended table 4.1.2)   N/A  
G.5.4.1   General requirements     N/A  
G.5.4.2   Motor overload test conditions     N/A  
G.5.4.3   Running overload test     N/A  
G.5.4.4.2   Locked - rotor overload test     N/A  
  Test duration (days)  ................................ ..............   :    
  
G.5.4.5   Running overload test for DC motors     N/A  
G.5.4.5.2   Tested in the unit      N/A  
G.5.4.5.3   Alternative method     N/A  
G.5.4.6   Locked - rotor overload test for DC motors      N/A  
G.5.4.6.2   Tested i n the unit     N/A  
  Maximum Temperature    ................................ ........   :     (See appended table B.3, B.4)   N/A  
G.5.4.6.3   Alternative method     N/A  
G.5.4.7   Motors with capacitors     N/A  
G.5.4.8   Three - phase motors     N/A  
G.5.4.9   Series motors     N/A  
  Operating voltage    ................................ .................   :    
  
G.6   Wire  Insulation  
N/A  
G.6.1   General     N/A  
G.6.2   Enamelled winding wire insulation     N/A  
G.7   Mains supply cords  
N/A  
G.7.1   General requirements     N/A  
  Type   ................................ ................................ .......   :    
  
G.7.2   Cross sectional area (mm 2
  or AWG)   .....................   :     N/A  
G.7.3   Cord anchorages and strain relief for non -
detac hable power supply cords     N/A  
G.7.3.2   Cord strain relief     N/A   

   
 
Page  39   of  90   Report No. :  60404487 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
    Solid square and rectangular (flatwise bending) 
winding wire, cross - sectional area (mm 2
)   ..............   :     N/A  
J.2/J.3  
Tests and Manufacturing   (See separate test report)  
  
K   SAFETY INTERLOCKS  
N/A  
K.1   General requirements  
N/A  
  Instructional safeguard   ................................ ..........   :     N/A  
K.2   Components of safety interlock safeguard mechanism  
N/A  
K.3   Inadvertent change of operating mode   
N/A  
K.4   Interlock safeguard overrid e   
N/A  
K.5   Fail - safe  
N/A  
K.5.1   Under single fault condition     N/A  
K.6   Mechanically operated safety interlocks   
N/A  
K.6.1   Endurance requirement     N/A  
K.6.2   Test method and compliance   ................................   :     N/A  
K.7   Interlock circuit isolation   
N/A  
K.7.1   Separation distance   for contact gaps & interlock 
circuit elements     N/A  
  In circuit connected to mains, separation distance 
for contact gaps (mm) ................................ ............   :     N/A  
  In circuit isolated from mains, separation distance 
for contact gaps (mm) ................................ ............   :     N/A  
  Electric strength test before and aft er the test of 
K.7.2   ................................ ................................ ......   :     N/A  
K.7.2   Overload test, Current (A)   ................................ .....   :     N/A  
K.7.3   Endurance test      N/A  
K.7.4   Electric strength test      N/A  
L   DISCONNECT DEVICES  
N/A  
L.1   General requirements  
  N/A  
L.2   Permanently connected equipment   
  N/A  
L.3   Parts that remain  energized   
  N/A  
L.4   Single - phase equipment   
  N/A  
L.5   Three - phase equipment   
  N/A  
L.6   Switches as disconnect devices   
  N/A  
L.7   Plugs as disconnect devices   
  N/A  
L.8   Multiple power sources   
  N/A   

   
 
Page  54   of  90   Report No. :  60404487 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  
B.3, B.4   TABLE: Abnormal operating and fault condition tests  
P  
Ambient temperature T
amb   (  C)   ................................ .....................   :   2 1 - 2 3  
  
Power source for EUT: Manufacturer, model/type, outputrating   ..   :   -  
  
Component No.   Condition   Supply 
voltage 
(V)   Test 
tim e   Fuse no.   Fuse 
current 
(A)   Observation  
Ventilation 
openings   Block ed   14.4   2   h   -   -   FI   :  2.16   A, NO,   
CT (Monitor  body   : 3 8.0    C,  
Power key knob body   :  2 6.1  
 C,  Enclosure near media 
button   : 29.4   C,   Ambient : 
2 1.2    C, NCD, NH  
Speaker output   Max. non -
clipp ed output   14.4   2   h   -   -   FI  : Max.  3.43   A, NO,   
CT ( Amp IC body (IC163) : 
80.4   C ,   Monitor  body   : 3 8.0  
 C,   Power key knob body   : 
26.3    C,  Enclosure near 
media button   : 29.5   C,  
Ambient : 2 1.5    C, NCD, NH  
Speaker output   SC   14.4   1   h   -   -   FI  :  0.5  -   1.5 5   A ,  IP ,   NCD, 
NH  
IC101(3,8)   SC   14.4   1   h   -   -   FI  :  0.5 A ,  CD(IC101) , NH  
IC902(1,6)   SC   14.4   1   h   -   -   FI  :  0.5 A ,  CD(IC902) , NH  
Supplementary information:  
Abbreviation:   
FI  –   Final Input Current; IP  –   Internal protection operated;   NO  –   Normal Operated;  
CD  –   Componen t Damaged (list damaged components); NCD  –   No Component Damaged;  
NH  –   No Hazard ;  CT  –   Constant temperatures were obtained (list components: temperature;);  
NB  –   No indication of dielectric breakdown; YB  –   Dielectric breakdown (indicate time and location);  
NC  –   Cheesecloth remained intact; YC  –   Cheesecloth charred or flamed;  
  

   
 
Page  61   of  90   Report No. :  60404487 001  
 
IEC 62368 - 1  –   ATTACHMENT 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
 10.5.1   Add   the following after the first paragraph:  
For RS 1 compliance is checked by measurement 
under the following conditions:  
In addition to the normal operating condi tions, all 
controls adjustable from the outside by hand, by any 
object such as a tool or a coin, and those internal 
adjustments or presets which are not locked in a reliable 
manner, are adjusted so as to give maximum radiation 
whilst maintaining an intelli gible picture for 1 h, at the 
end of which the measurement is made.  
NOTE Z1  Soldered joints and paint lockings are examples of 
adequate locking.  
The dose - rate is determined by means of a  radiation 
monitor with an effective area of 10 cm², at any point 10  
cm from the outer surface of the apparatus.  
Moreover, the measurement shall be made under fault 
conditions causing an increase of the high - voltage, 
provided an intelligible picture is maintained for 1 h, at 
the end of which the measurement is made.  
For RS 1, the dose - rate shall not exceed 1 μSv/h taking 
account of the background level.  
NOTE Z2  These values appear in Directive 96/29/Euratom of 13 May 
1996.     N/A  
10.6.1   Add   the following paragraph to the end of the 
subclause:  
EN 71 - 1:2011, 4.20 and the relat ed tests methods and 
measurement distances apply.     N/A  
10.Z1   Add   the following new subclause after 10.6.5.  
10.Z1 Non - ionizing radiation from radio frequencies 
in the range 0 to 300 GHz  
The amount of non - ionizing radiation is regulated by 
European Council  Recommendation 1999/519/EC of 12 
July 1999 on the limitation of exposure of the general 
public to electromagnetic fields (0 Hz to 300 GHz).  
For intentional radiators, ICNIRP guidelines should be 
taken into account for Limiting Exposure to Time -
Varying Elec tric, Magnetic, and Electromagnetic Fields 
(up to 300 GHz). For hand - held and body - mounted 
devices, attention is drawn to EN 50360 and EN 50566     N/A  
G.7.1   Add   the following note:  
NOTE Z1  The harmonized code designations corresponding to the 
IEC cord type s are given in Annex ZD.     P   

   
 
Page  77   of  90   Report No. :  60404487 001  
 
IEC 62368 - 1_ATTACHMENT 2  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  are offered, an administrator (for example, parental 
restrictions, business/educational administrators, 
etc.) shall be able to  lock any optional settings into a 
specific configuration.  
 
The personal music player shall be supplied with 
easy to understand explanation to the user of the 
dose management system, the risks involved, and 
how to use the system safely. The user shall be 
ma de aware that other sources may significantly 
contribute to their sound exposure, for example 
work, transportation, concerts, clubs, cinema, car 
races, etc.  
10.6.5.2   Dose - based warning and requirements  
 
When a dose of 100 %  CSD  is reached, and at lea st 
at every 100 % further increase of  CSD , the device 
shall warn the user and require an 
acknowledgement. In case the user does not 
acknowledge, the output level shall automatically 
decrease to compliance with class RS1.  
 
The warning shall at least clearly   indicate that 
listening above 100 %  CSD  leads to the risk of 
hearing damage or loss.     N/A  
10.6.5.3   Exposure - based requirements  
 
With only dose - based requirements, cause and 
effect could be far separated in time, defying the 
purpose of educating users abo ut safe listening 
practice. In addition to dose - based requirements,  a 
PMP shall therefore also put a limit to the short - term 
sound level a user can listen at.  
 
The exposure - based limiter (EL) shall automatically 
reduce the sound level not to exceed 100 dB (A) or 
150 mV integrated over the past 180 s, based on 
methodology defined in EN 50332 - 3.  
The EL settling time (time from starting level 
reduction to reaching target output) shall be 10 s or 
faster.  
 
Test of EL functionality is conducted according to 
EN 50 332 - 3, using the limits from this clause. For 
equipment provided as a package (player with its 
listening device), the level integrated over 180 s 
shall be 100 dB or lower. For equipment provided 
with a standardized connector, the unweighted level 
integrate d over 180 s shall be no more than 150 mV 
for an analogue interface and no more than  - 10 
dBFS for a digital interface.  
 
NOTE In case the source is known not to be music (or test 
signal), the EL may be disabled.     N/A  
10.6.6  
Requirements for listening devic es (headphones, earphones, etc.)  
N/A