2017 INFINITI QX60 HYBRID First Responder´s

Page 17 of 45

INFINITI QX60 HYBRID 2017  First Responder´s 3. Emergency Response Steps
• Failure to properly shut down the high-voltage electrical system before the
Emergency Response Procedures are performed will result in serious injury or death
from elec

Page 18 of 45

INFINITI QX60 HYBRID 2017  First Responder´s 3-1 Preparation Items
Preparation Items
SpecificationPurpose
PPE
(personal protective equipment): Up to 1,000V For protection from high-
voltage electrical shock.
Insulated gloves Insulated shoes
–

Page 19 of 45

INFINITI QX60 HYBRID 2017  First Responder´s 3-1.1 Personal Protective Equipment (PPE) Protective Wear Control
Perform
an inspection of the Personal Protective Equipment (PPE) items before beginning work. Do not use
any damaged PPE items.
3-1.2

Page 20 of 45

INFINITI QX60 HYBRID 2017  First Responder´s 3-2 Vehicle Immobilization and StabilizationIf possible, immobilize the vehicle by turning the 12-volt system OFF and stabilize it with a wheel chock(s) .
Stabilize the vehicle with cribbing, by remov

Page 21 of 45

INFINITI QX60 HYBRID 2017  First Responder´s When arriving to an incident involving an Infiniti QX60 HYBRID, the vehicle should be approached with
caution
and inspected for the level of damage. In addition to overall vehicle condition (location

Page 22 of 45

INFINITI QX60 HYBRID 2017  First Responder´s • The vehicle contains parts that contain powerful magnets. If a person who is wearing
a
pacemaker or other medical device is close to these parts, the medical device may be
affected by the magnets.

Page 23 of 45

INFINITI QX60 HYBRID 2017  First Responder´s Primary Procedure
NO
TE:
Before disconnecting the 12-volt battery terminal, if necessary, lower the windows, adjust
the steering column, adjust the seats, unlock the doors, etc. Once 12-volt battery i

Page 24 of 45

INFINITI QX60 HYBRID 2017  First Responder´s 5. Pull release handle (1) and pull up release lever (2) to open hood.
6.
Remove traction motor inverter cover (1) .
7. Disconnect negative (-) battery cable and cover it with insulated tape.
8. Wait