Primary Procedure
NO
TE:
Before disconnecting the 12-volt battery terminal, if necessary, lower the windows, adjust
the steering column, adjust the seats, unlock the doors, etc. Once 12-volt battery is
disconnected, power controls will not operate.
1. If possible, check the READY indicator status in the instrument cluster. If it is on, the high-
voltage
system is active.
2. Place the shift selector in the Park (P) position.
3. Push the ignition switch once to turn OFF the high- voltage system. Verify that the READY indicator is off
and then continue to the next steps to open the hood
for 12-volt battery negative cable access.
If the READY indicator does not turn off, refer to
Alternate Procedure 1 (Remove Fuses) (FRG–25).
4.
If possible, keep the Infiniti Intelligent Key at least
5 meters (16 feet) away from the vehicle. AAYIA0191ZZ
AAYIA0271ZZ
AAYIA0340ZZ
FRG–23
d. If the liftgate cannot be opened with the
instrument panel switch, liftgate opener switch,
or key fob due to a discharged battery, follow
these steps:
• Remove the cover (A) on the inside of the liftgate.
• Move the lever (B) as illustrated to open liftgate.
* You must have the Infiniti Intelligent Key within approximately 1 meter (3 feet) range of
liftgate opener switch to use the liftgate opener switch function.
6. Open luggage board in the cargo area using the handle (A) .
7. Open service plug access cover. AAYIA0316ZZ
AAYIA0267ZZ
AAYIA0268ZZ
FRG–29