Page 108 of 181
PETROL INJECTION
Fault finding – Conformity check17B
17B-108V12 MR-372-J84-17B000$450.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
START SUB-FUNCTION
NOTESOnly check conformity after a thorough check with the diagnostic tool.
The values shown in this conformity check are given as a guide.
Application condition: engine off, ignition on.
Order FunctionParameter or Status
Checked or ActionDisplay and
notes Fault finding
1 Starting ET076: StartingAUTHORISEDThe authorisation to start is
given once the fuel pump is
pressurised and if the
motorised throttle has
completed its stop and limp-
home position programming
phase.
2Actuator relay
controlET048: Actuator relay
controlACTIVE
INACTIVEIf ACTIVE apply the interpretation
of DF084 Actuator relay control
circuit.
3 Battery voltage PR071: Computer feed
voltage11 V < PR071
<15VIf there is a fault, use
interpretation of PR071
Computer supply voltage.
JSAA741.0
Page 109 of 181

PETROL INJECTION
Fault finding – Conformity check17B
17B-109V12 MR-372-J84-17B000$450.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
PROTECTION SUB-FUNCTION
NOTESOnly check conformity after a thorough check with the diagnostic tool.
The values shown in this conformity check are given as a guide.
Application condition: engine off, ignition on.
Order FunctionParameter or Status
Checked or ActionDisplay and notes Fault finding
1Code
programmedET006: Code
programmedStates whether the
immobiliser code has been
programmed by the
computer or not.
YES: Code programmed
NO: Code not programmed
into the injection computer.If NO, contact the
Techline
2Engine
immobiliserET003: Engine
immobiliserIndicates the status of the
immobiliser system.
INACTIVE: The injection
computer has recognised the
immobiliser code transmitted
by the UCH.
ACTIVE: the injection
computer does not recognise
the immobiliser code
transmitted by the UCH.If ET003 is
inconsistent, carry
out a multiplex
network test using
the diagnostic tool. If
the test is correct
check the UCH.
3Impact
detectedET077: Impact
detectedYES
NOIf YES, switch off the
ignition for 10
seconds, then
switch it back on so
the engine can be
restarted. Then clear
any faults.
4 Starting ET076: StartingAUTHORISEDThe authorisation to
start is given once
the fuel pump is
pressurised and if
the motorised
throttle has
completed its stop
and limp-home
position
programming phase.
JSAA741.0
Page 113 of 181

PETROL INJECTION
Fault finding – Conformity check17B
17B-113V12 MR-372-J84-17B000$450.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
FUEL CIRCUIT SUB-FUNCTION
NOTESOnly check conformity after a thorough check with the diagnostic tool.
The values shown in this conformity check are given as a guide.
Application conditions: Engine warm, at idle speed.
Order FunctionParameter or Status
Checked or ActionDisplay and notes Fault finding
1Engine
speedPR055: Engine
speedIndicates the engine's speed of
rotation in rpm.
700 rpm < PR055 < 6500 rpmIn the event of a
fault, apply the
interpretation for
DF154 Flywheel
signal sensor
circuit.
2
Motorised
throttlePR014: Idling
speed
correctionShows engine idling speed
correction value.
0 rpm < PR014 < 224 rpm.
The idle speed regulator performs all
of the calculations that allow the idle
speed actuator to be controlled
physically: the motorised throttle.
This regulator has a built-in adaptive
component (variation and ageing
programming).WITHOUT
3ET054: Idle speed
regulationACTIVE
INACTIVEIf INACTIVE apply
the interpretation for
ET054 Idling speed
regulation.
4 PR010: Idle speed
regulation
setpointThe idle speed regulation setpoint
depends on the coolant and oil
temperature, the position of the gear
lever, and which electrical
consumers are operating.
752 rpm < PR010 < 1216 rpm.
If a manifold pressure sensor fault is
present or stored, the idle speed
setting is 896 rpm.In the event of a
fault, apply the
interpretation of
ET054 Idle speed
regulation.
JSAA741.0
Page 114 of 181

PETROL INJECTION
Fault finding – Conformity check17B
17B-114V12 MR-372-J84-17B000$450.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
FUEL CIRCUIT SUB-FUNCTION (continued 1)
Order FunctionParameter or Status
Checked or ActionDisplay and notes Fault finding
5
Motorised
throttlePR090: Idle speed
regulation
programming
value- 12% < PR090 < 12%
PR090, an adaptive built-in action, is
a stored parameter designed to
program variation and engine ageing
for the idle speed regulator. These
are programmed only when the
engine is idling and warm, and no
electrical consumers (electrical
windscreen, air conditioning, GMV,
power steering) have been selected.
Therefore it adjusts slowly.
WITHOUT
6 PR141: Integral idling
speed
regulation
correction4.7% < PR141 < 32%
The built-in correction is
continuously calculated to take into
account consumer demand for air.
7 Motorised
throttlePR091: Theoretical idle
speed
regulation OCR5% < PR091 < 50%
When the conditions for regulation
are met, the idle regulator continually
repositions the motorised throttle to
keep the engine speed at the idling
speed setting. The motorised throttle
opening ratio required to adhere to
the engine speed setpoint is then
given by parameter PR091.
JSAA741.0
Page 115 of 181

PETROL INJECTION
Fault finding – Conformity check17B
17B-115V12 MR-372-J84-17B000$450.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
FUEL CIRCUIT SUB-FUNCTION (continued 2)
Order FunctionParameter or Status
Checked or ActionDisplay and notes Fault finding
8
Oxygen sensorET055: Upstream
sensor richness
loop.Loop openIn the event of a fault,
apply the
interpretation of
ET055 Upstream
sensor richness
loop.
9 PR138: Richness
correction0% < PR138 < 100%
In loop mode, the richness
correction corrects the
injection duration to
obtain a fuel mixture as
close as possible to a
richness of 1. The
correction value varies
around 50.
WITHOUT 10 PR144: Self-adapting
richness offset0 < PR144 < 255
This parameter is used to
detect any tendency of the
injection system to
increase or decrease the
richness.
11 PR143: Self-adapting
richness gain0 < PR143 < 255
This parameter is used to
detect any tendency of the
injection system to
increase or decrease the
richness.
12 Injection PR101: Duration of
injectionAT IDLE SPEED
2ms
13Fuel
consumptionPR103: Instantaneous
fuel
consumptionAT IDLE SPEED
PR103 12/h
JSAA741.0
Page 116 of 181
PETROL INJECTION
Fault finding – Conformity check17B
17B-116V12 MR-372-J84-17B000$450.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
FUEL CIRCUIT SUB-FUNCTION (continued 3)
Order FunctionParameter or Status
Checked or ActionDisplay and notes Fault finding
14 Fuel pump ET047: Fuel pump
control circuitACTIVE
INACTIVEIf INACTIVE
interpretation for
DF085 Fuel pump
relay control circuit.
15 Fuel pump AC015: Fuel pump
relayThe fuel pump should be
heard operatingIn the event of a fault,
apply the
interpretation of
AC015 Fuel pump
relay.
JSAA741.0
Page 129 of 181
PETROL INJECTION
Fault finding – Conformity check17B
17B - 129V12 MR-372-J84-17B000$495.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
START SUB-FUNCTION
NOTESOnly check conformity after a full check with the diagnostic tool.
The values shown in this conformity check are given as a guide.
Application conditions: Engine warm, idling.
Order FunctionParameter or Status
checked or ActionDisplay and
Notes Fault finding
1 Starting ET076: StartingAUTHORISEDThe authorisation to start is
given once the fuel pump is
pressurised and if the
motorised throttle has
completed its stop and limp-
home position programming
phase.
2Actuator relay
controlET048: Actuator relay
controlACTIVE
INACTIVEIf ACTIVE apply the interpretation
of DF084 Actuator relay control
circuit.
3 Battery voltage PR071: Computer
supply
voltage13 V < PR071
<15VIf there is a fault, use
interpretation of PR071
Computer supply voltage.
JSAA741.0
Page 130 of 181

PETROL INJECTION
Fault finding – Conformity check17B
17B - 130V12 MR-372-J84-17B000$495.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
PROTECTION SUB-FUNCTION
NOTESOnly check conformity after a full check with the diagnostic tool.
The values shown in this conformity check are given as a guide.
Application conditions: Engine warm, idling.
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
1Code
programmedET006: Code
programmedIndicates whether
immobiliser code
programmed into
computer.
–YES: Code
programmed
–NO: Code not
programmed into
injection computer.If NO, contact the
Techline
2Engine
immobiliserET003: Engine
immobiliserIndicates the status of the
immobiliser system.
–INACTIVE: The
injection computer has
recognised the
immobiliser code
transmitted by the UCH.
–ACTIVE: the injection
computer does not
recognise the
immobiliser code
transmitted by the UCH.If ET003 is
inconsistent, carry out
a multiplex network
test using the
diagnostic tool. If the
test is correct check
the UCH.
3Impact
detectedET077: Impact
detectedYES
NOIf YES, switch off the
ignition for
10 seconds, then
switch it back on so
the engine can be
restarted. Then clear
any faults.
4 Starting ET076: StartingAUTHORISEDThe authorisation to
start is given once the
fuel pump is
pressurised and if the
motorised throttle has
completed its stop
and limp-home
position programming
phase.
JSAA741.0