PETROL INJECTION
Fault finding – System operation17B
17B - 7V12 MR-372-J84-17B000$090.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48PETROL INJECTION
Fault finding – System operation
1. SYSTEM OPERATION
Composition
The injection system consists of the:
– accelerator potentiometer,
– accelerator pedal switch,
– TDC sensor,
– atmospheric pressure sensor,
– air temperature sensor,
– coolant temperature sensor,
– freon pressure sensor,
– upstream oxygen sensor,
– downstream oxygen sensor,
– cruise control switch,
– steering column switch,
– cruise control on/off switch,
– brake lights switch,
– fuel vapour absorber,
– injection computer,
– motorised throttle valve,
– four injectors,
– four pencil coils,
– + turbocharging pressure sensor,
– coolant pump
– turbocharging solenoid valve.
Computer
SAGEM S3000 flash EEPROM 128-track computer controlling the injection and the ignition.
Multipoint injection in sequential mode.
Connections to the other computers:
– Protection and Switching Unit (UPC)
– Passenger Compartment Control Unit (UCH),
– Automatic Transmission Electronic Control Unit (AUTO ECU).
JSAA741.0
MR-372-J84-17B000$090.mif
PETROL INJECTION
Fault finding – System operation17B
17B - 9V12 MR-372-J84-17B000$090.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
2. OPERATIONAL SAFETY
Warning lights illumination
The S3000 injection system manages the illumination of three warning lights and the issuing of warning messages
according to the severity of the faults detected, to inform the customer and to direct fault finding.
The injection computer manages the illumination of warning lights and warning messages displayed on the instrument
panel. These warning lights illuminate during the starting phase and in the event of an injection fault or engine
overheating.
The warning light illumination signals reach the instrument panel via the multiplex network.
Warning light illumination principle
During the starting phase (START button pressed) the OBD (On Board Diagnostic) warning light comes on for
approximately 3 seconds then goes out.
If there is an injection fault (severity 1), the INJECTION FAULT written message lights up followed by the SERVICE
warning light. It indicates a reduced level of operation and a limited safety level.
The driver should carry out repairs as soon as possible.
Components involved:
– motorised throttle valve,
– accelerator pedal potentiometer,
– inlet manifold pressure sensor,
–computer,
– actuator feed,
– computer feed.
If there is a serious injection fault (severity 2), the red engine symbol and the word STOP appear (display with
information display only), with the ENGINE OVERHEATING written message followed by the STOP warning light
and a buzzer. If this happens, the vehicle must be stopped immediately.
When a fault causing excessive pollution in the exhaust fumes is detected, the orange OBD warning light, an engine
symbol, will be lit:
–flashing in the event of a fault which might irreparably damaged the catalytic converter (destructive misfire). If this
happens you must stop the vehicle immediately,
–constantly in the case of non-compliance with the anti-pollution standards (pollutant misfire, catalytic converter
fault, oxygen sensor faults, inconsistency between the oxygen sensors and canister fault).
Mileage travelled with fault
This parameter serves to measure the distance travelled with one of the injection fault warning lights on: level 1 fault
warning light (amber), coolant temperature overheating warning light, or OBD warning light.
The counter can be reset to 0 using the diagnostic tool.
JSAA741.0
PETROL INJECTION
Fault finding – Allocation of computer tracks17B
17B - 13V12 MR-372-J84-17B000$135.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
Connector (B), 48 tracks:
Track Description
A1
A2
A3
A4
B1
B2
B3
B4
D1
D2
D3
D4
E1
E2
E3
E4
F1
F2
F3
F4
G1
G2
G3
G4
H1
H2
H3
H4
I1
I2
I3
I4
J1
J2
J3
J4
K1
K2
K3
K4
L1
L2
L3
L4
M1
M2
M3
M4Injector 1 - control
Injector 2 - control
Injector 3 - control
Injector 4 - control
Not used
Pinking sensor screening
Pinking sensor + signal
Pinking sensor - signal
Not used
Not used
Motorised throttle valve potentiometer gang 2 signal
Computer self-power
- turbocharging pressure sensor
Air temperature sensor signal
Air temperature sensor earth
Engine speed and position sensor signal
Turbocharging pressure sensor signal
Coolant temperature sensor signal
Engine speed and position sensor signal
Coolant temperature sensor earth
+ turbocharging pressure sensor
Motorised throttle potentiometer + 5 V feed
Motorised throttle valve potentiometer gang 1 signal
Motorised throttle valve potentiometers common earth
Not used
Manifold pressure sensor + 5 V feed
Manifold pressure sensor signal
Manifold pressure sensor earth
Not used
Not used
Not used
Not used
Not used
Air conditioning pressostat signal
AC pressure switch + 5 V supply
Not used
Not used
Air conditioning pressostat earth
Engine CAN LOW multiplex connection
Engine CAN HIGH multiplex connection
Electronic earth
Not used
Not used
- coolant pump
Electronic earth
Battery + feed via the UPC
+ motorised throttle valve motor
- motorised throttle valve motor
JSAA741.0
PETROL INJECTION
Fault finding – Fault summary table17B
17B - 17V12 MR-372-J84-17B000$270.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48PETROL INJECTION
Fault finding – Fault summary table
Tool
faultsHexadecimal
DTC codesDescriptionLevel 1 fault
warning lightNo warning
light onOBD warning
light
DF0010115Coolant temperature
sensor circuit1.DEF
DF0020110Air temperature sensor
circuit1.DEF
DF0040235Turbocharging pressure
sensor circuit1.DEF/2.DEF 1.DEF/2.DEF
DF0080225Pedal potentiometer
circuit gang 1CO.0/CC.1
1.DEF
DF0092120Pedal potentiometer
circuit gang 2CO.0/CC.1
DF0110641 Sensor feed voltage no. 1 1.DEF/2.DEF
DF0120651 Sensor feed voltage no. 2 1.DEF/2.DEF
DF0260201Cylinder 1 injector control
circuitCO/ CC.0
CC.1
DF0270202Cylinder 2 injector control
circuitCO/ CC.0
CC.1
DF0280203Cylinder 3 injector control
circuitCO/ CC.0
CC.1
DF0290204Cylinder 4 injector control
circuitCO/ CC.0
CC.1
DF0370633 Engine immobiliser 1.DEF
DF0380606 Computer 1.DEF
DF0460560 Battery voltage 1.DEF
DF0490530 Refrigerant sensor circuit 1.DEF
DF0540243Turbocharging solenoid
valve control circuitCO/ CC.0
CC.1
JSAA741.0
MR-372-J84-17B000$270.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
17B-21V12 MR-372-J84-17B000$315.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48PETROL INJECTION
Fault finding – Interpretation of faults
DF001
PRESENT
COOLANT TEMPERATURE SENSOR CIRCUIT
1.DEF : value outside tolerance range
NOTESPriority for dealing with a combination of faults:
Deal with fault DF011 Sensor supply voltage no. 1 first if it is present or stored.
Special note:
The OBD warning light is lit.
Check the cleanliness and condition of the coolant temperature sensor and its connections.
Disconnect the battery and the injection computer.
Check the cleanliness and condition of the connections.
Repair if necessary.
Using the universal bornier, check the insulation and continuity on the following connections:
Computer, connector B track F2 track B2 of the coolant temperature sensor
Computer, connector B track F4 track B1 of the coolant temperature sensor
Repair if necessary.
Measure the resistance of the coolant temperature sensor between tracks B1 and B2.
Replace the coolant temperature sensor if the resistance is not 12.6 k± 1.1 kat - 10°C
2.2 k±112at 25°C
810±39at 50°C
282.6±7.8at 80°C
114.6±2.6at 110°C
87.7±1.9at 120°C
If the fault is still present, deal with the other faults then proceed to the conformity check.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
JSAA741.0
MR-372-J84-17B000$315.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
17B-26V12 MR-372-J84-17B000$315.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
DF011
PRESENT
OR
STOREDSENSOR SUPPLY VOLTAGE NO. 1
1.DEF : voltage outside tolerances
2.DEF : internal electronic fault
NOTESPriority for dealing with a combination of faults:
Deal with the other faults first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after:
– the ignition is switched on.
– loss of dialogue between the inter-systems (ESP, CC/SL),
– power loss when accelerating.
Special note:
–level 1 fault warning light illuminated,
– Throttle valve defect mode types 1 and 2.
Check the cleanliness and condition of the throttle valve connections.
Check the cleanliness and condition of the pedal potentiometer connections.
Disconnect the battery and the injection computer.
Check the cleanliness and condition of the connections.
Repair if necessary.
Sensor feed No. 1 is reserved for the following components:
– motorised throttle valve,
– coolant temperature sensor,
– pedal potentiometer gang 1,
– upstream and downstream oxygen sensors,
– motorised throttle potentiometer gangs 1 and 2.
If, with sensors disconnected the voltage is still less than 4.9 V or greater than 5.1 V:
– check the insulation from earth of the + 5 V line of each of its sensors.
Use the "Universal bornier" to check the insulation and continuity of the following connections:
Computer, connector B, track G2 Track 2 of the throttle valve
Computer, connectorA, track G2 Track 3 of the pedal potentiometer gang 1
Repair if necessary.
If the fault is still present, there is a computer fault. Contact the Techline.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
S3000_V44_DF011/S3000_V48_DF011JSAA741.0
PETROL INJECTION
Fault finding – Conformity check17B
17B-92V12 MR-372-J84-17B000$450.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
FUEL CIRCUIT SUB-FUNCTION
NOTESOnly check conformity after a thorough check with the diagnostic tool.
The values shown in this conformity check are given as a guide.
Application condition: engine off, ignition on.
Order FunctionParameter or Status
Checked or ActionDisplay and notes Fault finding
1Engine
speedPR055: Engine speedIndicates the engine's speed
of rotation in rpm.
0 rpm < PR055 < 500 rpmIn the event of a fault
apply the interpretation
for DF154 Flywheel
signal sensor circuit.
2
Motorised
throttlePR014: Idling speed
correctionShows engine idling speed
correction value.
PR014= 0rpm.
The idle speed regulator
performs all of the
calculations that allow the idle
speed actuator to be
controlled physically: the
motorised throttle. The
functional component of the
regulator is adaptive
(variation programming and
ageing).WITHOUT
3 PR054: Idle speed
regulationACTIVE
INACTIVEIf ACTIVE apply the
interpretation for ET054
Idle speed regulation.
4 PR010: Idle speed
regulation
setpointThe idle speed regulation
setpoint depends on the
coolant and oil temperature,
the position of the gear lever,
and which electrical
consumers are operating.
752 rpm. < PR010
< 1216 rpm.
If a manifold pressure sensor
fault is present or stored, the
idle speed setting is 896 rpm.In the event of a fault
apply the interpretation
for ET054, Idle speed
regulation.
JSAA741.0
PETROL INJECTION
Fault finding – Conformity check17B
17B-96V12 MR-372-J84-17B000$450.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
SUB FUNCTION: CIRC. (TURBOCHARGING/INLET)
NOTESOnly check conformity after a thorough check with the diagnostic tool.
The values shown in this conformity check are given as a guide.
Application condition: engine off, ignition on.
Order FunctionParameter or Status
Checked or ActionDisplay and notes Fault finding
1
Air circuit
pressurePR035: Atmospheric
pressure700 mb < PR035
<1047mbIf not consistent, check
that PR035 = PR032 =
local atmospheric
pressure, with the engine
stopped and ignition on.
In the event of a fault apply
the interpretation for PR032
Inlet pressure. 2 PR032: Inlet pressure121.5 mb < PR035
<2200mb
3
TurbochargingPR041: Turbocharging
pressure121.5 mb < PR041
<2200mb
Default value:
1016 mbIn the event of a fault, apply
the interpretation of DF004
Turbocharging pressure
sensor circuit.
4 PR104: Turbocharging
solenoid valve
OCR setpointShows the
turbocharging
solenoid valve
opening ratio.WITHOUT
5 Air temperature PR058: Air temperature- 40°C < PR058
< 120°CIn the event of a fault, apply
the interpretation of DF002
Air temperature sensor
circuit.
6Coolant
temperaturePR064: Coolant
temperature- 40°C < PR064
< 120°CIn the event of a fault, apply
interpretation of DF001 Air
temperature sensor
circuit.
7 Turbocharging AC004: Turbocharging
solenoid valveThe turbocharging
solenoid valve
should be heard
operatingIn the event of a fault, apply
interpretation of DF054
Turbocharging solenoid
valve control circuit.
JSAA741.0