Page 17 of 37
82A-17
AFTER REPAIRAfter replacing the computer, consult the Replacement of components section.
Deal with any faults displayed by the diagnostic tool.
Clear the faults from the computer memory using command RZ001 Fault memory.
V1 MR-376-X76-82A000$070.mif
ENGINE IMMOBILISER
Fault finding – Interpretation of faults82A
SVT
Vdiag No.: 04
DF005
PRESENT
OR
STOREDSVT INTERNAL FAULT
NOTESSwitch on the vehicle + after ignition feed.
Replace the anti-theft tracking unit (see MR 388, 451, 364, 370, 377, 423, 430 or 374, Mechanical, 82A,
Immobiliser, Tracking unit: Removal - Refitting).
If the fault is still present, contact the Techline.
SVT_V04_DF005
Page 18 of 37
82A-18
AFTER REPAIRAfter replacing the computer, consult the Replacement of components section.
Deal with any faults displayed by the diagnostic tool.
Clear the faults from the computer memory using command RZ001 Fault memory.
V1 MR-376-X76-82A000$070.mif
ENGINE IMMOBILISER
Fault finding – Interpretation of faults82A
SVT
Vdiag No.: 04
DF006
PRESENT
OR
STOREDSVT SYSTEM INTERNAL FAULT
NOTESSwitch on the vehicle + after ignition feed.
Replace the anti-theft tracking unit (see MR 388, 451, 364, 370, 377, 423, 430 or 374, Mechanical, 82A,
Immobiliser, Tracking unit: Removal - Refitting).
If the fault is still present, contact the Techline.
SVT_V04_DF006
Page 19 of 37
82A-19
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the faults from the computer memory using command RZ001 Fault memory.
V1 MR-376-X76-82A000$070.mif
ENGINE IMMOBILISER
Fault finding – Interpretation of faults82A
SVT
Vdiag No.: 04
DF007
PRESENTCONFIGURATION
NOTESSwitch on the vehicle + after ignition feed.
Configure the system (see Configuration and programming).
Note:
After configuring, switch off the ignition, wait 2 minutes then switch on the ignition again to allow the configuration
to register.
Check the computer configuration by reading configuration LC001 External GPS aerial.
SVT_V04_DF007P
Page 20 of 37
82A-20V1 MR-376-X76-82A000$075.mif
82A
SVT
Vdiag No.: 04
MAIN SCREEN or SUB-FUNCTION: STARTING
NOTESOnly check conformity after a full check with the diagnostic tool.
FunctionStatus or parameter checked
or actionNotes Fault finding
ACCESS/
SAFETYET001:SVT operational noneRefer to the
interpretation of ET001
ET002:System activation
requestnoneRefer to the
interpretation of ET002
ET003:Internal battery noneRefer to the
interpretation of ET003
ET004:Locating system
activenoneRefer to the
interpretation of ET004
ET005:Tracker active noneRefer to the
interpretation of ET005
ET006:SIM card noneRefer to the
interpretation of ET006
PR001Battery charge noneIn the event of a fault,
apply the interpretation
of fault DF004 Battery
internal fault.
SVT_V04_CCONF
ENGINE IMMOBILISER
Fault finding – Conformity check
Page 21 of 37
82A-21V1 MR-376-X76-82A000$080.mif
82A
SVT
Vdiag No.: 04
Tool status Diagnostic tool title
ET001SVT operational
ET002System activation request
ET003Internal battery
ET004Locating system active
ET005Tracker active
ET006SIM card
ENGINE IMMOBILISER
Fault finding – Status summary table
Page 22 of 37
82A-22
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the faults from the computer memory using command RZ001 Fault memory.
V1 MR-376-X76-82A000$090.mif
82A
SVT
Vdiag No.: 04
ET001 SVT OPERATIONAL
STATUS DEFINITIONYES: indicates that the anti-theft tracking unit is operational
NO: indicates that the anti-theft tracking unit is not operational
SVT_V04_ET001
ENGINE IMMOBILISER
Fault finding – Interpretation of statuses
Page 23 of 37
82A-23
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the faults from the computer memory using command RZ001 Fault memory.
V1 MR-376-X76-82A000$090.mif
ENGINE IMMOBILISER
Fault finding – Interpretation of statuses82A
SVT
Vdiag No.: 04
ET002 SYSTEM ACTIVATION REQUEST
STATUS DEFINITIONACTIVE: indicates that system activation was requested.
INACTIVE: indicates that system activation was not requested.
SVT_V04_ET002
Page 24 of 37
82A-24
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the faults from the computer memory using command RZ001 Fault memory.
V1 MR-376-X76-82A000$090.mif
ENGINE IMMOBILISER
Fault finding – Interpretation of statuses82A
SVT
Vdiag No.: 04
ET003 INTERNAL BATTERY
STATUS DEFINITIONOK: indicates that the battery is in good condition
NOK: indicates that the battery is not in good condition
SVT_V04_ET003