13B-44
MR-372-J84-13B050$390.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No. 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF011
PRESENT
OR
STOREDSENSOR SUPPLY VOLTAGE NO. 1
1. DEF: Signal outside lower limit
2. DEF: Signal outside upper limit
NOTESPriorities when dealing with a number of faults:
If one or more of the following faults are present at the same time:
–DF009 Pedal potentiometer circuit gang 2, check that the pedal sensor
connector is connected correctly.
–DF007 Rail pressure sensor circuit, check that the rail pressure sensor connector
is connected correctly.
–DF056 Air flow sensor circuit, check that the air flow sensor connector is
connected correctly.
–DF209 EGR valve position sensor circuit, check that the EGR valve position
sensor connector is connected correctly.
–DF1003 Particle filter differential pressure sensor circuit, check that the
connector of the particle filter differential pressure sensor is connected correctly.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the ignition has been switched on.
Special notes:
If the fault is present:
– The cruise control/speed limiter is deactivated.
– Power is restricted.
–The level 1 warning light is lit.
–The OBD warning light is lit.
Use CLIO III, MODUS, MEGANE II ph2, SCENIC II ph2 and KANGOO II Wiring
diagrams Technical Note.
The sensors connected to supply no. 1 are:
–rail pressure sensor, component code1032,
–accelerator pedal potentiometers gang 2 sensor, component code921,
–air flowmeter sensor, component code799,
–EGR valve position sensor, component code 1460.
–particle filter differential pressure sensor, component code 1290.
To locate the potentially defective sensor and/or connection, disconnect one of these sensors and then check
whether the fault becomes stored.
If the fault is still present, start the operation again with each sensor (one by one).
(Wait several seconds between each disconnection to allow the computer to detect the fault)
If the fault is stored after a disconnection, replace the faulty sensor or repair its connection.
Clear the faults created by the multiple disconnections.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF011 / SID304_V45_DF011 / SID301_V48_DF011 / SID304_V49_DF011 / SID304_V4D_DF011 / SID301_V4C_DF011
13B-85
MR-372-J84-13B050$429.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
*diff: differential
*temp: temperatureDF308
PRESENT
OR
STORED
CLOGGED PARTICLE FILTER
1. DEF: Signal outside upper limit
NOTESPriorities when dealing with a number of faults:
Deal with faults stored in the computer first.
Ask the customer about vehicle usage: driving style, type of journey, etc.
Conditions for applying the fault finding procedure to a stored fault:
The fault is declared present after the engine is started or following a road test.
Special notes:
If the fault is present:
– particle filter regeneration is inhibited,
– the EGR function is inhibited,
– the vehicle performance is reduced,
– the level 1 warning light is lit and a warning message (or light) is displayed on the
instrument panel.
Check that there are no leaks or blockages in the exhaust pipe,
Repair if necessary.
Carry out an After-Sales regeneration (before and after each regeneration, check the oil and diesel fuel levels).
Run command SC017 Particle filter regeneration (see Interpretation of commands).
Use ALP 21: Particle filter warning light lit.
Deal with the interpretation of fault DF1003 Particle filter differential pressure sensor circuit.
Check the exhaust system.
Deal with the interpretation of fault DF1000 Particle filter upstream temperature sensor circuit.
Deal with the interpretation of fault DF1007 Catalytic converter 1 downstream temperature sensor circuit.
Deal with the interpretation of fault DF999 Particle filter downstream temperature sensor circuit.
Deal with the interpretation of fault DF652 Turbine upstream temperature sensor circuit.
Carry out Te s t 1 0: Air Chain at the level of the turbocharger.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
Explain to the customer how the particle filter system works.
SID301_V44_DF308 / SID304_V45_DF308 / SID301_V48_DF308 / SID304_V49_DF308 / SID304_V4D_DF308 / SID301_V4C_DF308
13B-87
MR-372-J84-13B050$429.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
*diff: differential
*temp: temperatureDF311
PRESENT
OR
STORED
FAILED REGENERATIONS LIMIT EXCEEDED
1. DEF: Signal outside upper limit
NOTESPriorities when dealing with a number of faults:
Deal with faults stored in the computer first.
Conditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– the engine is started,
– a road test.
Special notes:
If the fault is present,
– particle filter regenerations when driving are inhibited.
Use the Ele. 1681 bornier for all operations on the engine management computer
connector.
Deal with the interpretation of fault DF308 Clogged particle filter.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF311 / SID304_V45_DF311 / SID301_V48_DF311 / SID304_V49_DF311 / SID304_V4D_DF311 / SID301_V4C_DF311
13B-105
MR-372-J84-13B050$468.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF953
PRESENT
OR
STOREDPARTICLE FILTER ABSENT
1. DEF: Signal outside lower limit
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after the engine is started or following a road test.
Priorities when dealing with a number of faults:
Deal with the following faults first: DF1003 Particle filter differential pressure
sensor circuit.
If the fault is present:
– smoke is emitted,
– the OBD warning light is lit.
Visually check the particle filter.
Check that the particle filter is in good condition.
Check that the exhaust is not broken or damaged.
Apply the interpretation of fault DF1003 Particle filter differential pressure sensor circuit.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF953 / SID304_V45_DF953 / SID301_V48_DF953 / SID304_V49_DF953 / SID304_V4D_DF953 / SID301_V4C_DF953
13B-114
MR-372-J84-13B050$468.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF1003
PRESENT
OR
STOREDPARTICLE FILTER DIFFERENTIAL PRESSURE SENSOR
CC.1 : Short circuit to + 12 V
CO.0 : Open circuit or short circuit to earth
1. DEF: Signal inconsistency
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after the engine is started or following a road test.
Special notes:
If the fault is present:
– the level 1 warning light is lit,
– the OBD warning light illuminates after three consecutive driving cycles
(starting + 5 seconds + switching off the ignition and waiting 1 minute).
– the particle filter fault finding procedure is inhibited,
– particle filter regeneration is inhibited.
Priorities when dealing with a number of faults:
Deal with fault DF011 Sensor supply voltage no. 1 first if it is present or stored.
Use CLIO III, MODUS, MEGANE II ph2, SCENIC II ph2 and Kangoo II Wiring
diagrams Technical Note.
Visually inspect the condition of the pressure pipes of the differential pressure sensor.
Check that they are sealed and in the correct position.
Check the connection and condition of the connector of the particle filter differential pressure sensor,
component code 1290 (see MR 392, 385, 364, 370 and 417, Mechanical, 19B, Exhaust, Particle filter
pressure sensor: Removal - Refitting).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the connection and condition of the injection computer connector, component code 120 (see MR 392,
385, 364, 370 and 417, Mechanical, 13B, Diesel injection, Diesel injection computer: Removal - Refitting).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the continuity, insulation and the absence of interference resistance on the following connections:
–3YD between components 1290 and 120,
–3AAM between components 1290 and 120,
–3TL between components 1290 and 120.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Connect a pressure gauge (fitted with a manual pump) to the sensor.
Vary the pressure between
0 and 1000 mbar and check that the value of parameter PR414 Particle filter
differential pressure is nearly identical.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF1003 / SID304_V45_DF1003 / SID301_V48_DF1003 / SID304_V49_DF1003 / SID304_V4D_DF1003 / SID301_V4C_DF1003
13B-187
MR-372-J84-13B050$663.mif
V17
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4C
Program No.: B1 and B2DIESEL INJECTION
Fault finding – Parameter summary table13B
Tool parameter Diagnostic tool title
PR125Power absorbed by the AC* compressor Vdiag 44 and 48 only
PR128First EGR valve offset
PR129Last EGR valve offset
PR130Cruise control setpoint
PR132Air flow
PR171Air flow setpoint for EGR Vdiag 44 and 48 only
PR190Engine idle speed setpoint.
PR224Turbocharging pressure sensor voltage Vdiag 44 and 48 only
PR228Injector control capacitor voltage
PR364Cylinder no. 1 fuel flow correction
PR365Cylinder no. 4 fuel flow correction
PR381Particle filter downstream temperature
Vdiag 4D, 45 and 49 only PR382Particle filter upstream temperature
PR383Weight of soot in the particle filter
PR391Mileage since particle filter replacement
PR400New EGR valve offset
PR405Cylinder no. 2 fuel flow correction
PR406Cylinder no. 3 fuel flow correction
PR412Mileage at last successful regeneration
Vdiag 4D, 45 and 49 only PR414Particle filter diff* pressure
PR415Time since last regeneration
PR513Mileage counter for level 1 warning light
PR514Mileage counter for level 2 warning light
PR634Air flow request
PR667Turbine upstream temperature
Vdiag 4D, 45 and 49 only PR668Turbine upstream temperature sensor voltage
PR669Particle filter diff* press* sens* voltage
PR670Particle filter upstream temp* sens* voltage
PR671Particle filter downstream temp* sens* voltage
PR672Damper valve position setpoint Vdiag 44 and 48 only
*AC: air conditioning system
*diff: differential*sens: sensor
*temp: temperature*press: pressure
13B-237
MR-372-J84-13B050$780.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of parameters
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
PR414
PARTICLE FILTER PRESSURE SENSOR
PARAMETER
DEFINITIONThis parameter indicates the particle filter differential pressure in mbar.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system
operation programming.
Conformity check with the engine stopped and the ignition on, or engine running, and engine coolant
temperature > 80°C
The differential pressure monitors the status of the particle weight in the filter.
The differential pressure of the particle filter is given in mbar.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
SID304_V4D_PR414/SID304_V45_PR414/SID304_V49_PR414/SID301_V4C_PR414
13B-244
MR-372-J84-13B050$780.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of parameters
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
*sens: sensor
*Circ: circuit
*diff: differential
*Press: PressurePR669
PARTICLE FILTER DIFF* PRESS* SENS* VOLTAGE
PARAMETER
DEFINITIONThis parameter indicates the voltage of the particle filter differential pressure sensor in
volts.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system
operation programming.
Conformity check with the engine stopped and the ignition on, or the engine running and the engine
coolant temperature > 80°C
PR669 ≈5V
In the event of a fault, consult the interpretation of DF1003 Particle filter differential pressure sensor circuit.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
SID304_V4D_PR669/SID304_V45_PR669/SID304_V49_PR669/SID301_V4C_PR669