13B-75V9 MR-372-J84-13B450$101.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF032
CONTINUED
Check the supply to thermoplunger 1:
– Disconnect the connector of component 898.
– Connect a test light between connection 3JB of component 898 and a chassis earth.
– Run command AC063 Thermoplunger no. 1 relay.
If the test light comes on correctly, measure the thermoplunger resistance between the connection 3JA of
component 898 and a chassis earth.
If the resistance is greater than 2Ω, replace thermoplunger 1.
If the test light does not come on, check the continuity and insulation of the following connection:
– Connection code 3JB between components 1550 and 898.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the earthing on the additional heater interface unit:
– Disconnect the connector of component 1550.
– Connect a test light between connections 3JA and BP27 of component 1550.
– Run command AC063 Thermoplunger no. 1 relay.
If the test light comes on correctly, replace the additional heater interface unit.
If the test light does not come on, check the continuity and insulation from + 12 V of the following connection:
– Connection code 3JA between components 120 and 1550.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 48, 58
13B-77V9 MR-372-J84-13B450$101.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF033
CONTINUED
Check the supply to thermoplungers 2 and 3:
– Disconnect the connector of component 1072.
– Connect a test light between connection 3JC of component 1072 and a chassis earth.
– Run command AC064 Thermoplunger no. 2 relay.
– Disconnect the connector of component 1073.
– Connect a test light between connection 3JD of component 1073 and a chassis earth.
– Run command AC064 Thermoplunger no. 2 relay.
If the test light comes on correctly, measure the resistance of thermoplunger 2 and 3 between the following
connections:
–3JC of component 1072 and a chassis earth,
–3JD of component 1073 and a chassis earth.
If the resistance is greater than 2 Ω, replace thermoplunger 2 or 3.
If the test light does not come on, check the continuity and insulation of the following connections:
– Connection code 3JC between components 1550 and 1072.
– Connection code 3JD between components 1550 and 1073.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the earthing on the additional heater interface unit:
– Disconnect the connector of component 1550.
– Connect a test light between connections 3JAA and BP27 of component 1550.
– Run command AC064 Thermoplunger no. 2 relay.
If the test light comes on correctly, replace the additional heater interface unit.
If the test light does not come on, check the continuity and insulation from + 12 V of the following connection:
– Connection code 3JAA between components 120 and 1550.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 48, 58
13B-79V9 MR-372-J84-13B450$102.mif
13B
DF034
CONTINUED
Check the supply to thermoplunger 4:
– Disconnect the connector of component 1074.
– Connect a test light between connection 3JAC of component 1074 and a chassis earth.
– Run command AC031 Thermoplunger relay no.3.
If the test light illuminates correctly, measure the resistance of the thermoplunger 4 between the following
connection:
–3JAC of component 1074 and a chassis earth,
If the resistance is greater than 2Ω, replace thermoplunger 4.
If the test light does not come on, check the continuity and insulation of the following connection:
– Connection code 3JAC between components 1550 and 1074.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the earthing on the additional heater interface unit:
– Disconnect the connector of component 1550.
– Connect a test light between connections 3JAB and BP27 of component 1550.
– Run command AC031 Thermoplunger relay no.3.
If the test light comes on correctly, replace the additional heater interface unit.
If the test light does not come on, check the continuity and insulation from + 12 V of the following connection:
– Connection code 3JAB between components 120 and 1550.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
DIESEL INJECTION
Fault finding – Interpretation of faults
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 48, 58
13B-80V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF038
PRESENT
OR
STOREDCOMPUTER
1.DEF: Internal electronic fault
2.DEF: Voltage too low
3.DEF: Data inconsistency
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– starting the engine,
– a road test.
Special notes:
If the fault is present:
– depending on the situation, the level 1 or level 2 warning light is lit for 1.DEF,
–the level 1 warning light comes on for 3.DEF,
–the level 2 warning light comes on for 2.DEF,
– increase in polluting emissions,
– injection cut-off in defect mode,
– the engine stops.
Use bornier Elé. 1681 for all operations on the engine management computer
connectors.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
1.DEF
NOTESNone.
If the fault is stored, clear the fault from the computer memory.
Switch off the ignition, wait for the end of the power latch, then switch the ignition back on. Start the engine and re-
establish dialogue.
If the fault is still present, contact the Techline.
EDC16C36_V44_DF038/EDC16C36_V4C_DF038/EDC16C36_V48_DF038/EDC16C36_V50_DF038/EDC16C36_V54_DF038/
EDC16C36_V58_DF038
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
13B-86V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF053
PRESENT
OR
STOREDRAIL PRESSURE REGULATION FUNCTION1.DEF: Above maximum threshold.
2.DEF: Negative loop deviation.
3.DEF: Positive loop deviation.
4.DEF: Below minimum threshold.
NOTESOrder of priority for a combination of faults:
Deal with fault DF643 Rail pressure regulator circuit first if it is present or stored.
Conditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– the engine is started,
– a road test.
Special notes:
If the fault is present:
– engine torque limited for 2.DEF/3.DEF,
–the level 1 warning light comes on for 2DEF/3.DEF.
–the level 2 warning light comes on for 1.DEF/3.DEF/4.DEF,
– engine stops for 1.DEF/3.DEF/4.DEF.
Use bornier Elé.1681 for any operations on the injection computer connectors.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
EDC16C36_V44_DF053/EDC16C36_V4C_DF053/EDC16C36_V48_DF053/EDC16C36_V50_DF053/EDC16C36_V54_DF053/
EDC16C36_V58_DF053
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
13B-88V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF054
PRESENT
OR
STOREDTURBOCHARGING SOLENOID VALVE CONTROL CIRCUITCO: Open circuit
CC.1: short-circuit to + 12 V
CC.0: Short circuit to earth
1.DEF: Internal electronic fault
NOTESPriorities when dealing with a number of faults:
Deal with fault DF046 Battery voltage first, if it is present or stored.
Conditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– the ignition is switched on.
– starting the engine,
– a road test,
– actuator command AC004 Turbocharging solenoid valve.
Special notes:
If the fault is present:
– turbocharging is no longer authorised,
– the EGR function is inhibited,
–the level 1 and European On Board Diagnostic warning lights are lit.
Use bornier Elé.1681 for any operations on the injection computer connectors.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
EDC16C36_V44_DF054/EDC16C36_V4C_DF054/EDC16C36_V48_DF054/EDC16C36_V50_DF054/EDC16C36_V54_DF054/
EDC16C36_V58_DF054
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
13B-93V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF055
PRESENT
OR
STOREDTURBOCHARGING PRESSURE REGULATION CIRCUIT
1.DEF: Turbocharging pressure too high
2.DEF: Turbocharging pressure too low
NOTESPriorities when dealing with a number of faults:
Deal with faults DF054 Turbocharger solenoid valve control circuit and DF004
Turbocharging pressure sensor circuit first, if they are present or stored.
Conditions for applying the fault finding procedure to a stored fault:
In the negative loop difference phase.
The fault is declared present after:
– the ignition is switched on.
– starting the engine,
– a road test.
Special notes:
If the fault is present:
– engine torque limited,
– turbocharging regulation is inhibited,
– the EGR function is inhibited,
– increase in polluting emissions,
– activation of the EGR bypass,
– the injection level 1 warning light is on.
Use bornier Elé.1681 for any operations on the injection computer connectors.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
EDC16C36_V44_DF055/EDC16C36_V4C_DF055/EDC16C36_V48_DF055/EDC16C36_V50_DF055/EDC16C36_V54_DF055/
EDC16C36_V58_DF055
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
13B-95V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF056
PRESENT
OR
STOREDAIR FLOW SENSOR CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short circuit + 12 volts
1.DEF: Value outside permitted tolerance values
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– the ignition is switched on.
– starting for CC.1 and continuously for CO.0,
– a road test,
– the ignition is switched off: 1.DEF
Special notes:
If the fault is present:
–the level 1 warning light is lit,
– the EGR function is inhibited,
Use bornier Elé. 1681 for all operations on the engine management computer
connectors.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
EDC16C36_V44_DF056/EDC16C36_V4C_DF056/EDC16C36_V48_DF056/EDC16C36_V50_DF056/EDC16C36_V54_DF056/
EDC16C36_V58_DF056
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58