13B-107
MR-372-J84-13B200$324.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF118
PRESENT
OR
STOREDEGR SOLENOID VALVE SERVO-CONTROL
1.DEF: Insufficient EGR valve flow.
2.DEF: Excessive EGR valve flow.
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after the engine is started or following a road test.
Special notes:
If the fault is present the EGR function is disabled.
If 1.DEF is present, the level 1 warning light is lit.
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors.
Priority when dealing with a number of faults:
–DF272 EGR valve control circuit if it is present or stored.
IMPORTANT
This fault can result in a rapid and significant fouling of the particle filter.
If dealing with this fault requires the EGR valve to be replaced, run command SC036
Reinitialise programming and select EGR valve to reinitialise the EGR valve offsets
(see Replacement of components).
Check the EGR valve connections.
Check the injection computer connections.
Repair if necessary.
Check for continuity and absence of interference resistance of the following connections:
- connection code 3VP,
- connection code 3VQ.
between components 120 and 1460.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check that there are no leaks on the EGR circuit, pierced or damaged pipes, and the tightness of the clips.
Measure the resistance of the EGR valve motor between connections 3VP and 3VQ.
Replace the EGR valve if the resistance displayed is not between 1 Ω < X < 400 Ω at 20°C.
If the valve is jammed or irrevocably seized, replace the EGR valve.
Run command SC036 Reinitialise programming and select EGR valve to reinitialise the EGR valve offsets (see
Replacement of components).
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF118/EDC16_V58_DF118/EDC16_V5C_DF118/EDC16_V18_DF118/EDC16_V1C_DF118/EDC16_V20_DF118
13B-108
MR-372-J84-13B200$324.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF167
PRESENT
OR
STOREDTHERMOPLUNGER RELAY CIRCUIT
1.DEF: Below minimum threshold
NOTESDeal with the following faults first:
For MEGANE II ph1 and ph2, SCENIC II ph1 and ph2:
–DF032 Thermoplunger 1 relay control circuit,
–DF033 Thermoplunger 2 relay control circuit,
–DF034 Thermoplunger 3 relay control circuit,
For LAGUNA II ph2:
–DF238 Thermoplunger no. 3 relay circuit,
–DF239 Thermoplunger no. 2 relay circuit,
–DF240 Thermoplunger no. 1 relay circuit.
Conditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– with the engine running,
– using SC017 Particle filter regeneration,
– actuation of the thermoplunger using AC063 Thermoplunger relay no.1, AC064
Thermoplunger relay no.2, AC031 Thermoplunger relay no.3,
– the appearance of at least two of faults DF032 Thermoplunger relay control
circuit 1, DF033 Thermoplunger relay control circuit 2, DF034 Thermoplunger
relay control circuit 3.
Use the Wiring Diagrams Technical Notes for MEGANE II ph1 and ph2, SCENIC II
ph1 and ph2 and LAGUNA II ph2.
Visually inspect the connectors, fitting and correct operation of the thermoplunger, component codes: 898, 1072,
1073 and 1074.
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair) repair the connector(s); otherwise, replace the wiring.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF167/EDC16_V58_DF167/EDC16_V5C_DF167/EDC16_V18_DF167/EDC16_V1C_DF167/EDC16_V20_DF167
13B-110
MR-372-J84-13B200$324.mif
V13
13B
DIESEL INJECTION
Fault finding – Interpretation of faults
DF176
PRESENT
OR
STOREDLOW-SPEED FAN ASSEMBLY CIRCUIT
CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: Inconsistent signal
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– an attempted start, or with engine running,
– command AC038 Low-speed fan assembly relay is run.
Special notes:
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors.
CO
NOTESNone.
Check the + 12 V after relay supply to the relay mounting R09 on connection 3FB.
Check the condition of the connections and the correct operation of the running lights relay.R09
Replace it if necessary.
Check the continuity and absence of interference resistance on connection 3JN between components 120
and 597.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
CC.0
NOTESNone.
Check the continuity and insulation to earth of connection 3FB between components 983 and 700.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V18_DF176/EDC16_V1C_DF176/EDC16_V20_DF176EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20
13B-111
MR-372-J84-13B200$324.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20
13B
DF176
CONTINUED
CC.1
NOTESNone.
Check the continuity and insulation from + 12 V of connection 3JN between components 597 and 120.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
1. DEF
NOTESNone.
Check the condition of the connections:
– on the low-speed fan unit relay connector,
– on the injection computer grey connector C.
Repair if necessary.
Check the continuity and absence of interference resistance between the following connections:
– connection code 3JN between components 120 and 597.
– connection code 3FB between components 983 and 700.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
13B-112
MR-372-J84-13B200$324.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20
13B
DF177
PRESENT
OR
STOREDHIGH-SPEED FAN ASSEMBLY CIRCUIT
CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: Inconsistent signal
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– an attempted start, or with engine running,
– command AC039 High-speed fan unit run.
Special notes:
Use bornier Elé. 1681 for all operations on the injection computer connectors.
CO
NOTESNone.
Check the + 12 V after relay supply to the fan assembly relay mounting R10 on connection 3FB.
Check the condition of the connections and the correct operation of the relay.R10
Replace the relay if necessary.
Check the continuity and the absence of interference resistance of connection 3JP between components 120
and 597.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
CC.0
NOTESNone.
Check the continuity and insulation to earth of connection 3FB between components 120 and 983.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V18_DF177/EDC16_V1C_DF177/EDC16_V20_DF177
13B-113
MR-372-J84-13B200$324.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20
13B
DF177
CONTINUED
CC.1
NOTESNone.
Check the continuity and insulation from + 12 V of connection 3JP between components 120 and 597.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
1. DEF
NOTESNone.
Check the condition of the connections:
– of the R10 fan assembly relay connector,
– on the injection computer grey connector C.
Repair if necessary.
Check the continuity and absence of interference resistance between the following connections:
– connection code 3JP,
– connection code 3FB,
Between components 120 and 597.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
13B-114
MR-372-J84-13B200$324.mif
V13
13B
DIESEL INJECTION
Fault finding – Interpretation of faults
DF195
PRESENT
OR
STOREDENGINE SPEED/CAMSHAFT SENSOR CONSISTENCY
1.DEF: Signal incoherent
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault becomes present after an attempt to start.
Special notes:
If the fault is stored, clear the fault from the computer memory.
Switch off the ignition, start the engine and check that the fault does not reappear.
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors.
Check the engine speed sensor and camshaft sensor connections.
Check the injection computer connections.
Repair if necessary.
With the connector disconnected, check the continuity and absence of interference resistance on the
following connections:
– connection code 3FJ,
– connection code 3CQ,
between components 120 and 746.
– connection code 3BG,
– connection code 3BL.
between components120 and 149.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
With the ignition on and the camshaft sensor connected:
Use a voltmeter to measure the voltage between connections 3FJ and 3FB or 3FB1 of the camshaft sensor:
The voltage displayed should be equal to the battery voltage ± 0.08 V.
– If the voltage is outside permitted tolerance values, take the measurement again on the connector, with the
camshaft sensor disconnected,
– If the voltage is still outside permitted tolerance values with the sensor disconnected:
Check the continuity and absence of interference resistance on connection 3FB or 3FB1 between
components 746 and 1337 or 983.
If the voltage measured is correct, with the sensor disconnected:
Measure the resistance of the camshaft sensor between connections 3CQ and 3FB or 3FB1.
Replace the sensor if its resistance is not 9750 Ω < X < 10750 Ω at 20°C
Check that the engine speed sensor is correctly mounted and that the flywheel target is not damaged.
Check that the engine speed sensor – flywheel air gap is correct: 0.5 mm < X < 1.8 mm.
Measure the resistance of the engine speed sensor between connections 3BG and 3BL.
Replace the sensor if its resistance is not 510 Ω < X < 850 Ω at 20°C.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF195/EDC16_V58_DF195/EDC16_V5C_DF195/EDC16_V18_DF195/EDC16_V1C_DF195/EDC16_V20_DF195EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B-115
MR-372-J84-13B200$324.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF209
PRESENT
OR
STOREDEGR POSITION SENSOR CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: Micro-breaks
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine is started or following a road test.
Special notes:
If the fault is present:
– there is smoke coming from the exhaust,
– the EGR offset fault finding function is disabled,
– the OBD warning light illuminates after three consecutive driving cycles (starting
+ 5 seconds + switch off the ignition and wait 1 minute).
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors.
Priorities when dealing with a number of faults:
–DF012 Sensor supply voltage no. 2 if it is present or stored.
IMPORTANT
This fault can result in a rapid and significant fouling of the particle filter.
If dealing with this fault requires the EGR valve to be replaced, run command SC036
Reinitialise programming and select EGR valve to reinitialise the EGR valve offsets
(see Replacement of components).
WARNING
This fault may appear if the wiring harness has been damaged.
Follow the procedure described in the Wiring Check in the Introduction.
This check enables the condition and the conformity of the engine wiring harness to be checked.
CO.0
NOTESNone
Check the EGR valve connections.
Check the injection computer connections.
Repair if necessary.
Check the continuity and insulation to earth of the following connections:
– connection code 3EL,
– connection code 3GC.
between components 120 and 1460.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF209/EDC16_V58_DF209/EDC16_V5C_DF209/EDC16_V18_DF209/EDC16_V1C_DF209/EDC16_V20_DF209