DTC P0442 EVAP CONTROL SYSTEMEC-817
< SERVICE INFORMATION > [MR18DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
OK or NG
OK >> GO TO 3.
NG >> 1. Open fuel filler cap, then clean cap and fuel filler neck threads using air blower.
2. Retighten until reteaching sound is heard.
3.CHECK FUEL FILLER CAP FUNCTION
Check for air releasing sound while opening the fuel filler cap.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4.CHECK FUEL TANK VACUUM RELIEF VALVE
Refer to EC-528, "
Component Inspection".
OK or NG
OK >> GO TO 5.
NG >> Replace fuel filler cap with a genuine one.
5.INSTALL THE PRESSURE PUMP
To locate the EVAP leak, install EVAP service port adapter and pressure pump to EVAP service port securely.
For the location of EVAP service port (2), refer to EC-526, "
Descrip-
tion".
• EVAP canister purge volume control solenoid valve (1)
• : Vehicle front
NOTE:
Improper installation of the EV AP service port adapter to the
EVAP service port may cause leaking.
With CONSULT-III>>GO TO 6.
Without CONSULT-III>>GO TO 7.
6.CHECK FOR EVAP LEAK With CONSULT-III
1. Turn ignition switch ON.
2. Select “EVAP SYSTEM CLOSE” of “WORK SUPPORT” mode with CONSULT-III.
3. Touch “START” and apply pressure into the EVAP line until the pressure indicator reaches the middle of the bar graph.
CAUTION:
• Never use compressed air or a high pressure pump.
• Do not exceed 4.12 kPa (0.042 kg/cm
2, 0.6 psi) of pressure in the system.
BBIA0703E
SEF916U
Revision: May 2010 2011 Versa
EC-818
< SERVICE INFORMATION >[MR18DE]
DTC P0442 EVAP CONTROL SYSTEM
4. Using EVAP leak detector, locate the EVAP leak. For the leak
detector, refer to the instruction manual for more details.
Refer to EC-526, "
Description".
OK or NG
OK >> GO TO 8.
NG >> Repair or replace.
7.CHECK FOR EVAP LEAK
Without CONSULT-III
1. Turn ignition switch OFF.
2. Apply 12 volts DC to EVAP canister vent control valve. The
valve will close. (Continue to appl y 12 volts until the end of test.)
- EVAP control system pressure sensor (1)
- EVAP canister (2)
- EVAP canister vent control valve (3)
3. Pressurize the EVAP line using pressure pump with 1.3 to 2.7
kPa (10 to 20 mmHg, 0.39 to 0.79 inHg), then remove pump and
EVAP service port adapter.
CAUTION:
• Never use compressed air or a high pressure pump.
• Do not exceed 4.12 kPa (0.042 kg/cm
2, 0.6 psi) of pressure
in the system.
4. Using EVAP leak detector, locate the EVAP leak. For the leak detector, refer to the instruction manual for more details. Refer
to EC-526, "
Description".
OK or NG
OK >> GO TO 8.
NG >> Repair or replace.
8.CHECK DRAIN FILTER
Refer to EC-821, "
Component Inspection".
OK or NG
OK >> GO TO 9.
NG >> Replace drain filter.
9.CHECK EVAP CANISTER VENT CONTROL VALVE
Check the following,
• EVAP canister vent control valve is installed properly. Refer to FL-16, "
Removal and Installation (MR18DE)".
• EVAP canister vent control valve.
Refer to EC-840, "
Component Inspection".
OK or NG
OK >> GO TO 10.
NG >> Repair or replace EVAP cani ster vent control valve and O-ring.
10.CHECK IF EVAP CANISTER SATURATED WITH WATER
SEF200U
BBIA0693E
SEF200U
Revision: May 2010 2011 Versa
DTC P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-823
< SERVICE INFORMATION > [MR18DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
On Board Diagnosis LogicINFOID:0000000006341987
DTC Confirmation ProcedureINFOID:0000000006341988
Perform PROCEDURE FOR MALFUNCTION A first.
If the DTC cannot be confirmed,
perform PROCEDURE FOR MALFUNCTION B.
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
PROCEDURE FOR MALFUNCTION A
TESTING CONDITION:
• Perform "DTC Confirmation Procedure" when the fuel le vel is between 1/4 and 3/4 full, and vehicle is placed
on flat level surface.
• Always perform test at a temperature of 5 to 60° C (41 to 140°F).
• Cool the vehicle so that engine coolant temperat ure becomes same level as ambient temperature.
With CONSULT-III
1. Turn ignition switch ON and select "DATA MONITOR" mode with CONSULT-III.
2. Check that the following condition are met.
FUEL T/TMP SE: 0 – 35 °C (32 – 95° F)
3. Start engine and wait at least 60 seconds.
4. Check 1st trip DTC.
5. If 1st trip DTC is detected, go to EC-826, "
Diagnosis Procedure".
With GST
1. Turn ignition switch ON.
2. Set voltmeter probes to ECM terminal 43 (FTT sensor signal)
and ground.
3. Check that the voltage is 3.1 – 4.2 V.
4. Start engine and wait at least 60 seconds.
5. Check 1st trip DTC.
6. If 1st trip DTC is detected, go to EC-826, "
Diagnosis Procedure".
PROCEDURE FOR MALFUNCTION B
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Always perform test at a temperature of 5 °C (41° F) or more.
With CONSULT-III
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0443
0443 EVAP canister purge
volume control solenoid
valve A)
The canister purge flow is detected during
the vehicle is stopped while the engine is
running, even when EVAP canister purge
volume control solenoid valve is completely
closed. • EVAP control system pressure sensor
• EVAP canister purge volume control so-
lenoid valve
(EVAP canister purge volume control so-
lenoid valve is stuck open.)
• EVAP canister vent control valve
• Drain filter
• EVAP canister
• Hoses (Hoses are connected incorrectly or
clogged.)
B)
The canister purge flow is detected during
the specified driving conditions, even when
EVAP canister purge volume control sole-
noid valve is completely closed.
PBIB0679E
Revision: May 2010
2011 Versa
EC-824
< SERVICE INFORMATION >[MR18DE]
DTC P0443 EVAP CANISTER PURGE VO
LUME CONTROL SOLENOID VALVE
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON.
4. Select “PURG VOL CN/V P1444” of “EVAPORATIVE SYSTEM” in “DTC WORK SUPPORT” mode with
CONSULT-III.
5. Touch “START”.
6. Start engine and let it idle until “TESTING” on CONSULT-III changes to “COMPLETED”. (It will take approximately 10 seconds.)
If “TESTING” is not displayed after 5 minutes, retry from step 2.
7. Make sure that “OK” is displayed after touching “ SELF-DIAG RESULTS”. If “NG” is displayed, refer to EC-
826, "Diagnosis Procedure".
With GST
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engine and let it idle for at least 20 seconds.
4. Select Service $07 with GST.
5. If 1st trip DTC is detected, go to EC-826, "
Diagnosis Procedure".
Revision: May 2010 2011 Versa
EC-826
< SERVICE INFORMATION >[MR18DE]
DTC P0443 EVAP CANISTER PURGE VO
LUME CONTROL SOLENOID VALVE
Do not use ECM ground terminals when measuring input/output voltage. Doi ng so may result in dam-
age to the ECM's transistor. Use a ground ot her than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)
Diagnosis ProcedureINFOID:0000000006341990
1.CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect EVAP canister purge volume control solenoid valve (1) harness connector.
- EVAP service port (2)
- : Vehicle front
3. Turn ignition switch ON.
TERMI-
NAL
NO. WIRE
COLOR ITEM
CONDITION DATA (DC Voltage)
9P EVAP canister purge volume
control solenoid valve [Engine is running]
• Idle speed
• Accelerator pedal: Not depressed even
slightly, after engine starting. BATTERY VOLTAGE
(11 - 14 V)
[Engine is running]
• Engine speed: About 2,000 rpm (More than 100 seconds after starting engine) Approximately 10 V
32 P ECM relay
(Self shut-off) [Engine is running]
[Ignition switch: OFF]
• For a few seconds after turning ignition
switch OFF 0 - 1.0 V
[Ignition switch: OFF]
• More than a few seconds after turning ig- nition switch OFF BATTERY VOLTAGE
(11 - 14 V)
105 G Power supply for ECM [Ignition switch: ON] BATTERY VOLTAGE
(11 - 14 V)
PBIB0050E
PBIB0520E
BBIA0703E
Revision: May 2010 2011 Versa
DTC P0443 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
EC-827
< SERVICE INFORMATION > [MR18DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
4. Check voltage between EVAP canister purge volume control
solenoid valve terminal 1 and ground with CONSULT-III or
tester.
OK or NG
OK >> GO TO 3.
NG >> GO TO 2.
2.DETECT MALFUNCTIONING PART
Check the following.
• Harness connectors E8, F8
• Harness for open or short between EVAP canister purge volume control solenoid valve and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors.
3.CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT
FOR OPEN AND SHORT1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 9 and EVAP canister purge volume control solenoid valve terminal 2. Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 4.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
4.CHECK EVAP CONTRO L SYSTEM PRESSURE SENSOR CONNECTOR
1. Disconnect EVAP control system pressure sensor harness con-
nector.
- EVAP control system pressure sensor (1)
- EVAP canister (2)
- EVAP canister vent control valve (3)
2. Check connectors for water.
OK or NG
OK >> GO TO 5.
NG >> Replace EVAP control system pressure sensor.
5.CHECK EVAP CONTROL SYS TEM PRESSURE SENSOR
Refer to EC-850, "
Component Inspection".
OK or NG
OK (With CONSULT-III)>>GO TO 6.
OK (Without CONSULT-III)>>GO TO 7.
NG >> Replace EVAP control system pressure sensor.
6.CHECK EVAP CANISTER PURGE VO LUME CONTROL SOLENOID VALVE
With CONSULT-III
1. Turn ignition switch OFF.
2. Reconnect harness connectors disconnected.
3. Start engine. Voltage: Battery voltage
PBIB0080E
Continuity should exist.
Water should not exist.
BBIA0693E
Revision: May 2010
2011 Versa
DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE
EC-831
< SERVICE INFORMATION > [MR18DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
On Board Diagnosis LogicINFOID:0000000006341995
DTC Confirmation ProcedureINFOID:0000000006341996
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confi
rm battery voltage is more than 11 V at idle.
1. Start engine and let it idle for at least 13 seconds.
2. Check 1st trip DTC.
3. If 1st trip DTC is detected, go to EC-833, "
Diagnosis Procedure".
DTC No. Trouble diagnosis name DTC detecting conditionPossible cause
P0444
0444 EVAP canister purge volume
control solenoid valve circuit
open An excessively low voltage signal is sent
to ECM through the valve • Harness or connectors
(EVAP canister purge volume control
solenoid valve circuit is open or short-
ed.)
• EVAP canister purge volume control so- lenoid valve
P0445
0445 EVAP canister purge volume
control solenoid valve circuit
shorted An excessively high voltage signal is sent
to ECM through the valve • Harness or connectors
(EVAP canister purge volume control
solenoid valve circuit is shorted.)
• EVAP canister purge volume control so-
lenoid valve
Revision: May 2010 2011 Versa
DTC P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE
EC-833
< SERVICE INFORMATION > [MR18DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
Do not use ECM ground terminals wh
en measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground ot her than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)
Diagnosis ProcedureINFOID:0000000006341998
1.CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect EVAP canister purge volume control solenoid valve (1) harness connector.
- EVAP canister port (2)
3. Turn ignition switch ON.
TERMI-
NAL
NO. WIRE
COLOR ITEM
CONDITION DATA (DC Voltage)
9P EVAP canister purge volume
control solenoid valve [Engine is running]
• Idle speed
• Accelerator pedal: Not depressed even
slightly, after engine starting. BATTERY VOLTAGE
(11 - 14 V)
[Engine is running]
• Engine speed: About 2,000 rpm (More than 100 seconds after starting engine) Approximately 10 V
32 P ECM relay
(Self shut-off) [Engine is running]
[Ignition switch: OFF]
• For a few seconds after turning ignition
switch OFF 0 - 1.0 V
[Ignition switch: OFF]
• More than a few seconds after turning ig- nition switch OFF BATTERY VOLTAGE
(11 - 14 V)
105 G Power supply for ECM [Ignition switch: ON] BATTERY VOLTAGE
(11 - 14 V)
PBIB0050E
PBIB0520E
BBIA0693E
Revision: May 2010 2011 Versa