Page 1605 of 5598
AUTOMATIC BACK DOOR SYSTEMDLK-69
< WIRING DIAGRAM >
C
DE
F
G H
I
J
L
M A
B
DLK
N
O P
JCKWM4448GB
Revision: 2010 May2011 QX56
Page 1606 of 5598
DLK-70
< WIRING DIAGRAM >
AUTOMATIC BACK DOOR SYSTEM
JCKWM4449GB
Revision: 2010 May2011 QX56
Page 1607 of 5598
AUTOMATIC BACK DOOR SYSTEMDLK-71
< WIRING DIAGRAM >
C
DE
F
G H
I
J
L
M A
B
DLK
N
O P
JCKWM4450GB
Revision: 2010 May2011 QX56
Page 1608 of 5598
DLK-72
< WIRING DIAGRAM >
AUTOMATIC BACK DOOR SYSTEM
JCKWM4451GB
Revision: 2010 May2011 QX56
Page 1609 of 5598
AUTOMATIC BACK DOOR SYSTEMDLK-73
< WIRING DIAGRAM >
C
DE
F
G H
I
J
L
M A
B
DLK
N
O P
JCKWM4452GB
Revision: 2010 May2011 QX56
Page 1610 of 5598
DLK-74
< WIRING DIAGRAM >
AUTOMATIC BACK DOOR SYSTEM
JCKWM4453GB
Revision: 2010 May2011 QX56
Page 1616 of 5598

DLK-80
< BASIC INSPECTION >
INSPECTION AND ADJUSTMENT
INSPECTION AND ADJUSTMENT
ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL
ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : De-
scription
INFOID:0000000006225867
When the battery is disconnected from the negative terminal, it is necessary to perform initial setting to oper-
ate automatic back door control system normally.
NOTE:
The following specified operations are not performed under the non-initialized condition.
Automatic back door open/close function
Anti-pinch function
ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : Work
Procedure
INFOID:0000000006225868
1.INITIALIZATION
1. Fully close the back door manually. (when back door is already fully closed, this operation is not neces-
sary)
2. Perform automatic back door open/close operation of back door.
3. Check for noise or malfunctioning during operation.
4. Check that hazard lamp blinks and that warning buzzer operates.
NOTE:
Never touch back door, or allow foreign materials to be pinched in door, when performing automatic back door
open/close operation of back door, until it is in the fully closed or fully open position.
>> WORK END
ADDITIONAL SERVICE WHEN RE PLACING CONTROL UNIT (BCM)
ADDITIONAL SERVICE WHEN REPLACIN G CONTROL UNIT (BCM) : Description
INFOID:0000000006225869
Perform the system initialization when replacing BCM, replacing Intelligent Key or registering an additional
Intelligent Key.
ADDITIONAL SERVICE WHEN REPLACIN G CONTROL UNIT (BCM) : Work Proce-
dure
INFOID:0000000006225870
Refer to the CONSULT-III operation manual for the initialization procedure.
ADDITIONAL SERVICE WHEN REPLAC ING (AUTOMATIC BACK DOOR CON-
TROL MODULE)
ADDITIONAL SERVICE WHEN REPLACIN G (AUTOMATIC BACK DOOR CONTROL
MODULE) : Description
INFOID:0000000006225871
When replacing control module, or removing connector termi nal, it is necessary to perform initial setting to
operate automatic back door system normally.
NOTE:
The following specified operations are not performed under the non-initialized condition.
Automatic back door open/close function
Anti-pinch function
ADDITIONAL SERVICE WHEN REPLACIN G (AUTOMATIC BACK DOOR CONTROL
MODULE) : Work Procedure
INFOID:0000000006225872
1.INITIALIZATION
Revision: 2010 May2011 QX56
Page 1617 of 5598
INSPECTION AND ADJUSTMENTDLK-81
< BASIC INSPECTION >
C
DE
F
G H
I
J
L
M A
B
DLK
N
O P
1. Fully close the back door manually. (when back door is already fully closed, this operation is not neces-
sary)
2. Perform automatic back door open/close operation of back door.
3. Check for noise or malfunctioning during operation.
4. Check that hazard lamp blinks and that warning buzzer operates.
NOTE:
Never touch back door, or allow foreign materials to be pinched in door, when performing automatic back door
open/close operation of back door, until it is in the fully closed or fully open position.
>> WORK END
Revision: 2010 May2011 QX56